Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test

被引:39
作者
Muller, Bart
Hofbauer, Marcus
Rahnemai-Azar, Amir Ata
Wolf, Megan
Araki, Daisuke
Hoshino, Yuichi
Araujo, Paulo
Debski, Richard E.
Irrgang, James J.
Fu, Freddie H.
Musahl, Volker [1 ]
机构
[1] Univ Pittsburgh, Orthopaed Robot Lab, Dept Orthopaed Surg, Pittsburgh, PA 15260 USA
关键词
anterior cruciate ligament; pivot shift test; knee; kinematics;
D O I
10.1080/10255842.2015.1006210
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 +/- 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 +/- 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 458. Average percent error during anterior translation of the lateral knee compartment of 6 mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.
引用
收藏
页码:217 / 228
页数:12
相关论文
共 31 条
[1]   Comparison of three non-invasive quantitative measurement systems for the pivot shift test [J].
Araujo, Paulo H. ;
Ahlden, Mattias ;
Hoshino, Yuichi ;
Muller, Bart ;
Moloney, Gele ;
Fu, Freddie H. ;
Musahl, Volker .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (04) :692-697
[2]   Lateral compartment translation predicts the grade of pivot shift: a cadaveric and clinical analysis [J].
Bedi, Asheesh ;
Musahl, Volker ;
Lane, Clayton ;
Citak, Musa ;
Warren, Russell F. ;
Pearle, Andrew D. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (09) :1269-1276
[3]   Clinical relevance of static and dynamic tests after anatomical double-bundle ACL reconstruction [J].
Bignozzi, Simone ;
Zaffagnini, Stefano ;
Lopomo, Nicola ;
Fu, Freddie H. ;
Irrgang, James J. ;
Marcacci, Maurilio .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (01) :37-42
[4]  
Branch TP, 2010, KNEE SURG SPORT TR A, V18, P1379, DOI 10.1007/s00167-009-1010-y
[5]   Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament [J].
Bull, AMJ ;
Earnshaw, PH ;
Smith, A ;
Katchburian, MV ;
Hassan, ANA ;
Amis, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :1075-1081
[6]   A mechanized and standardized pivot shifter: technical description and first evaluation [J].
Citak, Musa ;
Suero, Eduardo M. ;
Rozell, Joshua C. ;
Bosscher, Marianne Roberta Frederiek ;
Kuestermeyer, Julian ;
Pearle, Andrew D. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (05) :707-711
[7]   Evaluation of a simulated pivot shift test: a biomechanical study [J].
Engebretsen, Lars ;
Wijdicks, Coen A. ;
Anderson, Colin J. ;
Westerhaus, Benjamin ;
LaPrade, Robert F. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (04) :698-702
[8]  
GALWAY HR, 1980, CLIN ORTHOP RELAT R, P45
[9]   In vivo measurement of the pivot-shift test in the anterior Cruciate ligament-deficient knee using an electromagnetic device [J].
Hoshino, Yuichi ;
Kuroda, Ryosuke ;
Nagamune, Kouki ;
Yagi, Masayoshi ;
Mizuno, Kiyonori ;
Yamaguchi, Motoi ;
Muratsu, Hirotsugu ;
Ybshiya, Shinichi ;
Kurosaka, Masahiro .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (07) :1098-1104
[10]   Quantitative evaluation of the pivot shift by image analysis using the iPad [J].
Hoshino, Yuichi ;
Araujo, Paulo ;
Ahlden, Mattias ;
Samuelsson, Kristian ;
Muller, Bart ;
Hofbauer, Marcus ;
Wolf, Megan R. ;
Irrgang, James J. ;
Fu, Freddie H. ;
Musahl, Volker .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (04) :975-980