Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography

被引:166
作者
Rubin, GD [1 ]
Shiau, MC [1 ]
Leung, AN [1 ]
Kee, ST [1 ]
Logan, LJ [1 ]
Sofilos, MC [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
aneurysm; aorta; CT; dissection; computed tomography (CT); angiography; comparative studies; helical; technology;
D O I
10.1148/radiology.215.3.r00jn18670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography. MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material). RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds). CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 21 条
[1]   Aortic aneurysmal disease: Assessment of stent-graft treatment - CT versus conventional angiography [J].
Armerding, MD ;
Rubin, GD ;
Beaulieu, CF ;
Slonim, SM ;
Olcott, EW ;
Samuels, SL ;
Jorgensen, MJ ;
Semba, CP ;
Jeffrey, RB ;
Dake, MD .
RADIOLOGY, 2000, 215 (01) :138-146
[2]   SPIRAL CT ANGIOGRAPHY [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
MALI, WPTM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1273-1278
[3]   High-resolution three-dimensional imaging from subsecond helical CT data sets: Applications in vascular imaging [J].
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :441-443
[4]   Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector [J].
Hopper, KD ;
Mosher, TJ ;
Kasales, CJ ;
TenHave, TR ;
Tully, DA ;
Weaver, JS .
RADIOLOGY, 1997, 205 (01) :269-271
[5]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[6]   Renal artery stenosis: Detection and quantification with spiral CT angiography versus optimized digital subtraction angiography [J].
Kaatee, R ;
Beek, FJA ;
deLange, EE ;
vanLeeuwen, MS ;
Smits, HFM ;
vanderVen, PJG ;
Beutler, JJ ;
Mali, WPTM .
RADIOLOGY, 1997, 205 (01) :121-127
[7]   Detection and follow-up of important extra-arterial lesions with helical CT angiography [J].
Katz, DS ;
Jorgensen, MJ ;
Rubin, GD .
CLINICAL RADIOLOGY, 1999, 54 (05) :294-300
[8]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[9]   Sequential helical CT angiography of aortoiliac disease [J].
Raptopoulos, V ;
Rosen, MP ;
Kent, KC ;
Kuestner, LM ;
Sheiman, RG ;
Pearlman, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1347-1354
[10]  
Rubin GD, 1999, J COMPUT ASSIST TOMO, V23, pS83