Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography

被引:165
|
作者
Rubin, GD [1 ]
Shiau, MC [1 ]
Leung, AN [1 ]
Kee, ST [1 ]
Logan, LJ [1 ]
Sofilos, MC [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
aneurysm; aorta; CT; dissection; computed tomography (CT); angiography; comparative studies; helical; technology;
D O I
10.1148/radiology.215.3.r00jn18670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography. MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material). RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds). CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 50 条
  • [1] Stair-step artifacts with single versus multiple detector-row helical CT
    Fleischmann, D
    Rubin, GD
    Paik, DS
    Yen, SY
    Hilfiker, PR
    Beaulieu, CF
    Napel, S
    RADIOLOGY, 2000, 216 (01) : 185 - 196
  • [2] How to design injection protocols for multiple detector-row CT angiography (MDCTA)
    Fleischmann, D
    EUROPEAN RADIOLOGY, 2005, 15 : E60 - E65
  • [3] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [4] Computed tomographic angiography: Historical perspective and new state-of-the-art using multi detector-row helical computed tomography
    Rubin, GD
    Shiau, MC
    Schmidt, AJ
    Fleischmann, D
    Logan, L
    Leung, AN
    Jeffrey, RB
    Napel, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 : S83 - S90
  • [5] Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: Comparison with conventional angiography
    Remy-Jardin, M
    Bouaziz, N
    Dumont, P
    Brillet, PY
    Bruzzi, J
    Remy, J
    RADIOLOGY, 2004, 233 (03) : 741 - 749
  • [6] CT colonography: Single-versus multi-detector row imaging
    Hara, AK
    Johnson, CD
    MacCarty, RL
    Welch, TJ
    McCollough, CH
    Harmen, WS
    RADIOLOGY, 2001, 219 (02) : 461 - 465
  • [7] Single- versus multi-detector row CT of the brain: Quality assessment
    Jones, TR
    Kaplan, RT
    Lane, B
    Atlas, SW
    Rubin, GD
    RADIOLOGY, 2001, 219 (03) : 750 - 755
  • [8] Multi-detector row helical CT angiography of hepatic vessels: Depiction with dual-arterial phase acquisition during single breath hold
    Takahashi, S
    Murakami, T
    Takamura, M
    Kim, T
    Hori, M
    Narumi, Y
    Nakamura, H
    Kudo, M
    RADIOLOGY, 2002, 222 (01) : 81 - 88
  • [9] Hepatic arteries in potential donors for living related liver transplantation: Evaluation with multi-detector row CT angiography
    Lee, SS
    Kim, TK
    Byun, JH
    Ha, HK
    Kim, PN
    Kim, AY
    Lee, SG
    Lee, MG
    RADIOLOGY, 2003, 227 (02) : 391 - 399
  • [10] Coronary artery bypass graft flow: Qualitative evaluation with cine single-detector row CT and comparison with findings at angiography
    Tello, R
    Hartnell, GG
    Costello, P
    Ecker, CP
    RADIOLOGY, 2002, 224 (03) : 913 - 918