Improving subspace constrained radial fast spin echo MRI using block matching driven non-local low rank regularization

被引:4
作者
Mandava, Sagar [1 ,2 ]
Keerthivasan, Mahesh B. [1 ,2 ]
Martin, Diego R. [2 ]
Altbach, Maria, I [2 ,3 ]
Bilgin, Ali [1 ,2 ,3 ]
机构
[1] Univ Arizona, Dept Elect & Comp Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Med Imaging, Tucson, AZ 85721 USA
[3] Univ Arizona, Dept Biomed Engn, Tucson, AZ USA
关键词
parameter mapping; subspace-constraint; block matching; non-local low rank; image reconstruction; accelerated imaging; multi-contrast MRI; MODEL-BASED RECONSTRUCTION; IMAGE-RECONSTRUCTION; UNDERSAMPLED DATA; SPARSITY; CARTILAGE; RELAXATION; SENSE;
D O I
10.1088/1361-6560/abd4b8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Subspace-constrained reconstruction methods restrict the relaxation signals (of size M) in the scene to a pre-determined subspace (of size KMUCH LESS-THANM) and allow multi-contrast imaging and parameter mapping from accelerated acquisitions. However, these constraints yield poor image quality at some imaging contrasts, which can impact the parameter mapping performance. Additional regularization such as the use of joint-sparse (JS) or locally-low-rank (LLR) constraints can help improve the recovery of these images but are not sufficient when operating at high acceleration rates. We propose a method, non-local rank 3D (NLR3D), that is built on block matching and transform domain low rank constraints to allow high quality recovery of subspace-coefficient images (SCI) and subsequent multi-contrast imaging and parameter mapping. The performance of NLR3D was evaluated using Monte-Carlo (MC) simulations and compared against the JS and LLR methods. In vivo T-2 mapping results are presented on brain and knee datasets. MC results demonstrate improved bias, variance, and MSE behavior in both the multi-contrast images and parameter maps when compared to the JS and LLR methods. In vivo brain and knee results at moderate and high acceleration rates demonstrate improved recovery of high SNR early TE images as well as parameter maps. No significant difference was found in the T2 values measured in ROIs between the NLR3D reconstructions and the reference images (Wilcoxon signed rank test). The proposed method, NLR3D, enables recovery of high-quality SCI and, consequently, the associated multi-contrast images and parameter maps.
引用
收藏
页数:12
相关论文
共 50 条
[1]   Low-dimensional-Structure Self-Learning and Thresholding: Regularization Beyond Compressed Sensing for MRI Reconstruction [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Goddu, Beth ;
Goepfert, Lois A. ;
Kissinger, Kraig V. ;
Tarokh, Vahid ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) :756-767
[2]   PatchMatch: A Randomized Correspondence Algorithm for Structural Image Editing [J].
Barnes, Connelly ;
Shechtman, Eli ;
Finkelstein, Adam ;
Goldman, Dan B. .
ACM TRANSACTIONS ON GRAPHICS, 2009, 28 (03)
[3]   Accelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction [J].
Ben-Eliezer, Noam ;
Sodickson, Daniel K. ;
Shepherd, Timothy ;
Wiggins, Graham C. ;
Block, Kai Tobias .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) :1346-1354
[4]   Accelerated whole-brain multi-parameter mapping using blind compressed sensing [J].
Bhave, Sampada ;
Lingala, Sajan Goud ;
Johnson, Casey P. ;
Magnotta, Vincent A. ;
Jacob, Mathews .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) :1175-1186
[5]   Multi-contrast Reconstruction With Bayesian Compressed Sensing [J].
Bilgic, Berkin ;
Goyal, Vivek K. ;
Adalsteinsson, Elfar .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) :1601-1615
[6]   Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1759-1769
[7]   Distributed optimization and statistical learning via the alternating direction method of multipliers [J].
Boyd S. ;
Parikh N. ;
Chu E. ;
Peleato B. ;
Eckstein J. .
Foundations and Trends in Machine Learning, 2010, 3 (01) :1-122
[8]   High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI [J].
Bustin, Aurelien ;
da Cruz, Gastao Lima ;
Jaubert, Olivier ;
Lopez, Karina ;
Botnar, Rene M. ;
Prieto, Claudia .
MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) :3705-3719
[9]   Five-minute whole-heart coronary MRA with sub-millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D-PROST reconstruction [J].
Bustin, Aurelien ;
Ginami, Giulia ;
Cruz, Gastao ;
Correia, Teresa ;
Ismail, Tevfik F. ;
Rashid, Imran ;
Neji, Radhouene ;
Botnar, Rene M. ;
Prieto, Claudia .
MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) :102-115
[10]   Discrimination of benign from malignant hepatic lesions based on their T2-relaxation times calculated from moderately T2-weighted turbo SE sequence [J].
Cieszanowski, A ;
Szeszkowski, W ;
Golebiowski, M ;
Bielecki, DK ;
Grodzicki, M ;
Pruszynski, B .
EUROPEAN RADIOLOGY, 2002, 12 (09) :2273-2279