Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus A systematic review of benefits and harms

被引:20
|
作者
Brorson, Stig [1 ]
Frich, Lars H. [2 ]
Winther, Annika [1 ]
Hrobjartsson, Asbjorn [3 ]
机构
[1] Herlev Univ Hosp, Dept Orthopaed Surg, DK-2730 Herlev, Denmark
[2] Odense Univ Hosp, Dept Orthopaed Surg, DK-5000 Odense, Denmark
[3] Rigshosp, Nord Cochrane Ctr, DK-2100 Copenhagen, Denmark
关键词
ANGULAR-STABLE PLATE; FIXED-ANGLE PLATE; INTERNAL-FIXATION; PHILOS-PLATE; COMPRESSION PLATE; ELDERLY-PATIENTS; OPEN REDUCTION; PRIMARY HEMIARTHROPLASTY; NONOPERATIVE TREATMENT; COMMINUTED FRACTURES;
D O I
10.3109/17453674.2011.588856
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries. Methods We systematically identified and reviewed clinical studies on the benefits and harms after osteosynthesis with locking plates in displaced 4-part fractures. Results We included 14 studies with 374 four-part fractures. There were 10 case series, 3 retrospective observational comparative studies, 1 prospective observational comparative study, and no randomized trials. Small studies with a high risk of bias precluded reliable estimates of functional outcome. High rates of complications (16-64%) and reoperations (11-27%) were reported. Interpretation The empirical foundation for the value of locking plates in displaced 4-part fractures of the proximal humerus is weak. We emphasize the need for well-conducted randomized trials and observational studies.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [41] Operative treatment of 2-part surgical neck type fractures of the proximal humerus in the elderly: Cement augmented locking plate PHILOS™ vs. proximal humerus nail multiloc®
    Helfen, Tobias
    Siebenbuerger, Georg
    Fleischhacker, Evi
    Gleich, Johannes
    Boecker, Wolfgang
    Ockert, Ben
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (10): : 2245 - 2252
  • [42] Clinical Longer-Term Results After Internal Fixation of Proximal Humerus Fractures With a Locking Compression Plate (PHILOS)
    Hirschmann, Michael Tobias
    Fallegger, Basil
    Amsler, Felix
    Regazzoni, Pietro
    Gross, Thomas
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (05) : 286 - 293
  • [43] Hemiarthroplasty versus nonoperative treatment of displaced 4-part proximal humeral fractures in elderly patients: a randomized controlled trial
    Olerud, Per
    Ahrengart, Leif
    Ponzer, Sari
    Saving, Jenny
    Tidermark, Jan
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (07) : 1025 - 1033
  • [44] Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies
    Biermann, Niklas
    Prall, Wolf Christian
    Boecker, Wolfgang
    Mayr, Hermann Otto
    Haasters, Florian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (08) : 1075 - 1099
  • [45] Locking plates versus intramedullary nails in the management of displaced proximal humeral fractures: a systematic review and meta-analysis
    Sun, Qi
    Ge, Wei
    Li, Gen
    Wu, Jiezhou
    Lu, Guanghua
    Cai, Ming
    Li, Shaohua
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (03) : 641 - 650
  • [46] Efficacy of fracture stem in reverse shoulder arthroplasty for 3-or 4-part proximal humerus fractures
    Sasanuma, Hideyuki
    Iijima, Yuki
    Saito, Tomohiro
    Saitsu, Akihiro
    Saito, Toshihiro
    Matsumura, Tomohiro
    Takeshita, Katsushi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1266 - 1273
  • [47] Intramedullary nailing of displaced four-part fractures of the proximal humerus
    Kloub, Martin
    Holub, Karel
    Urban, Jiri
    Latal, Pavel
    Peml, Marek
    Krivohlavek, Martin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 1978 - 1985
  • [48] Locking plate fixation for proximal humerus fractures-when do I use a fibular strut?
    Stone, Geoffrey P.
    Christmas, Kaitlyn N.
    Mighell, Mark A.
    ANNALS OF JOINT, 2020, 5
  • [49] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review
    Jabran, Ali
    Peach, Chris
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [50] Internal Fixation Versus Shoulder Hemiarthroplasty for Displaced 4-part Proximal Humeral Fractures in Elderly Patients
    Cai, Ming
    Tao, Kun
    Yang, Chunxi
    Li, Shaohua
    ORTHOPEDICS, 2012, 35 (09) : E1340 - E1346