Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus A systematic review of benefits and harms

被引:20
|
作者
Brorson, Stig [1 ]
Frich, Lars H. [2 ]
Winther, Annika [1 ]
Hrobjartsson, Asbjorn [3 ]
机构
[1] Herlev Univ Hosp, Dept Orthopaed Surg, DK-2730 Herlev, Denmark
[2] Odense Univ Hosp, Dept Orthopaed Surg, DK-5000 Odense, Denmark
[3] Rigshosp, Nord Cochrane Ctr, DK-2100 Copenhagen, Denmark
关键词
ANGULAR-STABLE PLATE; FIXED-ANGLE PLATE; INTERNAL-FIXATION; PHILOS-PLATE; COMPRESSION PLATE; ELDERLY-PATIENTS; OPEN REDUCTION; PRIMARY HEMIARTHROPLASTY; NONOPERATIVE TREATMENT; COMMINUTED FRACTURES;
D O I
10.3109/17453674.2011.588856
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries. Methods We systematically identified and reviewed clinical studies on the benefits and harms after osteosynthesis with locking plates in displaced 4-part fractures. Results We included 14 studies with 374 four-part fractures. There were 10 case series, 3 retrospective observational comparative studies, 1 prospective observational comparative study, and no randomized trials. Small studies with a high risk of bias precluded reliable estimates of functional outcome. High rates of complications (16-64%) and reoperations (11-27%) were reported. Interpretation The empirical foundation for the value of locking plates in displaced 4-part fractures of the proximal humerus is weak. We emphasize the need for well-conducted randomized trials and observational studies.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [1] Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review
    Brorson, Stig
    Rasmussen, Jeppe Vejlgaard
    Frich, Lars Henrik
    Olsen, Bo Sanderhoff
    Hrobjartsson, Asbjorn
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 999 - 1005
  • [2] Outcomes of plate osteosynthesis for displaced 3-part and 4-part proximal humerus fractures with deltopectoral vs. deltoid split approach
    Bhayana, Himanshu
    Chouhan, Devendra Kumar
    Aggarwal, Sameer
    Prakash, Mahesh
    Patel, Sandeep
    Arora, Chirag
    Dhillon, Mandeep Singh
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4559 - 4567
  • [3] A systematic review of locking plate fixation of proximal humerus fractures
    Sproul, Robert C.
    Iyengar, Jaicharan J.
    Devcic, Zlatko
    Feeley, Brian T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (04): : 408 - 413
  • [4] Conservative treatment of 3-part and 4-part proximal humeral fractures: a systematic review
    Soler-Peiro, Manuel
    Garcia-Martinez, Lorena
    Aguilella, Luis
    Perez-Bermejo, Marcelino
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [5] Comparison of Surgical versus Non-Surgical Treatment of Displaced 3-and 4-Part Fractures of the Proximal Humerus: A Meta-Analysis
    Mao, Feng
    Zhang, De-Hua
    Peng, Xiao-Chun
    Liao, Yi
    JOURNAL OF INVESTIGATIVE SURGERY, 2015, 28 (04) : 215 - 224
  • [6] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Kavuri, Venkat
    Bowden, Blake
    Kumar, Neil
    Cerynik, Doug
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 108 - 116
  • [7] Dual Locking Plate Osteosynthesis for 3-or 4-Part Proximal Humeral Fractures Combined with Multiple Fractures of the Greater Tuberosity
    Li, Yongchuan
    Lu, Nan
    Zhang, Fan
    Zhou, Zhibin
    Zhao, Liangyu
    Chen, Aimin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (03) : 695 - 701
  • [8] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [9] Dual Locking Plate Osteosynthesis for 3- or 4-Part Proximal Humeral Fractures Combined with Multiple Fractures of the Greater Tuberosity
    Yongchuan Li
    Nan Lu
    Fan Zhang
    Zhibin Zhou
    Liangyu Zhao
    Aimin Chen
    Indian Journal of Orthopaedics, 2021, 55 : 695 - 701
  • [10] Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?
    Koenigshausen, M.
    Kuebler, L.
    Godry, H.
    Citak, M.
    Schildhauer, T. A.
    Seybold, D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 223 - 231