Corrosion and premature capacity loss of standby telecommunications batteries - The way forward for service providers

被引:0
作者
Ng'weno, HM
机构
来源
INTELEC'03: POWERING THE BROADBAND NETWORK, PROCEEDINGS | 2003年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There are two failure mechanism associated with batteries on float charge in telecommunications installations. The first is corrosion of the positive plate and the second is capacity loss. Periodic maintenance, monitoring and proper battery selection during procurement will prevent any loss of lifetime or performance from grid corrosion and capacity loss. The paper will examine the causes of these two battery failure modes in telecommunication installations and outline various recommendations to be adapted during procurement and maintenance to ensure that the battery installation is efficient, reliable and long lasting.
引用
收藏
页码:444 / 450