Axial view inductively coupled plasma optical emission spectrometry for monitoring tin concentration in canned tomato sauce samples

被引:17
作者
da Boa Morte, Elane Santos [1 ,2 ]
Barbosa, Isa dos Santos [1 ]
Santos, Elisangela Costa [1 ]
Nobrega, Joaquim Araujo [3 ]
Andrade Korn, Maria das Gracas [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170115 Salvador, BA, Brazil
[2] Inst Fed Educ Ciencia & Tecnol Baiano, Catu, BA, Brazil
[3] Univ Fed Sao Carlos, Dept Quim, Sao Paulo, Brazil
关键词
Tin; Canned food samples; Axial view ICP OES; ATOMIC-ABSORPTION-SPECTROMETRY; SPECTROPHOTOMETRIC DETERMINATION; FLUOROMETRIC-DETERMINATION; SN; SPECIATION; JUICES; SN(IV); COPPER; FOODS; PB;
D O I
10.1016/j.foodchem.2011.08.015
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In this study it was evaluated the variation of tin concentration in function of storage time in canned food samples by using an axial view inductively coupled plasma optical emission spectrometry (AX ICP OES). The effect of various parameters of the ICP OES, such as analytical lines, sample introduction systems and interferences were investigated. Eight emission lines for tin were tested, but only 283.998 nm line was found to be robust enough with respect to interferences and sensitivity, presenting a limit of quantification of 0.094 mg kg(-1). A concentric nebuliser combined with a cyclonic chamber has shown better sensitivity than a V-groove nebuliser. Tin was determined in canned tomato sauce stored at room temperature (20.0 +/- 1.8 degrees C) for 0, 30, 60, 90, 120 and 150 days. After 150 days, tin contents increased in the 43-91% range. Despite an increase of almost 100% for one sample, tin contents are well below the maximum level allowed by Agencia Nacional de Vigilancia Sanitaria (ANVISA) regulation of 250 mg kg(-1). (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 352
页数:5
相关论文
共 28 条
  • [1] Lobo FA, 2007, ATOM SPECTROSC, V28, P17
  • [2] RAPID AND SELECTIVE METHOD FOR THE SPECTROPHOTOMETRIC DETERMINATION OF TIN USING POTASSIUM ETHYLXANTHATE
    ARYA, SP
    BANSAL, A
    [J]. MIKROCHIMICA ACTA, 1994, 116 (1-3) : 63 - 71
  • [3] DIRECT DETERMINATION OF TIN IN TAP WATERS BY ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROSCOPY
    BERMEJOBARRERA, P
    SOTOFERREIRO, RM
    BERMEJOBARRERA, A
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (01): : 60 - 62
  • [4] Tin in canned food: a review and understanding of occurrence and effect
    Blunden, S
    Wallace, T
    [J]. FOOD AND CHEMICAL TOXICOLOGY, 2003, 41 (12) : 1651 - 1662
  • [5] Sequential injection fluorimetric determination of Sn in juices of canned fruits
    Boa Morte, Elane S.
    Korn, Maria Gracas A.
    Saraiva, M. Lucia M. F. S.
    Lima, Jose L. F. C.
    Pinto, Paula C. A. G.
    [J]. TALANTA, 2009, 79 (04) : 1100 - 1103
  • [6] Speciation analysis of Sn(II) and Sn(IV) using baker's yeast and inductively coupled plasma optical emission spectrometry
    Caldorin, Rogerio
    Menegario, Amauri A.
    [J]. MICROCHIMICA ACTA, 2007, 157 (3-4) : 201 - 207
  • [7] FLOW-INJECTION METHOD FOR THE DETERMINATION OF TIN IN FRUIT JUICES USING SOLID-PHASE SPECTROPHOTOMETRY
    CAPITANVALLVEY, LF
    VALENCIA, MC
    MIRON, G
    [J]. ANALYTICA CHIMICA ACTA, 1994, 289 (03) : 365 - 370
  • [8] Simultaneous determination of lead, nickel, tin and copper in aluminium-base alloys using slurry sampling by electrical discharge and multielement ETAAS
    Carrión, N
    Itriago, AM
    Alvarez, MA
    Eljuri, E
    [J]. TALANTA, 2003, 61 (05) : 621 - 632
  • [9] Chan KC, 2006, J AOAC INT, V89, P469
  • [10] Spectrophotometric determination of tin in copper-based alloys using Pyrocatechol Violet
    Costa, ACS
    Teixeira, LSG
    Ferreira, SLC
    [J]. TALANTA, 1995, 42 (12) : 1973 - 1978