Optimized seismic retrofit of steel-concrete composite buildings

被引:21
作者
Papavasileiou, Georgios S. [1 ]
Charmpis, Dimos C. [2 ]
Lagaros, Nikos D. [3 ]
机构
[1] Univ Wolverhampton, Sch Architecture & Built Environm, Wulfruna St, Wolverhampton WV1 1LY, England
[2] Univ Cyprus, Dept Civil & Environm Engn, 75 Kallipoleos Str,POB 20537, CY-1678 Nicosia, Cyprus
[3] Natl Tech Univ Athens, Sch Civil Engn, Inst Struct Anal & Antiseism Res, 9 Heroon Polytech Str,Zografou Campus, Athens 15780, Greece
关键词
Strengthening; Concrete jacket; Steel cage; Steel bracing; Cost-effectiveness; Structural optimization; RC FRAMES; JACKETED COLUMNS; STRENGTH; PERFORMANCE; BEHAVIOR; DESIGN; SYSTEMS; ANGLES; BEAMS;
D O I
10.1016/j.engstruct.2020.110573
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work is focused on comparatively assessing the cost-effectiveness of three seismic retrofit approaches for non-code-conforming frame buildings with steel-concrete composite columns. The first two of the assessed retrofit approaches aim in indirectly enhancing structural system performance by strengthening individual composite columns using reinforced concrete jackets or concrete-covered steel cages. The third retrofit approach considered aims in upgrading the composite building frame at hand by installing steel bracings at selected bays. A specially developed structural optimization procedure is used to perform an objective comparison of the cost-effectiveness of the three retrofit approaches. The objective of the optimization procedure is to minimize the total retrofit material cost, while constraints are imposed to ensure the satisfaction of design requirements for the retrofitted structure regarding member capacities (according to Eurocodes 3 and 4 for steel beams and composite columns, respectively), structural system performance under horizontal loading (based on interstorey drifts calculated by pushover analyses) and fundamental periods (obtained from eigenvalue analyses). By defining 30 cases of under-designed 2-storey, 4-storey and 6-storey composite buildings (Le. buildings with steel-concrete composite columns), an extensive numerical investigation involving 120 retrofit optimization runs was conducted. The results obtained provide insight into the relative cost-effectiveness of the three seismic retrofit approaches and reveal certain conditions under which each approach is economically most viable.
引用
收藏
页数:12
相关论文
共 48 条
[1]   Axially loaded RC columns strengthened by steel caging. Finite element modelling [J].
Adam, Jose M. ;
Ivorra, Salvador ;
Pallares, Francisco J. ;
Gimenez, Ester ;
Calderon, Pedro A. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (06) :2265-2276
[2]  
American Society of Civil Engineers, 2006, 4106 ASCE SEI
[3]  
[Anonymous], 7WCEE C P 2 SEM REP
[4]   STEEL BRACING OF RC FRAMES FOR SEISMIC RETROFITTING [J].
BADOUX, M ;
JIRSA, JO .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (01) :55-74
[5]  
BETT BJ, 1988, ACI STRUCT J, V85, P499
[6]   RC columns externally strengthened with RC jackets [J].
Campione, G. ;
Fossetti, M. ;
Giacchino, C. ;
Minafo, G. .
MATERIALS AND STRUCTURES, 2014, 47 (10) :1715-1728
[8]   Behaviour of rehabilitated RC beams with self-compacting concrete jacketing - Analytical model and test results [J].
Chalioris, Constantin E. ;
Thermou, Georgia E. ;
Pantazopoulou, Stavroula J. .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 55 :257-273
[9]   Effect of steel wrapping jackets on the bond strength of concrete and the lateral performance of circular RC columns [J].
Choi, Eunsoo ;
Chung, Young-Soo ;
Park, Kyoungsoo ;
Jeon, Jong-Su .
ENGINEERING STRUCTURES, 2013, 48 :43-54
[10]  
Comite Europeen de Normalisation, 2003, EUR 3 DES STEEL STRU