Residual intra-fraction error in robotic spinal stereotactic body radiotherapy without immobilization devices

被引:9
|
作者
Rossi, Eleonora [1 ]
Fiorino, Claudio [1 ]
Fodor, Andrei [2 ]
Deantoni, Chiara [2 ]
Mangili, Paola [1 ]
Di Muzio, Nadia Gisella [2 ]
Del Vecchio, Antonella [1 ]
Broggi, Sara [1 ]
机构
[1] Ist Sci San Raffaele, Med Phys, Milan, Italy
[2] Ist Sci San Raffaele, Radiotherapy, Milan, Italy
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2020年 / 16卷
关键词
Spine SBRT; Residual error; Cyberknife; RADIATION-THERAPY; INTRAFRACTION MOTION; PATIENT MOTION; RADIOSURGERY; METASTASES; ACCURACY; TUMORS; PAIN;
D O I
10.1016/j.phro.2020.09.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Spinal stereotactic body radiotherapy (SBRT) involves large dose gradients and high geometrical accuracy is therefore required. The aim of this work was to assess residual intra-fraction error with a tracking robotic system for non-immobilized patients. Shifts from the first alignment (i.e. mimicking the unavailability of tracking) were also quantified. Materials and methods: Forty-two patients treated for spinal metastasis (128 fractions, 4220 images) were analyzed. Residual error was quantified as the difference between translations/rotations referring to consecutive x-ray images during delivery (tracking) and to the initial set-up (no-tracking). The error distribution for each fraction/patient and the entire population was assessed for each axis/rotation angle. The impact of lesion sites, fractionation and patient's pain (VAS score) were investigated. Finally, the dosimetric impact of residual motion was quantified in the four most affected fractions. Results: Mean overall errors (OE) were near 0 (SD < 0.1 mm). Residual translations/rotations >1 mm/1. were found in less than 1.5%/1% of measurements. Lesion site and fractionation showed no impact. The dosimetric impact in the most affected fractions was negligible. For "no-tracking", mean OE was <1 mm/0.5 degrees; less than 2% of displacements were >2 mm/1 degrees within 10 min from the start of treatment with an increasing probability of shifts >2 mm over time. A significantly higher fraction of OE >= 2 mm was found for patients with pain in case of no-tracking. Conclusions: Spine tracking with a latest-generation robotic system is highly efficient for non-immobilized patients: residual error is time independent and close to 0. For delivery times >7-8 min, tracking should be considered as mandatory for non-immobilized patients.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 14 条
  • [1] A retrospective study on clinical factors influencing intra-fraction motion using volumetric imaging for spine stereotactic body radiotherapy
    Venkataraman, Sankar
    Abdalmassih, Michael
    Hanumanthappa, Nikesh
    Pareek, Vibhay
    Kulshrestha, Rashi
    Lambert, Pascal
    Rathod, Srinivas
    Butler, Jim
    Dubey, Arbind
    JOURNAL OF RADIOSURGERY AND SBRT, 2023, 8 (04): : 305 - 312
  • [2] Transperineal ultrasound is a good alternative for intra-fraction motion monitoring for prostate stereotactic body radiotherapy
    Guo, Bingqi
    Stephans, Kevin
    Godley, Andrew
    Kolar, Matt
    Magnelli, Anthony
    Tendulkar, Rahul
    Mian, Omar
    Majkszak, David
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [3] Inter- and intra-fraction motion in stereotactic body radiotherapy for spinal and paraspinal tumours using cone-beam CT and positional correction in six degrees of freedom
    Finnigan, Renee
    Lamprecht, Brock
    Barry, Tamara
    Jones, Kimberley
    Boyd, Joshua
    Pullar, Andrew
    Burmeister, Bryan
    Foote, Matthew
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (01) : 112 - 118
  • [4] Cone-Beam CT assessment of inter-fraction and intra-fraction motions during lung stereotactic body radiotherapy with and without abdominal compression
    Zhang, M.
    Jiang, R.
    Zhan, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 494 - 496
  • [5] A review of surface guidance in extracranial stereotactic body radiotherapy (SBRT/SABR) for set-up and intra-fraction motion management
    Lawler, Gavin
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 21 : 23 - 26
  • [6] Evaluation of inter- and intra-fraction 6D motion for stereotactic body radiation therapy of spinal metastases: influence of treatment time
    Henni, Ahmed Hadj
    Gensanne, David
    Roge, Maximilien
    Hanzen, Chantal
    Bulot, Guillaume
    Colard, Elyse
    Thureau, Sebastien
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [7] Time Dependence of Intra-fractional Motion in Spinal Stereotactic Body Radiotherapy
    Hirai, Ryuta
    Ohkubo, Yu
    Igari, Mitsunobu
    Kumazaki, Yu
    Aoshika, Tomomi
    Ryuno, Yasuhiro
    Saito, Satoshi
    Abe, Takanori
    Noda, Shin-Ei
    Kato, Shingo
    IN VIVO, 2021, 35 (04): : 2433 - 2437
  • [8] Impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy
    Cuccia, Francesco
    Mazzola, Rosario
    Nicosia, Luca
    Figlia, Vanessa
    Giaj-Levra, Niccolo
    Ricchetti, Francesco
    Rigo, Michele
    Vitale, Claudio
    Mantoan, Beatrice
    De Simone, Antonio
    Sicignano, Gianluisa
    Ruggieri, Ruggero
    Cavalleri, Stefano
    Alongi, Filippo
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [9] Does radiotherapy planning without breath control compensate intra-fraction heart and its compartments' movement?
    Tezcanli, Evrim Kadriye
    Goksel, Evren Ozan
    Yildiz, Erdem
    Garipagaoglu, Melahat
    Senkesen, Oznur
    Kucucuk, Halil
    Sengoz, Kazim Meric
    Aslay, Isik
    BREAST CANCER RESEARCH AND TREATMENT, 2011, 126 (01) : 85 - 92
  • [10] Hypofractionated Stereotactic Body Radiotherapy in Spinal Metastasis - With or Without Epidural Extension
    Anand, A. K.
    Venkadamanickam, G.
    Punnakal, A. U.
    Walia, B. S.
    Kumar, A.
    Bansal, A. K.
    Singh, H. M.
    CLINICAL ONCOLOGY, 2015, 27 (06) : 345 - 352