A cheap amperometric and optical sensor for glucose, based oil an ITO electrode coated with electrodeposited Co/Al hydrotalcite (HT) is described. Cobalt based HT shows a reversible electrochromic behavior which can be exploited for the development of an optical sensor. Working in the optical mode, the linearity range of the sensor is between 0.008 and 0.13 mM with a sensitivity of 1.14 mM(-1) . cm(-2), whereas when working in the amperometric mode, the linearity ranges from 0.002 to 1.5 mM with a sensitivity of 4.24 x 10(-4) A . mM(-1) . cm(-2). The sensor has been successfully employed for the determination of glucose in a serum sample.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 16 条
[1]   Electrooxidation of aliphatic and aromatic amines at a Ni,Al based hydrotalcite modified electrode [J].
Carpani, Irene ;
Tonelli, Domenica .
ELECTROANALYSIS, 2006, 18 (24) :2421-2425
[2]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326
[3]   Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes [J].
Florescu, M ;
Brett, CMA .
TALANTA, 2005, 65 (02) :306-312
[4]   Transition metal half-sandwich complexes as redox mediators to glucose oxidase [J].
Forrow, NJ ;
Walters, SJ .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (07) :763-770
[5]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[6]   Fundamental studies of glucose oxidase deposition on a Pt electrode [J].
Matsumoto, N ;
Chen, XH ;
Wilson, GS .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :362-367
[7]   Effect of the presence of [Co(bpy)3]2+ on the electrochromic responses of films of a redox active Ni-Al-layered double hydroxide [J].
Mondal, Debajyoti ;
Villemure, Gilles .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 628 (1-2) :67-72
[8]   Sensors and biosensors based on clay-modified electrodes - new trends [J].
Mousty, C .
APPLIED CLAY SCIENCE, 2004, 27 (3-4) :159-177
[9]   Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability [J].
Ricci, F ;
Amine, A ;
Palleschi, G ;
Moscone, D .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :165-174
[10]   Electrochemical sensors based on electrodes modified with synthetic hydrotalcites [J].
Scavetta, E ;
Ballarin, B ;
Berrettoni, M ;
Carpani, I ;
Giorgetti, M ;
Tonelli, D .
ELECTROCHIMICA ACTA, 2006, 51 (11) :2129-2134