Efficiency of fleece-bound seating (TachoSil®) of air leaks in lung surgery:: a prospective randornised trial

被引:118
作者
Anegg, Udo [1 ]
Matzi, Veronika
Smolle, Josef
Maier, Alfred
Smolle-Juettner, Freyja
机构
[1] Graz Univ, Sch Med, Div Thorac & Hyperbar Surg, Graz, Austria
[2] Graz Univ, Sch Med, Inst Med Informat Stat & Documentat, Graz, Austria
关键词
air leakage; lung tissue seating; TachoSil (R);
D O I
10.1016/j.ejcts.2006.11.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Persistent air leakage following pulmonary resection is a major limiting factor for discharge from hospital. The aim of this study was to evaluate the seating capacity of TachoSil((R)) for the closure of alveolar air leaks following parenchymal resections and to determine its effect on time to chest drain removal and duration of hospitalisation. Methods: A total of 173 patients undergoing lobectomy or segmentectomy were enrolled in a single-centre, randomised study to compare the efficacy of TachoSil((R)) with standard treatment. Alveolar air leaks were evaluated intraoperatively by submersion of the resection site in saline And were graded according to the Macchiarini scale as 0 (no bubbles), 1 (single bubbles), 2 (stream of bubbles), 3 (coalescent bubbles). Patients with grade 1 or 2 air leaks were randomised to TachoSil((R)) or standard treatment. Grade 3 patients received standard treatment until the air leak was downgraded to grade 1 or 2 at which point they were randomised. Patients with grade 0 leakage were excluded. The primary efficacy endpoints of the study were postoperative quantification of air leakage on postoperative days 1 and 2. Other efficacy measurements included mean time to chest drain removal and mean time to hospital discharge. Results: The mean intraoperative post-treatment air leakage was significantly tower in the TachoSil(8) group (153.32 ml/min, range: 10-450 ml/min) compared with the standard treatment group (251.04 mt/min, range: 15-970 ml/min; P = 0.009). The significant difference in air leakage volume observed intraoperatively post-treatment was maintained postoperatively. TachoSil((R)) showed a trend towards reduced incidence of postoperative leakage when measured > 48 h or > 7 days after surgery (30.7% vs 38.96% and 24% vs 32.46%, respectively). The mean times to chest drain removal and to hospital discharge were significantly reduced following the use of TachoSil((R)) (5.1 days vs 6.3 days, P = 0.022 and 6.2 days vs 7.7 days, P = 0.01, respectively). Conclusions: The use of TachoSil((R)) following pulmonary resection resulted in a reduction in air leakage compared with standard techniques. This reduction in air leakage resulted in a significant reduction in both the time to chest drain removal and the period of hospitalisation. (c) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 202
页数:5
相关论文
共 17 条
  • [1] Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection
    Allen, MS
    Wood, DE
    Hawkinson, RW
    Harpole, DH
    McKenna, RJ
    Walsh, GL
    Vallieres, E
    Miller, DL
    Nichols, FC
    Smythe, WR
    Davis, RD
    [J]. ANNALS OF THORACIC SURGERY, 2004, 77 (05) : 1792 - 1801
  • [2] AIRFIX®:: the first digital postoperative chest tube airflowmetry -: a novel method to quantify air leakage after lung resection
    Anegg, Udo
    Lindenmann, Jorg
    Matzi, Veronika
    Mujkic, Dzenana
    Maier, Alfred
    Fritz, Lukas
    Smolle-Juettner, Freyja Maria
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (06) : 867 - 872
  • [3] CARBON TR, 2002, SCI CLIN APPL
  • [4] Predictors and treatment of persistent air leaks
    Cerfolio, RJ
    Bass, CS
    Pask, AH
    Katholi, CR
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (06) : 1727 - 1730
  • [5] Fibrin glue in pulmonary resection: A prospective, randomized, blinded study
    Fabian, T
    Federico, JA
    Ponn, RB
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (05) : 1587 - 1592
  • [6] EFFECT OF ROUTINE FIBRIN GLUE USE ON THE DURATION OF AIR LEAKS AFTER LOBECTOMY
    FLEISHER, AG
    EVANS, KG
    NELEMS, B
    FINLEY, RJ
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (01) : 133 - 134
  • [7] Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection:: a randomised prospective trial
    Frilling, A
    Stavrou, GA
    Mischinger, HJ
    de Hemptinne, B
    Rokkjaer, M
    Klempnauer, J
    Thörne, A
    Gloor, B
    Beckebaum, S
    Ghaffar, MFA
    Broelsch, CE
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2005, 390 (02) : 114 - 120
  • [8] Irshad K, 2002, CAN J SURG, V45, P264
  • [9] Surgical aspects and techniques of lung volume reduction surgery for severe emphysema
    Klepetko, W
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1999, 13 (04) : 919 - 925
  • [10] Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy
    Lang, G
    Csekeö, A
    Stamatis, G
    Lampl, L
    Hagman, L
    Marta, GM
    Mueller, MR
    Klepetko, W
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (02) : 160 - 166