A randomised prospective comparison of Rotecno versus new Gore occlusive surgical gowns using bacterial air counts in ultraclean air

被引:12
作者
Gulihar, A. [1 ]
Taub, N. A. [1 ]
Taylor, G. J. S. [1 ]
机构
[1] Glenfield Gen Hosp, Leicester LE3 9QP, Leics, England
关键词
Bacterial air counts; EN13795; Gore; Rotecno; Surgical gowns; OPERATING-ROOMS; TOTAL HIP; REPLACEMENT; CONTAMINATION; JOINT; SEPSIS;
D O I
10.1016/j.jhin.2009.06.010
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Ultraclean air (UCA) in operating theatres is defined as <10 colony-forming units (cfu)/m(3). The current European standards for surgical gowns are contained in EN13795 but these do not include containment of bacterial dispersal as a standard test. A trial in 2003 found that there were bacterial air counts of 1 cfu/m(3) with Rotecno owns and 0.5 cfu/m(3) with body exhaust suits in total knee arthroplasty (TKA). This study compared bacterial air counts using Rotecno gowns with a new type of occlusive gown made from Gore liquid-proof fabric, which were superior to the Rotecno gowns on standard EN 13795 laboratory testing. Fifty-six joint replacements were allocated randomly either to Rotecno or to Gore gowns with stratification into TKA, total hip arthroplasty (THA) or revision THA. Airborne bacteria were collected from within 30 cm of the wound for the first 10 min of surgery using a Casella slit sampler. The new gowns were associated with higher air counts (3.7 cfu/m(3)) than the Rotecno gowns (1.2 cfu/m(3)) (P < 0.001). Three of the Gore samples exceeded the clean air standard of 10 cfu/m(3). In TKA patients, the existing Rotecno gowns, now many years old, had higher air counts (2.0 cfu/m(3)) than in the 2003 trial (0.8 cfu/m(3)) (P < 0.001). The new gowns were superior in standard laboratory tests but not superior at preventing airborne bacterial dispersal. Rotecno gowns, although many years old, were still effective. This study highlights the importance of testing new materials in a clinical environment with UCA; in-vitro testing alone is probably not an adequate assessment. (C) 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 57
页数:4
相关论文
共 11 条
[1]   A slit samiler for collecting and counting air-borne bacteria [J].
Bourdillon, RB ;
Lidwell, OM ;
Thomas, JC .
JOURNAL OF HYGIENE, 1941, 41 (02) :197-224
[2]  
*BRIT STAND I, 2006, EN137953 BS
[3]   Air contamination during skin preparation and draping in joint replacement surgery [J].
Brown, AR ;
Taylor, GJS ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :92-94
[4]  
Charnley J, 1972, Clin Orthop Relat Res, V87, P167, DOI 10.1097/00003086-197209000-00020
[5]   Body-exhaust suit versus occlusive clothing -: A randomised, prospective trial using air and wound bacterial counts [J].
Der Tavitian, J ;
Ong, SM ;
Taub, NA ;
Taylor, GJS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (04) :490-494
[6]   AIR INFECTION WITH DUST LIBERATED FROM CLOTHING [J].
DUGUID, JP ;
WALLACE, AT .
LANCET, 1948, 252 (NOV27) :845-849
[7]   AIRBORNE CONTAMINATION OF WOUNDS IN JOINT REPLACEMENT OPERATIONS - THE RELATIONSHIP TO SEPSIS RATES [J].
LIDWELL, OM ;
LOWBURY, EJL ;
WHYTE, W ;
BLOWERS, R ;
STANLEY, SJ ;
LOWE, D .
JOURNAL OF HOSPITAL INFECTION, 1983, 4 (02) :111-131
[8]   EFFECT OF ULTRACLEAN AIR IN OPERATING-ROOMS ON DEEP SEPSIS IN THE JOINT AFTER TOTAL HIP OR KNEE REPLACEMENT - A RANDOMIZED STUDY [J].
LIDWELL, OM ;
LOWBURY, EJL ;
WHYTE, W ;
BLOWERS, R ;
STANLEY, SJ ;
LOWE, D .
BRITISH MEDICAL JOURNAL, 1982, 285 (6334) :10-14
[9]   AIDS AND THE ORTHOPEDIC SURGEON [J].
NEWTON, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :707-708
[10]   SUGGESTED BACTERIOLOGICAL STANDARDS FOR AIR IN ULTRACLEAN OPERATING-ROOMS [J].
WHYTE, W ;
LIDWELL, OM ;
LOWBURY, EJL ;
BLOWERS, R .
JOURNAL OF HOSPITAL INFECTION, 1983, 4 (02) :133-139