Automated multi-parameter high-dose-rate brachytherapy quality assurance via radioluminescence imaging

被引:11
作者
Jia, Mengyu [1 ]
Kim, Tae Jin [2 ]
Yang, Yong [1 ]
Xing, Lei [1 ]
Jean, Paul De [2 ]
Grafil, Elliot [2 ]
Jenkins, Cesare H. [2 ]
Fahimian, Benjamin P. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Luca Med Syst, Palo Alto, CA 94303 USA
关键词
radioluminescence imaging; quality assurance (QA); high dose rate (HDR) brachytherapy; VERIFICATION; IMPLEMENTATION; ARRAY; AAPM;
D O I
10.1088/1361-6560/abb570
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to leverage radioluminescence imaging for the development of an automated high-dose-rate (HDR) brachytherapy quality assurance (QA) system that enables simultaneous measurements of dwell position, dwell time, wire velocity, and relative source strength in a single test. The system consists of a radioluminescence phosphor sheet (a mixture of Gd2O2S:Tb and PDMS) positioned atop a HDR needle applicator, a complementary metal-oxide-semiconductor digital camera used to capture the emitted radioluminescence signals from the scintillator sheet, and an in-house graphical user interface for signal processing. The signal processing was used to extract source intensity, location, and elapsed time, yielding the final measurements on dwell position, dwell time, and wire velocity. The source strength relative to the well chamber calibration (in unit of Air-Kerma strength, S-k) is measured by establishing a calibration curve that correlates S-k with the detector response. Validation experiments are performed using three customized treatment plans. With these plans, the dwell position and dwell time are verified for a range of 110.0 cm-117.5 cm and 2 s-16 s, respectively, and the linear correlation with S-k is demonstrated for the source strength varying between 28 348 U (cGy cm(2) h(-1)) and 41 906 U. The wire velocity, i.e. the speed of the radioactive source averaged over the distance in between dwell positions, is calculated for various distances ranging from 5 mm to 50 mm. Results show that the mean deviations of the measured dwell position and dwell time are 0.1 mm (range from 0 to 0.2 mm) and 32.5 ms (range from 0 to 60.0 ms) with respect to the planned values, respectively, and the system response is highly linear with S-k( R-2 = 0.998). Moreover, the measured wire velocities are comparable to previously reported values. Benefitting from the compact hardware design and image processing algorithms, the system provides a practical, reliable, and comprehensive solution for HDR QA.
引用
收藏
页数:10
相关论文
共 21 条
  • [1] Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy
    Andersen, Claus E.
    Nielsen, Soren Kynde
    Lindegaard, Jacob Christian
    Tanderup, Kari
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5033 - 5043
  • [2] Beeksma B, 2014, THESIS
  • [3] Mechanical evaluation of the Bravos afterloader system for HDR brachytherapy
    Bellezzo, Murillo
    Baeza, Jose A.
    Voncken, Robert
    Reniers, Brigitte
    Verhaegen, Frank
    Fonseca, Gabriel P.
    [J]. BRACHYTHERAPY, 2019, 18 (06) : 852 - 862
  • [4] The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Bucci, J.
    Corde, S.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    [J]. MEDICAL PHYSICS, 2015, 42 (02) : 663 - 673
  • [5] High dose-rate brachytherapy source position quality assurance using radiochromic film
    Evans, M. D. C.
    Devic, S.
    Podgorsak, E. B.
    [J]. MEDICAL DOSIMETRY, 2007, 32 (01) : 13 - 15
  • [6] A novel system for commissioning brachytherapy applicators: example of a ring applicator
    Fonseca, Gabriel P.
    Van den Bosch, Michiel R.
    Voncken, Robert
    Podesta, Mark
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (21) : 8360 - 8375
  • [7] Online pretreatment verification of high-dose rate brachytherapy using an imaging panel
    Fonseca, Gabriel P.
    Podesta, Mark
    Bellezzo, Murillo
    Van den Bosch, Michiel R.
    Lutgens, Ludy
    Vanneste, Ben G. L.
    Voncken, Robert
    Van Limbergen, Evert J.
    Reniers, Brigitte
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13) : 5440 - 5461
  • [8] Relative dosimetrical verification in high dose rate brachytherapy using two-dimensional detector array IMatriXX
    Manikandan, A.
    Biplab, Sarkar
    Perianayagam, David A.
    Holla, R.
    Vivek, T. R.
    Sujatha, N.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2011, 36 (03) : 171 - 175
  • [9] Real-time verification of HDR brachytherapy source location: implementation of detector redundancy
    Nakano, T
    Suchowerska, N
    McKenzie, DR
    Bilek, MM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02) : 319 - 327
  • [10] Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56
    Nath, R
    Anderson, LL
    Meli, JA
    Olch, AJ
    Stitt, JA
    Williamson, JF
    [J]. MEDICAL PHYSICS, 1997, 24 (10) : 1557 - 1598