Thermal Comfort and its Relation to Ventilation Approaches in Non-Air-Conditioned Mosque Buildings

被引:6
作者
Rasli, Nur Baitul Izati [1 ]
Ramli, Nor Azam [1 ]
Ismail, Mohd Rodzi [2 ]
Zainordin, Nazatul Syadia [3 ]
Shith, Syabiha [1 ]
Nazir, Amni Umirah Mohamad [1 ]
机构
[1] Univ Sains Malaysia, Sch Civil Engn, Environm Assessment & Clean Air Res, George Town 14300, Malaysia
[2] Univ Sains Malaysia, Sch Housing Bldg & Planning, George Town 11800, Malaysia
[3] Univ Putra Malaysia, Dept Environm Management, Fac Environm Studies, Serdang 43400, Malaysia
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2019年 / 11卷 / 02期
关键词
Mosque; PMV; PPD; thermal comfort; ventilation; QUALITY;
D O I
10.30880/ijie.2019.11.01.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper reports the outcome of a thermal comfort study that assessed the satisfaction of occupants with their surrounding thermal conditions. The study was carried out in 10 mosque buildings around lowland Nibong Tebal, Penang and highland Cameron Highlands, Pahang. It involved determining the compliance level of thermal comfort parameters (i.e. air temperature, relative humidity and air speed) at lowland and highland and establishing relationships between ventilation systems with predicted mean vote and predicted percentage of dissatisfied at lowland and highland according to ASHRAE Standard-55. The study was conducted from 1200h to 1700h/1730h to assess the thermal conditions of the 10 mosques during Zohor/Friday and Asar prayer times. During prayer times, an active ventilation system was in operation, while before and after prayer times, only passive ventilation (windows and doors) was available. Overall, findings indicated that better thermal comfort conditions occurred during prayer time at highland compared with those at the lowland, with the thermal sensation conditions of mosques in the former 'slightly warmer' to 'slightly cool' and in the latter 'slightly warm' to 'hot'. Moreover, most mosques at lowland did not provide good thermal comfort because the percentage of dissatisfied was high compared to that at highland.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 26 条
  • [1] Abd Wahabi L, 2018, INT J INTEGR ENG, V10, P7
  • [2] Abdullah AH, 2009, INT J INTEGR ENG, V1, P27
  • [3] Defining Issue of Thermal Comfort Control through Urban Mosque Facade Design
    Abdullah, Fauziah Hanum
    Majid, Noor Hanita Abdul
    Othman, Rosniza
    [J]. AMER INTERNATIONAL CONFERENCE ON QUALITY OF LIFE: QUALITY OF LIFE IN THE BUILT & NATURAL ENVIRONMENT 4 (AICQOL2016MEDAN), 2016, 234 : 416 - 423
  • [4] Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates
    Al-Homoud, Mohammad S.
    Abdou, Adel A.
    Budaiwi, Ismail M.
    [J]. ENERGY AND BUILDINGS, 2009, 41 (06) : 607 - 614
  • [5] American Society of Heating Refrigerating and Air-Conditioning Engineers, 2007, 90 ASHRAE
  • [6] AmirHosein GhaffarianHoseini AmirHosein GhaffarianHoseini, 2012, British Journal of Environment and Climate Change, V2, P437
  • [7] [Anonymous], 2005, INT STANDARD ISO 773
  • [8] [Anonymous], 2014, P 8 WINDS C COUNT CO
  • [9] ASHRAE, 2010, 55 ASHRAE
  • [10] Guliuzza R. J, 2009, ACTS FACTS, V38, P8