摘要
Background: While the introduction of automated urine analyzers is expected to reduce the labor involved, turnaround time and potential assay variations, microscopic examination remains the "gold standard" for the analysis of urine sediments. In this study, we evaluated the analytical and diagnostic performance of five recently introduced automated urine sediment analyzers. Methods: A total of 1016 samples were examined using five automated urine sediment analyzers and manual microscopy. Concordance of results from each automated analyzer and manual microscopy were evaluated. In addition, image and microscopic review rates of each system were investigated. Results: The proportional bias for red blood cells (RBCs), white blood cells (WBCs) and squamous epithelial cells in the automated urine sediment analyzers were within +/- 20% of values obtained using the manual microscope, except in the cases of RBCs and WBCs analyzed using URiSCAN PlusScope and Iris iQ200SPRINT, respectively. The sensitivities of Roche Cobas (R) u 701 and Siemens UAS800 for pathologic casts (73.6% and 81.1%, respectively) and crystals (62.2% and 49.5%, respectively) were high, along with high image review rates (24.6% and 25.2%, respectively). The detection rates for crystals, casts and review rates can be changed for the Sysmex UF-5000 platform according to cut-off thresholds. Conclusions: Each automated urine sediment analyzer has certain distinct features, in addition to the common advantages of reducing the burden of manual processing. Therefore, laboratory physicians are encouraged to understand these features, and to utilize each system in appropriate ways, considering clinical algorithms and laboratory workflow.
引用
收藏
页码:1744 / 1753
页数:10
相关论文
共 27 条
[1]   New Generation IQ-200 Automated Urine Microscopy Analyzer Compared With KOVA Cell Chamber [J].
Altekin, Emel ;
Kadicesme, Ozgur ;
Akan, Pinar ;
Kume, Tuncay ;
Vupa, Ozgul ;
Ergor, Gul ;
Abacioglu, Hakan .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2010, 24 (02) :67-71
[2]  
[Anonymous], GP16A3 CLSI
[3]  
[Anonymous], KOVA GLASST SLID 10
[4]   Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy [J].
Bakan, Ebubekir ;
Ozturk, Nurinnisa ;
Baygutalp, Nurcan Kilic ;
Polat, Elif ;
Akpinar, Kadriye ;
Dorman, Emrullah ;
Polat, Harun ;
Bakan, Nuri .
BIOCHEMIA MEDICA, 2016, 26 (03) :365-375
[5]  
Ben-Ezra J, 1998, CLIN CHEM, V44, P92
[6]  
Budak YU, 2011, CLIN LAB, V57, P47
[7]   AUTOMATED URINALYSIS [J].
CARLSON, DA ;
STATLAND, BE .
CLINICS IN LABORATORY MEDICINE, 1988, 8 (03) :449-461
[8]   Urine sediment examination: A comparison of automated urinalysis systems and manual microscopy [J].
Chien, Tzu-I ;
Kao, Jau-Tsuen ;
Liu, Hui-Lan ;
Lin, Po-Chang ;
Hong, Jhih-Sian ;
Hsieh, Han-Peng ;
Chien, Miao-Ju .
CLINICA CHIMICA ACTA, 2007, 384 (1-2) :28-34
[9]   Comparison of three automated urinalysis systems - Bayer Clinitek Atlas, Roche Urisys 2400 and Arkray Aution Max for testing urine chemistry and detection of bacteriuria [J].
Chien, Tzu-I ;
Lu, Jin-Ying ;
Kao, Jau-Tsuen ;
Lee, Tai-Fen ;
Ho, Shu-Yuan ;
Chang, Chia-Yu ;
Liu, Chao-Wei ;
Lee, Chun-Hsien ;
Yan, Shiao-Ni ;
Yang, Jul-Yi ;
Lin, Po-Chuang ;
Wang, Mei-Ju .
CLINICA CHIMICA ACTA, 2007, 377 (1-2) :98-102
[10]   The efficient workflow to decrease the manual microscopic examination of urine sediment using on-screen review of images [J].
Cho, Eun-Jung ;
Ko, Dae-Hyun ;
Lee, Woochang ;
Chun, Sail ;
Lee, Hae Kyung ;
Min, Won-Ki .
CLINICAL BIOCHEMISTRY, 2018, 56 :70-74