Efficacy of cone-beam computed tomography with modified gray-scale range versus digital periapical radiography for the assessment of bone-implant interface gaps

被引:0
作者
Kajan, Zahra Dalili [1 ]
Abbasi, Sara [2 ]
Khosravifard, Negar [1 ]
Sigaroudi, Ali Khalighi [3 ]
Motevasseli, Safa [3 ]
机构
[1] Guilan Univ Med Sci, Dent Sci Res Ctr, Sch Dent, Dept Maxillofacial Radiol, Rasht, Iran
[2] Guilan Univ Med Sci, Sch Dent, Dept Maxillofacial Radiol, Rasht, Iran
[3] Guilan Univ Med Sci, Sch Dent, Dept Maxillofacial Surg, Rasht, Iran
关键词
Dental implantation; Cone-beam computed tomography; Radiography; Dental; Digital; Osseointegration;
D O I
10.1007/s11282-021-00529-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To compare the efficacy of digital periapical (PA) radiography with cone-beam computed tomography (CBCT) by altering the gray-scale range for the detection of bone-implant interface gaps. Methods Titanium implants were placed in 52 blocks of bovine rib such that 42 had no gaps and served as the control group. The implants were subsequently placed in the same blocks with 0.25 mm increase in the osteotomy size to serve as the test group. The remaining 10 blocks were used for random arrangement of the test and control blocks within a fabricated wax arch. CBCT with change in the gray-scale range and digital PA were obtained and evaluated by two observers regarding the presence/absence of gaps. The two imaging modalities were compared by the receiver operating characteristic (ROC) curve, Kappa and McNemar tests (alpha = 0.05). Results PA and CBCT showed moderate agreement for gap detection (k = 0.60). There were no significant differences in the area under the ROC curve (AUC) between CBCT and PA (P = 0.45). The frequency of correct diagnoses on PA radiographs was significantly higher in the test group (P = 0.016), while not significant on the CBCT images (P = 0.344). PA showed higher sensitivity (100%) compared to CBCT (83.33%). However, the specificity of CBCT (92.86%) was greater than that of PA (83.33%). Conclusions Certain gray-scale ranges in CBCT enhance the assessment of bone-implant interface which brings the accuracy of CBCT closer to digital PA radiography as the modality of choice.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 19 条
[1]   Evaluation of the success rate of cone beam computed tomography in determining the location and direction of screw access holes in cement-retained implant-supported prostheses: An in vitro study [J].
Asli, Hamid Neshandar ;
Kajan, Zahra Dalili ;
Gholizade, Fatemeh .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02) :220-224
[2]  
Asli HN., 2020, INT J PROSTHODONT
[3]   Cone Beam Computed Tomography in Implant Dentistry: A Systematic Review Focusing on Guidelines, Indications, and Radiation Dose Risks [J].
Bornstein, Michael M. ;
Scarfe, William C. ;
Vaughn, Vida M. ;
Jacobs, Reinhilde .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :55-77
[4]  
Branemark PI., 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[5]   Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard [J].
Corpas, Livia dos Santos ;
Jacobs, Reinhilde ;
Quirynen, Marc ;
Huang, Yan ;
Naert, Ignace ;
Duyck, Joke .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) :492-499
[6]   A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects [J].
Dave, Meetal ;
Davies, Jonathan ;
Wilson, Ron ;
Palmer, Richard .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) :671-678
[7]  
Dobbs M B, 1999, Iowa Orthop J, V19, P43
[8]   Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption [J].
Durack, C. ;
Patel, S. ;
Davies, J. ;
Wilson, R. ;
Mannocci, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) :136-147
[9]   Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Leles, Claudio Rodrigues ;
Azevedo, Bruno ;
Azevedo, Jose Ribamar .
JOURNAL OF ENDODONTICS, 2008, 34 (03) :273-279
[10]   Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study [J].
Hilgenfeld, Tim ;
Juerchott, Alexander ;
Deisenhofer, Ulrich Karl ;
Krisam, Johannes ;
Rammelsberg, Peter ;
Heiland, Sabine ;
Bendszus, Martin ;
Schwindling, Franz Sebastian .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) :922-930