Simulation tools to assess microclimate and building energy - A case study on the design of a new district

被引:71
作者
Gros, Adrien [1 ,2 ]
Bozonnet, Emmanuel [1 ,2 ]
Inard, Christian [1 ,2 ]
Musy, Marjorie [2 ,3 ]
机构
[1] Univ La Rochelle, CNRS, LaSIE, UMR 7356, F-17000 La Rochelle, France
[2] Inst Rech Sci & Tech Vile, Paris, France
[3] Ecole Natl Super Architecture Nantes, UMR 1563, CERMA, Nantes, France
关键词
Building energy simulation; Urban microclimate; District design; Urban heat island; URBAN HEAT-ISLAND; CONSUMPTION; MODEL; CLIMATE; PERFORMANCE; ENVIRONMENT; IMPACT; OPTIMIZATION; TEMPERATURE; ALGORITHMS;
D O I
10.1016/j.enbuild.2015.06.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Since some years, dense cities and compact buildings are promoted as sustainable and energy efficient designs. Nevertheless, urban planning strategies should take into account the interactions between buildings and the Microclimate because the Urban Heat Island (UHI) phenomenon can increase the cooling load of buildings and is strongly influenced by urban morphology, urban landscaping and the thermal properties of buildings and soil. The modification of these parameters, such as building density, can mitigate UHI, with direct and indirect improvement of building energy performances. The case study presented in this paper concerns a new district in La Rochelle (France) named Atlantech. Currently at the design stage, the goal is to transform this old military camp into a zero carbon district. This study was performed in parallel with urban planning using EnviBatE and SOLENE-Microclimate simulation. Two building densities are compared through the impacts on solar irradiance, wind airflows, building indoor temperatures and energy demand. Analysis of reference and densified district highlights various impacts such as the wind velocity decrease, up to 80%, and the effect on an existing nearby building solar irradiation, reduced by 7%. These results underline the potential usefulness of these simulation tools for urban planners at the design stage. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 62 条
[1]   Peak power and cooling energy savings of high-albedo roofs [J].
Akbari, H ;
Bretz, S ;
Kurn, DM ;
Hanford, J .
ENERGY AND BUILDINGS, 1997, 25 (02) :117-126
[2]  
[Anonymous], 2013, INT J LOW CARBON TEC
[3]  
[Anonymous], OECD REGIONAL DEV WO
[4]  
[Anonymous], 1998, FAO IRRIG DRAIN PAPE
[5]  
Archambeau F., 2004, International Journal on Finite Volumes, V1, P1
[6]   Thermal design tool for outdoor spaces based on heat balance simulation using a 3D-CAD system [J].
Asawa, Takashi ;
Hoyano, Akira ;
Nakaohkubo, Kazuaki .
BUILDING AND ENVIRONMENT, 2008, 43 (12) :2112-2123
[7]  
Athamena K., 2012, MODELISATION SIMULAT
[8]  
Bouyer J., 2009, Modelisation et simulation des microclimats urbains-Etude de l'impact de l'amenagement urbain sur les consommations energetiques des batiments
[9]   Microclimatic coupling as a solution to improve building energy simulation in an urban context [J].
Bouyer, Julien ;
Inard, Christian ;
Musy, Marjorie .
ENERGY AND BUILDINGS, 2011, 43 (07) :1549-1559
[10]  
Bowker G.E., 2004, 5 S URB ENV VANC BC