Operation and performance of the CMS Resistive Plate Chambers during LHC run II

被引:0
作者
Eysermans, Jan [1 ]
Pedraza Morales, Maria Isabel [1 ]
机构
[1] Benemerita Univ Autonoma Puebla, Fac Ciencias Fis Matemat, Puebla, Mexico
来源
31ST ANNUAL MEETING OF THE DIVISION OF PARTICLES AND FIELDS (DPYC) OF THE MEXICAN PHYSICAL SOCIETY | 2017年 / 912卷
关键词
D O I
10.1088/1742-6596/912/1/012015
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The Resistive Plate Chambers (RPC) at the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC) provide redundancy to the Drift Tubes in the barrel and Cathode Strip Chambers in the endcap regions. Consisting of 1056 double gap RPC chambers, the main detector parameters and environmental conditions are carefully monitored during the data taking period. At a center of mass energy of 13 TeV, the luminosity reached record levels which were challenging from the operational and performance point of view. In this work, the main operational parameters are discussed and the overall performance of the RPC system is reported for the LHC run II data taking period. With a low amount of inactive chambers, a good and stable detector performance was achieved with high efficiency.
引用
收藏
页数:5
相关论文
共 50 条
[41]   Calibration and Performance of the CMS Electromagnetic Calorimeter During LHC Run 3 [J].
Zhang, Jie .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (07) :2045-2047
[42]   The CMS Muon System: performance during the LHC Run-2 [J].
Pozzobon, N. .
JOURNAL OF INSTRUMENTATION, 2019, 14
[43]   Production and Performance of RE4 Resistive Plate Chambers for CMS experiment upgrade [J].
Jeong, Min Soo ;
Lee, Kyong Sei ;
Park, Sung Keun .
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
[44]   Assembly and Characterization of Resistive Plate Chambers in India for the CMS Detector [J].
Kumar, R. ;
Mehta, A. ;
Bhatnagar, V. ;
Singh, J. B. ;
Chudasama, R. ;
Mohanty, A. K. ;
Pant, L. M. ;
Sehgal, R. ;
Sehgal, S. T. ;
Thomas, R. G. .
XXI DAE-BRNS HIGH ENERGY PHYSICS SYMPOSIUM, 2016, 174 :553-557
[45]   A prototype front end chip for the CMS resistive plate chambers [J].
Abbrescia, M ;
Colaleo, A ;
Guarrasi, L ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Altieri, S ;
Belli, G ;
Bruno, G ;
Gianini, G ;
Ratti, SP ;
Riccardi, C ;
Torre, P ;
Viola, L ;
Vitulo, P .
PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, :457-461
[46]   Fluoride production in CMS Resistive Plate Chambers and aging study [J].
Gelmi, A. ;
Miguel, O. ;
Kumari, P. ;
Guida, R. ;
Mandelli, B. .
EUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2019, 2020,
[47]   Operation and performance of the CMS Electromagnetic Calorimeter during the 2010 run [J].
Di Matteo, L. .
NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2011, 34 (06) :300-302
[48]   Performance of CMS Tracker Alignment during LHC Run 2 and Commissioning towards Run 3 [J].
Pramod, Lakshmi .
20TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH, 2023, 2438
[49]   Performance of the ATLAS resistive plate chambers [J].
Cattani, Giordano .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 :S6-S9
[50]   CMS ECAL monitoring and calibration in LHC Run II [J].
Mudholkar, Tanmay .
18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162