Operation and performance of the CMS Resistive Plate Chambers during LHC run II

被引:0
作者
Eysermans, Jan [1 ]
Pedraza Morales, Maria Isabel [1 ]
机构
[1] Benemerita Univ Autonoma Puebla, Fac Ciencias Fis Matemat, Puebla, Mexico
来源
31ST ANNUAL MEETING OF THE DIVISION OF PARTICLES AND FIELDS (DPYC) OF THE MEXICAN PHYSICAL SOCIETY | 2017年 / 912卷
关键词
D O I
10.1088/1742-6596/912/1/012015
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The Resistive Plate Chambers (RPC) at the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC) provide redundancy to the Drift Tubes in the barrel and Cathode Strip Chambers in the endcap regions. Consisting of 1056 double gap RPC chambers, the main detector parameters and environmental conditions are carefully monitored during the data taking period. At a center of mass energy of 13 TeV, the luminosity reached record levels which were challenging from the operational and performance point of view. In this work, the main operational parameters are discussed and the overall performance of the RPC system is reported for the LHC run II data taking period. With a low amount of inactive chambers, a good and stable detector performance was achieved with high efficiency.
引用
收藏
页数:5
相关论文
共 50 条
[31]   CMS Electromagnetic Calorimeter performance during the 2011 LHC run [J].
Montanino, D. .
NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2013, 36 (01) :269-270
[32]   CMS Detector Performance during LHC Run 1 and projections for Run 2 [J].
Goy Lopez, Silvia .
NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 :1048-1054
[33]   Performance and longevity of CO2 based mixtures in CMS improved Resistive Plate Chambers in the HL-LHC environment [J].
Pinheiro, J. P. ;
Tytgat, M. ;
Amarilo, K. Mota ;
Samalan, A. ;
Skovpen, K. ;
Alves, G. A. ;
Coelho, E. Alves ;
Silva, F. Marujo da ;
Filho, M. Barroso Ferreira ;
Da Costa, E. M. ;
Damiao, D. De Jesus ;
Ferreira, B. C. ;
Souza, S. Fonseca De ;
Mundim, L. ;
Nogima, H. ;
Santoro, A. ;
Thiel, M. ;
Souza, R. Gomes De ;
Monteiro, T. De Andrade rangel ;
Aleksandrov, A. ;
Hadjiiska, R. ;
Iaydjiev, P. ;
Shopova, M. ;
Sultanov, G. ;
Dimitrov, A. ;
Litov, L. ;
Pavlov, B. ;
Petkov, P. ;
Petrov, A. ;
Shumka, E. ;
Cao, P. ;
Diao, W. ;
Gong, W. ;
Hou, Q. ;
Kou, H. ;
Liu, Z. -a. ;
Song, J. ;
Wang, N. ;
Zhao, J. ;
Qian, S. J. ;
Avila, C. ;
Trujillo, D. A. Barbosa ;
Cabrera, A. ;
Florez, C. A. ;
Vega, J. A. Reyes ;
Aly, R. ;
Radi, A. ;
Assran, Y. ;
Crotty, I. ;
Mahmoud, M. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1076
[34]   HF production in CMS-resistive plate chambers [J].
Abbrescia, M. ;
Colaleo, A. ;
Guida, R. ;
Iaselli, G. ;
Loddo, F. ;
Maggi, M. ;
Marangelli, B. ;
Natali, S. ;
Nuzzo, S. ;
Pugliese, G. ;
Ranieri, A. ;
Romano, F. ;
Trentadue, R. ;
Cavallo, N. ;
Fabozzi, F. ;
Paolucci, P. ;
Piccolo, D. ;
Polese, G. ;
Sciacca, C. ;
Belli, G. ;
Necchi, M. ;
Ratti, S. ;
Riccardi, C. ;
Torre, P. ;
Vitulo, P. ;
Anguelov, T. ;
Genchev, V. ;
Panev, B. ;
Piperov, S. ;
Sultanov, G. ;
Vankov, P. ;
Litov, L. ;
Pavlov, B. ;
Petkov, P. .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 158 :30-34
[35]   Aging studies for the CMS improved Resistive Plate Chambers [J].
Ferreira Filho, M. Barroso ;
Samalan, A. ;
Tytgat, M. ;
El Sawy, M. ;
Alves, G. A. ;
Marujo, F. ;
Coelho, E. A. ;
Da Costa, E. M. ;
Nogima, H. ;
Santoro, A. ;
De Souza, S. Fonseca ;
Damiao, D. De Jesus ;
Thiel, M. ;
Amarilo, K. Mota ;
Aleksandrov, A. ;
Hadjiiska, R. ;
Iaydjiev, P. ;
Rodozov, M. ;
Shopova, M. ;
Soultanov, G. ;
Dimitrov, A. ;
Litov, L. ;
Pavlov, B. ;
Petkov, P. ;
Petrov, A. ;
Shumka, E. ;
Qian, S. J. ;
Kou, H. ;
Liu, Z. -A. ;
Zhao, J. ;
Song, J. ;
Hou, Q. ;
Diao, W. ;
Cao, P. ;
Avila, C. ;
Barbosa, D. ;
Cabrera, A. ;
Florez, A. ;
Fraga, J. ;
Reyes, J. ;
Assran, Y. ;
Mahmoud, M. A. ;
Mohammed, Y. ;
Crotty, I. ;
Laktineh, I. ;
Grenier, G. ;
Gouzevitch, M. ;
Mirabito, L. ;
Shchablo, K. ;
Bagaturia, I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1055
[36]   The Resistive Plate Chamber system for the CMS experiment at LHC [J].
Abbrescia, Marcello .
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, :1461-1465
[37]   Performance of the CMS ECAL data acquisition system at LHC Run II [J].
Wamorkar, Tanvi .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 :346-348
[38]   Calibration and performance of the CMS Electromagnetic Calorimeter in LHC Run-II [J].
Kuo, C. M. .
JOURNAL OF INSTRUMENTATION, 2020, 15 (06)
[39]   The CMS Calorimeter Trigger for LHC Run II [J].
Bundock, Aaron .
17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
[40]   Long-term performance and longevity studies o the CMS Resistive Plate Chambers [J].
Rabadan-Trejo, R. I. ;
Fagot, A. ;
Gul, M. ;
Roskas, C. ;
Tytgat, M. ;
Zaganidis, N. ;
Fonseca De Souza, S. ;
Santoro, A. ;
Torres Da Silva De Araujo, F. ;
Aleksandrov, A. ;
Hadjiiska, R. ;
Iaydjiev, P. ;
Rodozov, M. ;
Shopova, M. ;
Sultanov, G. ;
Dimitrov, A. ;
Litov, L. ;
Pavlov, B. ;
Petkov, P. ;
Petrov, A. ;
Qian, S. J. ;
Han, D. ;
Yi, W. ;
Avila, C. ;
Cabrera, A. ;
Carrillo, C. ;
Segura, M. ;
Aly, S. ;
Assran, Y. ;
Mahrous, A. ;
Mohamed, A. ;
Combaret, C. ;
Gouzevitch, M. ;
Grenier, G. ;
Lagarde, F. ;
Laktineh, I. B. ;
Mathez, H. ;
Mirabito, L. ;
Shchablo, K. ;
Bagaturia, I. ;
Lomidze, D. ;
Lomidze, I. ;
Pant, L. M. ;
Bhatnagar, V. ;
Gupta, R. ;
Kumari, R. ;
Lohan, M. ;
Singh, J. B. ;
Amoozegar, V. ;
Boghrati, B. .
JOURNAL OF INSTRUMENTATION, 2018, 13