Multimodal ophthalmic imaging using spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

被引:0
作者
El-Haddad, Mohamed T. [1 ]
Malone, Joseph D. [1 ]
Li, Jianwei D. [1 ]
Bozic, Ivan [1 ]
Arquitola, Amber M. [1 ]
Joos, Karen M. [1 ,2 ]
Patel, Shriji N. [2 ]
Tao, Yuankai K. [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Ophthalmol & Visual Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
来源
BIOSENSING AND NANOMEDICINE X | 2017年 / 10352卷
基金
美国国家卫生研究院;
关键词
multimodal imaging; ophthalmic imaging; optical coherence tomography; scanning laser ophthalmoscopy; intraoperative imaging; ophthalmic surgical guidance; augmented-reality; SWEPT-SOURCE; SURGERY; OCT;
D O I
10.1117/12.2275552
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Ophthalmic surgery involves manipulation of delicate, layered tissue structures on milli- to micrometer scales. Traditional surgical microscopes provide an inherently two-dimensional view of the surgical field with limited depth perception which precludes accurate depth-resolved visualization of these tissue layers, and limits the development of novel surgical techniques. We demonstrate multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (SS-SESLO-OCT) to address current limitations of image-guided ophthalmic microsurgery. SS-SESLO-OCT provides inherently co-registered en face and cross-sectional field-of-views (FOVs) at a line rate of 400 kHz and > 2 GPix/s throughput. We show in vivo imaging of the anterior segment and retinal fundus of a healthy volunteer, and preliminary results of multi-volumetric mosaicking for ultrawide-field retinal imaging with 90 degrees FOV. Additionally, a scan-head was rapid-prototyped with a modular architecture which enabled integration of SS-SESLO-OCT with traditional surgical microscope and slit-lamp imaging optics. Ex vivo surgical maneuvers were simulated in cadaveric porcine eyes. The system throughput enabled volumetric acquisition at 10 volumes-per-second (vps) and allowed visualization of surgical dynamics in corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. SESLO en face images enabled simple real-time co-registration with the surgical microscope FOV, and OCT cross-sections provided depth-resolved visualization of instrument-tissue interactions. Finally, we demonstrate novel augmented-reality integration with the surgical view using segmentation overlays to aid surgical guidance. SS-SESLO-OCT may benefit clinical diagnostics by enabling aiming, registration, and mosaicking; and intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted biomarkers of disease.
引用
收藏
页数:6
相关论文
共 14 条
  • [1] FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Binder, Susanne
    Falkner-Radler, Christiane I.
    Hauger, Christoph
    Matz, Holger
    Glittenberg, Carl
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (07): : 1332 - 1336
  • [2] Use of Handheld Intraoperative Spectral-Domain Optical Coherence Tomography in a Variety of Vitreoretinal Diseases
    Branchini, Lauren A.
    Gurley, Kiersten
    Duker, Jay S.
    Reichel, Elias
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (01) : 49 - 54
  • [3] Determination of Feasibility and Utility of Microscope-Integrated Optical Coherence Tomography During Ophthalmic Surgery The DISCOVER Study RESCAN Results
    Ehlers, Justis P.
    Goshe, Jeff
    Dupps, William J.
    Kaiser, Peter K.
    Singh, Rishi P.
    Gans, Richard
    Eisengart, Jonathan
    Srivastava, Sunil K.
    [J]. JAMA OPHTHALMOLOGY, 2015, 133 (10) : 1124 - 1132
  • [4] The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg With Optical CoherEncE TomogRaphy (PIONEER) Study: 2-Year Results
    Ehlers, Justis P.
    Dupps, William J.
    Kaiser, Peter K.
    Goshe, Jeff
    Singh, Rishi P.
    Petkovsek, Daniel
    Srivastava, Sunil K.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (05) : 999 - 1007
  • [5] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [6] Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
    Klein, Thomas
    Wieser, Wolfgang
    Eigenwillig, Christoph M.
    Biedermann, Benjamin R.
    Huber, Robert
    [J]. OPTICS EXPRESS, 2011, 19 (04): : 3044 - 3062
  • [7] Use of Intraoperatiye Fourier-Domain Anterior Segment Optical Coherence Tomography During Descemet Stripping Endothelial Keratoplasty
    Knecht, Pascal B.
    Kaufmann, Claude
    Menke, Marcel N.
    Watson, Stephanie L.
    Bosch, Martina M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (03) : 360 - 365
  • [8] Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography
    Malone, Joseph D.
    El-Haddad, Mohamed T.
    Bozic, Ivan
    Tye, Logan A.
    Majeau, Lucas
    Godbout, Nicolas
    Rollins, Andrew M.
    Boudoux, Caroline
    Joos, Karen M.
    Patel, Shriji N.
    Tao, Yuankai K.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01): : 193 - 206
  • [9] Multimodal ophthalmic imaging using swept source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography
    Malone, Joseph D.
    El-Haddad, Mohamed T.
    Tye, Logan A.
    Majeau, Lucas
    Godbout, Nicolas
    Rollins, Andrew M.
    Boudoux, Caroline
    Tao, Yuankai K.
    [J]. OPHTHALMIC TECHNOLOGIES XXVI, 2016, 9693
  • [10] Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
    Potsaid, Benjamin
    Baumann, Bernhard
    Huang, David
    Barry, Scott
    Cable, Alex E.
    Schuman, Joel S.
    Duker, Jay S.
    Fujimoto, James G.
    [J]. OPTICS EXPRESS, 2010, 18 (19): : 20029 - 20048