Two years outcome in patients with persistent atrial fibrillation after pulmonary vein isolation using the second-generation 28-mm cryoballoon

被引:41
作者
Tscholl, Verena [1 ]
Lsharaf, Abdullah Khaled-A. [1 ]
Lin, Tina [2 ]
Bellmann, Barbara [1 ]
Biewener, Sebastian [1 ]
Nagel, Patrick [1 ]
Suhail, Saba [1 ]
Lenz, Klaus [3 ]
Landmesser, Ulf [1 ]
Roser, Mattias [1 ]
Rillig, Andreas [1 ]
机构
[1] Charite Univ Med Berlin, Dept Cardiol, Campus Benjamin Franklin,Hindenburgdamm 30, Berlin, Germany
[2] Genesis Care, Heart Care Victoria, Melbourne, Vic, Australia
[3] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Campus Benjamin Franklin, Berlin, Germany
关键词
Catheter ablation; Cryoballon ablation; Persistent atrial fibrillation; Long-term outcome; Second generation; Efficacy; RADIOFREQUENCY CATHETER ABLATION; OBSTRUCTIVE SLEEP-APNEA; INDEX PROCEDURE; FOLLOW-UP; EFFICACY; SAFETY; 1ST;
D O I
10.1016/j.hrthm.2016.05.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The efficacy of the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in patients with persistent AF are sparse. OBJECTIVE The aim of this study was to evaluate the 2-year success rate of pulmonary vein isolation in patients with persistent AF using the second-generation CB. METHODS Fifty consecutive patients (mean age 64.6 +/- 9.9 years; 19 women [38%]) with persistent AF were included in this analysis. The mean follow-up period was 22 11 months. All patients were ablated using the second-generation 28-mm CB. Isolation of the pulmonary veins was confirmed using a spiral mapping catheter. In all patients, follow-up was obtained using 24-hour Hotter monitoring or via interrogation of an implanted loop recorder or pacemaker. RESULTS The mean left atrial diameter was 43.6 +/- 5.6 mm, the mean CHA(2)DS(2)-VASc score was 2.8 +/- 1.5, and the mean HAS-BLED score was 2.1 +/- 1.2. The mean fluoroscopy time was 25.8 +/- 9 minutes, and the mean procedural time was 146.4 +/- 37.8 minutes. After 22 +/- 11 months, the frequency of arrhythmia recurrence was 22 of 50 (44%) in the overall group (paroxysmal AF 6 of 22 [27%]; persistent AF 16 of 22 [73%]). No major complications occurred. Aneurysma spurium not requiring surgical intervention occurred in 1 (2%) patient. No phrenic nerve palsy was observed. CONCLUSION Two years' results after pulmonary vein isolation using the second-generation CB in patients with persistent AF are promising. The clinical success rate appears to be similar to the reported success rates of radiofrequency ablation for the treatment of persistent AF. (C) 2016 Heart Rhythm Society. All rights reserved.
引用
收藏
页码:1817 / 1822
页数:6
相关论文
共 24 条
[1]   Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies [J].
Andrade, Jason G. ;
Khairy, Paul ;
Guerra, Peter G. ;
Deyell, Marc W. ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Dubuc, Marc .
HEART RHYTHM, 2011, 8 (09) :1444-1451
[2]   2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design [J].
Calkins, Hugh ;
Kuck, Karl Heinz ;
Cappato, Riccardo ;
Brugada, Josep ;
Camm, A. John ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
DiMarco, John ;
Edgerton, James ;
Ellenbogen, Kenneth ;
Ezekowitz, Michael D. ;
Haines, David E. ;
Haissaguerre, Michel ;
Hindricks, Gerhard ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jalife, Jose ;
Jais, Pierre ;
Kalman, Jonathan ;
Keane, David ;
Kim, Young-Hoon ;
Kirchhof, Paulus ;
Klein, George ;
Kottkamp, Hans ;
Kumagai, Koichiro ;
Lindsay, Bruce D. ;
Mansour, Moussa ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koonlawee ;
Nakagawa, Hiroshi ;
Natale, Andrea ;
Nattel, Stanley ;
Packer, Douglas L. ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Reddy, Vivek ;
Ruskin, Jeremy N. ;
Shemin, Richard J. ;
Tsao, Hsuan-Ming ;
Wilber, David ;
Ad, Niv ;
Cummings, Jennifer ;
Gillinov, A. Mark ;
Heidbuchel, Hein .
EUROPACE, 2012, 14 (04) :528-606
[3]   Catheter ablation for atrial fibrillation in patients with obesity [J].
Cha, Yong-Mei ;
Friedman, Paul A. ;
Asirvatham, Samuel J. ;
Shen, Win-Kuang ;
Munger, Thomas M. ;
Rea, Robert F. ;
Brady, Peter A. ;
Jahangir, Arshad ;
Monahan, Kristi H. ;
Hodge, David O. ;
Meverden, Ryan A. ;
Gersh, Bernard J. ;
Hammill, Stephen C. ;
Packer, Douglas L. .
CIRCULATION, 2008, 117 (20) :2583-2590
[4]   Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up [J].
Chierchia, Gian-Battista ;
Di Giovanni, Giacomo ;
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Conte, Giulio ;
Sieira-Moret, Juan ;
Rodriguez-Manero, Moises ;
Casado, Ruben ;
Baltogiannis, Giannis ;
Namdar, Mehdi ;
Saitoh, Yukio ;
Paparella, Gaetano ;
Mugnai, Giacomo ;
Brugada, Pedro .
EUROPACE, 2014, 16 (05) :639-644
[5]   A Prospective Study Evaluating the Role of Obesity and Obstructive Sleep Apnea for Outcomes After Catheter Ablation of Atrial Fibrillation [J].
Chilukuri, Karuna ;
Dalal, Darshan ;
Gadrey, Shrirang ;
Marine, Joseph E. ;
MacPherson, Edwin ;
Henrikson, Charles A. ;
Cheng, Alan ;
Nazarian, Saman ;
Sinha, Sunil ;
Spragg, David ;
Berger, Ronald ;
Calkins, Hugh .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (05) :521-525
[6]   Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation [J].
Ciconte, Giuseppe ;
Baltogiannis, Giannis ;
de Asmundis, Carlo ;
Sieira, Juan ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Mugnai, Giacomo ;
Hunuk, Burak ;
Chierchia, Gian-Battista ;
Brugada, Pedro .
EUROPACE, 2015, 17 (04) :559-565
[7]   Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon [J].
Ciconte, Giuseppe ;
Ottaviano, Luca ;
Deasmundis, Carlo ;
Baltogiannis, Giannis ;
Conte, Giulio ;
Sieira, Juan ;
Di Giovanni, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Mugnai, Giacomo ;
Storti, Cesare ;
Montenero, Annibale Sandro ;
Chierchia, Gian-Battista ;
Brugada, Pedro .
HEART RHYTHM, 2015, 12 (01) :60-66
[8]   One-Year Follow-Up After Single Procedure Cryoballoon Ablation: A Comparison Between the First and Second Generation Balloon [J].
Di Giovanni, Giacomo ;
Wauters, Kristel ;
Chierchia, Gian-Battista ;
Sieira, Juan ;
Levinstein, Moises ;
Conte, Giulio ;
De Asmundis, Carlo ;
Baltogiannis, Giannis ;
Saitoh, Yukio ;
Ciconte, Giuseppe ;
Julia, Justo ;
Mugnai, Giacomo ;
Irfan, Ghazala ;
Brugada, Pedro .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (08) :834-839
[9]   Incidence and characteristics of phrenic nerve palsy following pulmonary vein isolation with the second-generation as compared with the first-generation cryoballoon in 360 consecutive patients [J].
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Schmidt, Boris ;
Perrotta, Laura ;
Dugo, Daniela ;
De lazzari, Manuel ;
Schulte-Hahn, Britta ;
Nowak, Bernd ;
Chun, Julian K. R. .
EUROPACE, 2015, 17 (04) :574-578
[10]   Improved 1-Year Clinical Success Rate of Pulmonary Vein Isolation with the Second-Generation Cryoballoon in Patients with Paroxysmal Atrial Fibrillation [J].
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Dugo, Daniela ;
Perotta, Laura ;
Gunawardene, Melanie ;
Schulte-Hahn, Britta ;
Nowak, Bernd ;
Schmidt, Boris ;
Chun, Julian K. R. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (08) :840-844