Microstructural investigation to the controlled release kinetics of monolith osmotic pump tablets via synchrotron radiation X-ray microtomography

被引:59
|
作者
Li, Haiyan [1 ]
Yin, Xianzhen [1 ]
Ji, Junqiu [2 ]
Sun, Lixin [3 ]
Shao, Qun [4 ]
York, Peter [4 ]
Xiao, Tiqiao [5 ]
He, You [5 ]
Zhang, Jiwen [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Mat Med, Ctr Drug Delivery Syst, Shanghai 201203, Peoples R China
[2] Hefei Lifeon Medicat Grp, Hefei 230088, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Pharm, Shenyang 110016, Peoples R China
[4] Univ Bradford, Inst Pharmaceut Innovat, Bradford BD7 1DP, W Yorkshire, England
[5] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai Synchrotron Radiat Facil, Shanghai 201204, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Osmotic drug delivery system; Synchrotron radiation X-ray computed; Microtomography; Three dimensional reconstruction; Drug release kinetics; Surface area; DRUG-DELIVERY; SYSTEM; NIFEDIPINE;
D O I
10.1016/j.ijpharm.2012.02.017
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Tomographic imaging techniques are attractive tools for the visualization of the internal structural characteristics of pharmaceutical solid dosage forms. In this paper, the internal structure of the tablet core for a monolith osmotic drug delivery system, felodipine sustained-release tablet, was visualized via synchrotron radiation X-ray computed microtomography during the drug release process. The surface areas and three dimensional parameters of the tablet core were calculated based on the three dimensional reconstruction of the images. At different stages of the drug release process, the surface morphology, the hydration, the swelling, and the structure changing of the tablet, were visualized from the two dimensional monochrome X-ray images. The three dimensional volumes of the remaining tablet core correlated well with the percentages of felodipine (R = 0.9988). Also, the three dimensional surface area almost unchanged during the drug release process, which clearly demonstrated the intrinsic drug release mechanism of the osmotic drug delivery system. In conclusion, the synchrotron radiation X-ray computed microtomography, with rapid acquisition, high intensity and micro-scale spatial resolution, was found to be a useful tool for the quantitative elucidation of the intrinsic drug release kinetics and the three dimensional parameters such as surface areas of the remained core obtained by the synchrotron radiation. Thus, X-ray computed microtomography can be considered as a new and complimentary analytical tool to standard compendial pharmaceutical tests for quality control of osmotic drug delivery systems. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 13 条
  • [1] X-ray transmission microtomography using synchrotron radiation
    Lopes, RT
    Rocha, HS
    de Jesus, EFO
    Barroso, RC
    de Oliveira, LF
    Anjos, MJ
    Braz, D
    Moreira, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) : 604 - 607
  • [2] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) : 75 - 79
  • [3] Microstructural investigation using synchrotron radiation X-ray microtomography reveals taste-masking mechanism of acetaminophen microspheres
    Guo, Zhen
    Yin, Xianzhen
    Liu, Congbiao
    Wu, Li
    Zhu, Weifeng
    Shao, Qun
    York, Peter
    Patterson, Laurence
    Zhang, Jiwen
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 499 (1-2) : 47 - 57
  • [4] Fractal structure determines controlled release kinetics of monolithic osmotic pump tablets
    Yin, Xianzhen
    Li, Haiyan
    Liu, Ruihao
    Chen, Jing
    Ji, Junqiu
    Chen, Jun
    Shao, Qun
    Xiao, Tiqiao
    York, Peter
    He, You
    Zhang, Jiwen
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2013, 65 (07) : 953 - 959
  • [5] Visualization and quantitative profiling of mixing and segregation of granules using synchrotron radiation X-ray microtomography and three dimensional reconstruction
    Liu, Ruihao
    Yin, Xianzhen
    Li, Haiyan
    Shao, Qun
    York, Peter
    He, You
    Xiao, Tiqiao
    Zhang, Jiwen
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 445 (1-2) : 125 - 133
  • [6] Quantification of Swelling and Erosion in the Controlled Release of a Poorly Water-Soluble Drug Using Synchrotron X-ray Computed Microtomography
    Xianzhen Yin
    Haiyan Li
    Zhen Guo
    Li Wu
    Fangwei Chen
    Marcel de Matas
    Qun Shao
    Tiqiao Xiao
    Peter York
    You He
    Jiwen Zhang
    The AAPS Journal, 2013, 15 : 1025 - 1034
  • [7] Quantification of Swelling and Erosion in the Controlled Release of a Poorly Water-Soluble Drug Using Synchrotron X-ray Computed Microtomography
    Yin, Xianzhen
    Li, Haiyan
    Guo, Zhen
    Wu, Li
    Chen, Fangwei
    de Matas, Marcel
    Shao, Qun
    Xiao, Tiqiao
    York, Peter
    He, You
    Zhang, Jiwen
    AAPS JOURNAL, 2013, 15 (04): : 1025 - 1034
  • [8] Analysis of wood microstructure by synchrotron radiation-based X-ray microtomography (SRμCT)
    Lautner, Silke
    Beckmann, Felix
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [9] Microstructural analysis of paper using synchrotron X-ray microtomography: numerical estimation of the permeability and effective thermal conductivity
    Du Roscoat, Sabine Rolland
    Decain, Maxime
    Geindreau, Christian
    Thibault, Xavier
    Bloch, Jean-Francis
    APPITA JOURNAL, 2008, 61 (04): : 286 - +
  • [10] Fast acquisition high-resolution synchrotron radiation X-ray microtomography for academic and industrial purposes
    Boller, E
    Cloetens, P
    Mokso, R
    Tafforeau, P
    Thibault, X
    Peyrin, F
    Marmottant, A
    Pernot, P
    Baruchel, J
    Computational Methods and Experiments in Materials Characterisation II, 2005, 51 : 197 - 206