A novel thin-film temperature and heat-flux microsensor for heat transfer measurements in microchannels

被引:15
作者
Hamadi, David [1 ]
Garnier, Bertrand [1 ]
Willaime, Herve [2 ]
Monti, Fabrice [2 ]
Peerhossaini, Hassan [1 ]
机构
[1] Univ Nantes, Ecole Polytech, UMR CNRS 6607, Lab Thermocinet, F-44306 Nantes, France
[2] CNRS ESPCI, Lab Microfluid MEMS & Nanostruct, F-75005 Paris, France
关键词
FORCED-CONVECTION; FLOW; WATER; MICROTUBES;
D O I
10.1039/c2lc20919e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Temperature and heat-flux measurement at the microscale for convective heat-transfer studies requires highly precise, minimally intrusive sensors. For this purpose, a new generic temperature and heat-flux sensor was designed, calibrated and tested. The sensor allows measurement of temperature and heat flux distributions along the direction of flow. It is composed of forty gold thermoresistances, 85 nm thick, deposited on both sides of a borosilicate substrate. Their sensitivities are about 37.8 mu VK-1, close to those of a K-type wire thermocouple. Using a thermoelectrical model, temperature biases due to the Joule effect were calculated using the current crossing each thermoresistance and the heat-transfer coefficient. Finally, heat-transfer measurements were performed with deionized water flowing in a straight PDMS microchannel for various Reynolds numbers. The Nusselt number was obtained for microchannels of 50 to 10 mu m span. The results were found to be in good agreement with classical Nu-Re macroscopic correlations.
引用
收藏
页码:652 / 658
页数:7
相关论文
共 36 条
[1]   An experimental investigation of single-phase forced convection in microchannels [J].
Adams, TM ;
Abdel-Khalik, SI ;
Jeter, SM ;
Qureshi, ZH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (6-7) :851-857
[2]   Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes [J].
Baier, V ;
Födisch, R ;
Ihring, A ;
Kessler, E ;
Lerchner, J ;
Wolf, G ;
Köhler, JM ;
Nietzsch, M ;
Krügel, M .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 :354-359
[3]   Bias effects on heat transfer measurements in microchannel flows [J].
Baviere, Roland ;
Favre-Marinet, Michel ;
Le Person, Stephane .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (19-20) :3325-3337
[4]  
Bejan A., 1993, HEAT TRANSFER
[5]   A high-temperature thermopile fabrication process for thermal flow sensors [J].
Buchner, Rainer ;
Sosna, Christoph ;
Maiwald, Marcus ;
Benecke, Wolfgang ;
Lang, Walter .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 :262-266
[6]   Fluid flow in microtubes with axial conduction including rarefaction and viscous dissipation [J].
Cetin, Barbaros ;
Yazicioglu, Almila Guvenc ;
Kakac, Sadik .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (05) :535-544
[7]  
Choi S.B., 1991, ASME DSC, V32, P123
[8]  
COLIN S, 2004, MICROFLUIDIQUE
[9]  
Cuta J.M., 1996, Advances in Energy Efficiency, Heat/Mass Transfer Enhancement, ASME-PID, 2/HTD, V338, P17
[10]  
Debray F., 2001, Mechanics and Industry, V2, P443