An examination of microwave heating to enhance diesel soot combustion

被引:14
作者
An, HM
Kilroy, C
McGinn, PJ [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
[2] Univ Notre Dame, Ctr Mol Eng Mat, Notre Dame, IN 46556 USA
关键词
oxide catalysts; diesel soot combustion; microwave heating; infrared thermography; particulate filter; thermogravimetric analysis;
D O I
10.1016/j.tca.2005.02.035
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of microwave heating on diesel soot combustion was studied through the use of a microwave heated thermogravimetric analyzer (TGA). A TGA was designed around a commercial multimode microwave oven so that carbon weight loss resulting from microwave heating could be measured. The oven door was modified, allowing infrared thermography to be used to measure soot combustion temperatures. Measurements suggest that the actual temperature of the oxidizing carbon (which is in the interior of the powder bed) is hotter than the surface temperature one measures by IR thermography. Thus, the apparent reduction in soot combustion temperature with microwave heating reported in some literature may be the result of the inability to measure the interior temperature of the soot/catalyst mass. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 26 条
[1]   Combinatorial synthesis and characterization of alkali metal doped oxides for diesel soot combustion [J].
An, HM ;
Kilroy, C ;
McGinn, PJ .
CATALYSIS TODAY, 2004, 98 (03) :423-429
[2]  
BABU VS, 1996, APPL OCCUP ENV HYG, V11, P799
[3]   High-temperature microwave processing of materials [J].
Bykov, YV ;
Rybakov, KI ;
Semenov, VE .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (13) :R55-R75
[4]   Microwaves assisted regeneration of catalytic filter for soot particulate [J].
Ciambelli, P ;
Palma, V ;
Russo, P ;
D'Amore, M .
SCIENCE AND TECHNOLOGY IN CATALYSIS 2002, 2003, 145 :367-370
[5]   Microwave processing of materials [J].
Clark, DE ;
Sutton, WH .
ANNUAL REVIEW OF MATERIALS SCIENCE, 1996, 26 :299-331
[6]   DESIGN AND CALIBRATION OF A CONTINUOUS TEMPERATURE-MEASUREMENT SYSTEM IN A MICROWAVE CAVITY BY INFRARED IMAGING [J].
GOEDEKEN, DL ;
TONG, CH ;
LENTZ, RR .
JOURNAL OF FOOD PROCESSING AND PRESERVATION, 1991, 15 (05) :331-337
[7]  
Ibarra JG, 1999, T ASAE, V42, P1383, DOI 10.13031/2013.13301
[8]   USE OF LOW-POWER AND HIGH-POWER MICROWAVE-ENERGY FOR THERMAL-ANALYSIS [J].
KARMAZSIN, E .
THERMOCHIMICA ACTA, 1987, 110 :289-295
[9]  
KARMAZSIN E, 1984, J THERM ANAL, V29, P1269
[10]   USE OF MICROWAVES IN THERMAL-ANALYSIS [J].
KARMAZSIN, E ;
BARHOUMI, R ;
SATRE, P ;
GAILLARD, F .
JOURNAL OF THERMAL ANALYSIS, 1985, 30 (01) :43-47