Evaluation of a μCT-based electro-anatomical cochlear implant model

被引:2
|
作者
Cakir, Ahmet [1 ]
Dawant, Benoit M. [1 ]
Noble, Jack. H. [1 ]
机构
[1] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37235 USA
来源
MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2016年 / 9786卷
关键词
Cochlear implant; modeling; image-guided cochlear implant programming;
D O I
10.1117/12.2217275
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cochlear implants (CIs) are considered standard treatment for patients who experience sensory-based hearing loss. Although these devices have been remarkably successful at restoring hearing, it is rare to achieve natural fidelity, and many patients experience poor outcomes. Previous studies have shown that outcomes can be improved when optimizing CI processor settings using an estimation of the CI's neural activation patterns found by detecting the distance between the CI electrodes and the nerves they stimulate in pre- and post-implantation CT images. We call this method Image-Guided CI Programming (IGCIP). More comprehensive electro-anatomical models (EAMs) might better estimate neural activation patterns than using a distance-based estimate, potentially leading to selecting further optimized CI settings. Our goal in this study is to investigate whether mu CT-based EAMs can accurately estimate neural stimulation patterns. For this purpose, we have constructed EAMs of N=9 specimens. We analyzed the sensitivity of our model to design parameters such as field-of-view, resolution, and tissue resistivity. Our results show that our model is stable to parameter changes. To evaluate the utility of patient-specific modeling, we quantify the difference in estimated neural activation patterns across specimens for identically located electrodes. The average computed coefficient of variation (COV) across specimens is 0.186, suggesting patient-specific models are necessary and that the accuracy of a generic model would be insufficient. Our results suggest that development of in vivo patient-specific EAMs could lead to better methods for selecting CI settings, which would ultimately lead to better hearing outcomes with CIs.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Temporal bone CT-based anatomical parameters associated with the development of cholesteatoma
    Cavaliere, Michele
    Ugga, Lorenzo
    Monfregola, Armando
    Cavaliere, Fabrizia
    Caranci, Ferdinando
    Russo, Carmela
    Briganti, Francesco
    Elefante, Andrea
    RADIOLOGIA MEDICA, 2023, 128 (09): : 1116 - 1124
  • [22] Cochlear Coordinates in Regard to Cochlear Implantation: A Clinically Individually Applicable 3 Dimensional CT-Based Method
    Verbist, Berit M.
    Joemai, Raoul M. S.
    Briaire, Jeroen J.
    Teeuwisse, Wouter M.
    Veldkamp, Wouter J. H.
    Frijns, Johan H. M.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (05) : 738 - 744
  • [23] In-vivo MRI and in-vivo electro-anatomical voltage map characteristics of infarct heterogeneity in a swine model
    Shokrollahi, E.
    Pop, M.
    Safri, M.
    Yang, Y.
    Radau, P. E.
    Barry, J.
    Detsky, J.
    Griffin, G. H.
    Crystal, E.
    Wright, G. A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2792 - 2795
  • [24] CT-based planning of implant surgery of interstitial brachytherapy in the breast cancer
    Schwedas, M.
    Weibert, K.
    Schrott, S.
    Fueller, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 97 - 97
  • [25] CT-BASED OPTIMIZED PLANNING FOR TRANSPERINEAL PROSTATE IMPLANT WITH CUSTOMIZED TEMPLATE
    ROY, JN
    WALLNER, KE
    CHIUTSAO, ST
    ANDERSON, LL
    LING, CC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (02): : 483 - 489
  • [26] Quantitative Analysis of Electro-Anatomical Maps: Application to an Experimental Model of Left Bundle Branch Block/Cardiac Resynchronization Therapy
    Iglesias, David Soto
    Duchateau, Nicolas
    Butakoff , Constantine
    Andreu, David
    Fernandez-Armenta, Juan
    Bijnens, Bart
    Berruezo, Antonio
    Sitges, Marta
    Camara, Oscar
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2017, 5
  • [27] Impact of post-implant evaluation by different slice intervals using CT-based dosimetry in prostate brachytherapy
    Tanaka, O.
    Matsuo, M.
    Hayashi, S.
    Maeda, S.
    Hoshi, H.
    EJC SUPPLEMENTS, 2005, 3 (02): : 254 - 255
  • [28] Safe and successful bone marrow biopsy: An anatomical and CT-based cadaver study
    Konda, Bhavana
    Pathak, Swati
    Edwin, Inga
    Mishall, Priti
    Downie, Sherry A.
    Olson, Todd R.
    Reed, Louis J.
    Friedman, Ellen W.
    AMERICAN JOURNAL OF HEMATOLOGY, 2014, 89 (10) : 943 - 946
  • [29] Establishment and evaluation of a CT-based radiomic model for AIDS-associated pulmonary cryptococcosis
    Zi-xin Zhang
    Xing-yu Mu
    Jing Yu
    Chun-shuang Guan
    Bu-dong Chen
    Ru-Ming Xie
    BMC Medical Imaging, 22
  • [30] Establishment and evaluation of a CT-based radiomic model for AIDS-associated pulmonary cryptococcosis
    Zhang, Zi-xin
    Mu, Xing-yu
    Yu, Jing
    Guan, Chun-shuang
    Chen, Bu-dong
    Xie, Ru-Ming
    BMC MEDICAL IMAGING, 2022, 22 (01)