The effects of early orthodontic force application on pulp test responses

被引:24
作者
Hall, CJ [1 ]
Freer, TJ [1 ]
机构
[1] Univ Queensland, Sch Dent, Brisbane, Qld 4000, Australia
关键词
pulp testing; orthodontic forces; response thresholds;
D O I
10.1111/j.1834-7819.1998.tb00189.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The effects of orthodontic tooth movement on pulpal responses are of interest to the clinician. Alterations to pulpal physiology may result in altered responses to external stimuli. This pilot project tested a small group of orthodontic patients during the early stages of treatment. Heat, cold and electrical stimuli were applied prior to treatment, after the placement of fixed appliances and after one month of force application. A smaller group was tested after two months of force application. One month after force application there was a lack of response to electrical stimulation but there was continued response to thermal stimulation. The lack of response to electrical stimulation continued in the smaller group up to two months. The results suggest that the outcome of electric pulp testing during orthodontic treatment should be interpreted cautiously. Thermal testing will offer more reliable data.
引用
收藏
页码:359 / 361
页数:3
相关论文
共 12 条
[1]   THE OPTIMUM PLACEMENT-SITE OF THE ELECTRODE IN ELECTRIC PULP TESTING OF THE 12 ANTERIOR TEETH [J].
BENDER, IB ;
LANDAU, MA ;
FONSECCA, S ;
TROWBRIDGE, HO .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1989, 118 (03) :305-310
[2]  
BURNSIDE RR, 1974, ANGLE ORTHOD, V44, P213
[3]   THE ROLE AND METHODS OF PULP TESTING IN ORAL-DIAGNOSIS - A REVIEW [J].
CHAMBERS, IG .
INTERNATIONAL ENDODONTIC JOURNAL, 1982, 15 (01) :1-15
[4]  
Dummer P M, 1980, Int Endod J, V13, P27, DOI 10.1111/j.1365-2591.1980.tb00834.x
[5]   A LABORATORY STUDY OF 4 ELECTRIC PULP TESTERS [J].
DUMMER, PMH ;
TANNER, M ;
MCCARTHY, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1986, 19 (04) :161-171
[6]   ASSESSMENT OF RELIABILITY OF ELECTRICAL AND THERMAL PULP TESTING AGENTS [J].
FUSS, Z ;
TROWBRIDGE, H ;
BENDER, IB ;
RICKOFF, B ;
SORIN, S .
JOURNAL OF ENDODONTICS, 1986, 12 (07) :301-305
[7]   THE EFFECT OF ORTHODONTIC FORCE APPLICATION ON THE PULPAL TISSUE RESPIRATION RATE IN THE HUMAN PREMOLAR [J].
HAMERSKY, PA ;
WEIMER, AD ;
TAINTOR, JF .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (04) :368-378
[8]  
Klein H, 1978, J DENT CHILD, V45, P199
[9]  
MARSHALL FJ, 1979, DENT CLIN N AM, V23, P495
[10]  
MCDONALD F, 1994, EUR J ORTHODONT, V16, P1