Analysis of magnetization transfer (MT) influence on quantitative mapping of T2 relaxation time

被引:25
作者
Radunsky, Dvir [1 ]
Blumenfeld-Katzir, Tamar [1 ]
Volovyk, Osnat [2 ]
Tal, Assaf [2 ]
Barazany, Daniel [3 ]
Tsarfaty, Galia [4 ]
Ben-Eliezer, Noam [1 ,5 ,6 ]
机构
[1] Tel Aviv Univ, Dept Biomed Engn, IL-6997801 Tel Aviv, Israel
[2] Weizmann Inst Sci, Dept Chem Phys, Rehovot, Israel
[3] Tel Aviv Univ, Strauss Computat Neuroimaging Ctr, Tel Aviv, Israel
[4] Sheba Med Ctr, Dept Diagnost Imaging, Ramat Gan, Israel
[5] Tel Aviv Univ, Sagol Sch Neurosci, Tel Aviv, Israel
[6] NYU, Langone Med Ctr, CAI2R, New York, NY USA
基金
以色列科学基金会;
关键词
magnetization transfer (MT); MRI signal models; multi spin-echo; quantitative MRI; T-2; mapping; relaxation; ECHO MRI TECHNIQUES; TRANSVERSE RELAXOMETRY; SPIN-LOCK; BRAIN; WATER; CONTRAST; ERRORS; UREA; QUANTIFICATION; LOCALIZATION;
D O I
10.1002/mrm.27704
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multi-echo spin-echo (MESE) protocol is the most effective tool for mapping T-2 relaxation in vivo. Still, MESE extensive use of radiofrequency pulses causes magnetization transfer (MT)-related bias of the water signal, instigated by the presence of macromolecules (MMP). Here, we analyze the effects of MT on MESE signal, alongside their impact on quantitative T-2 measurements. Methods: Study used 3 models: in vitro urea phantom, ex vivo horse brain, and in vivo human brain. MT ratio (MTR) was measured between single-SE and MESE protocols under different scan settings including varying echo train lengths, number of slices, and inter-slice gap. MTR and T-2 values were extracted for each model and protocol. Results: MT interactions biased MESE signals, and in certain settings, the corresponding T-2 values. T-2 underestimation of up to 4.3% was found versus single-SE values in vitro and up to 13.8% ex vivo, correlating with the MMP content. T-2 bias originated from intra-slice saturation of the MMP, rather than from indirect saturation in multi-slice acquisitions. MT-related signal attenuation was caused by slice crosstalk and/or partial T-1 recovery, whereas smaller contribution was caused by MMP interactions. Inter-slice gap had a similar effect on in vivo MTR (21.2%), in comparison to increasing the number of slices (18.9%). Conclusions: MT influences MESE protocols either by uniformly attenuating the entire echo train or by cumulatively attenuating the signal along the train. Although both processes depend on scan settings and MMP content, only the latter will cause underestimation of T-2.
引用
收藏
页码:145 / 158
页数:14
相关论文
共 63 条
[1]  
Ben-Eliezer N, 2016, P 24 ANN M ISMRM SIN
[2]   Accelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction [J].
Ben-Eliezer, Noam ;
Sodickson, Daniel K. ;
Shepherd, Timothy ;
Wiggins, Graham C. ;
Block, Kai Tobias .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) :1346-1354
[3]   Rapid and Accurate T2 Mapping from Multi-Spin-Echo Data Using Bloch-Simulation-Based Reconstruction [J].
Ben-Eliezer, Noam ;
Sodickson, Daniel K. ;
Block, Kai Tobias .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) :809-817
[4]   Synthetic MRI of the brain in a clinical setting [J].
Blystad, I. ;
Warntjes, J. B. M. ;
Smedby, O. ;
Landtblom, A-M ;
Lundberg, P. ;
Larsson, E-M .
ACTA RADIOLOGICA, 2012, 53 (10) :1158-1163
[5]  
Bottomley PA, 1984, BOTTOMLEY PA, Patent No. 4(480):228
[6]  
Cohen J., 2013, STAT POWER ANAL BEHA, V2nd, P567
[7]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[8]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[9]  
Dagher AP, 2000, J MAGN RESON IMAGING, V12, P745, DOI 10.1002/1522-2586(200011)12:5<745::AID-JMRI12>3.0.CO
[10]  
2-H