Controlling the Thermal Power of a Wall Heating Panel with Heat Pipes by Changing the Mass Flowrate and Temperature of Supplying Water-Experimental Investigations

被引:9
作者
Amanowicz, Lukasz [1 ]
机构
[1] Poznan Univ Tech, Inst Environm Engn & Bldg Serv, PL-60965 Poznan, Poland
关键词
wall-type heating system; heat pipes; thermal characteristics; thermal performance control; low-temperature heating; surface heating; radiant heating; low energy buildings; nearly zero energy building (nZEB); RESIDENTIAL BUILDINGS; TRANSFER COEFFICIENTS; ENERGY SAVINGS; PERFORMANCE; SYSTEM; EXCHANGER; ENHANCEMENT; RECOVERY;
D O I
10.3390/en13246547
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Renewable energy sources for the purpose of heating buildings cooperate perfectly with so-called low-temperature heating systems. Water loop surface heating systems had been thoroughly tested. In contrast, thermal performance of wall panels with heat pipes have not been fully recognized, yet. The determination of the thermal power as well as the control of panels thermal performance cannot be performed with the methods developed for water loop systems. In this paper, the novel heating panels with heat pipes were tested to analyze the possibility of controlling their performance by changing the mass flowrate of heating water and its temperature. Specific heating power of the investigated panels varies from 16.9 W/m(2) to 93.8 W/m(2) when supplying a water temperature ranging from 35 degrees C to 65 degrees C and mass flowrate from 10 g/s to 47.5 g/s. Investigations revealed that the thermal performance of the panels is more sensitive to the changes of temperature than to the changes of mass flowrate of supplying water, and thus, should be controlled by changing the supply water temperature at low mass flowrates to obtain a low energy usage of pumps (diminished pressure losses) and good quality of controlling.
引用
收藏
页数:18
相关论文
共 44 条
[1]   Experimental and theoretical investigation on a radiative flat heat pipe heat exchanger [J].
Almahmoud, Sulaiman ;
Jouhara, Hussam .
ENERGY, 2019, 174 :972-984
[2]   Influence of geometrical parameters on the flow characteristics of multi-pipe earth-to-air heat exchangers -experimental and CFD investigations [J].
Amanowicz, Lukasz .
APPLIED ENERGY, 2018, 226 :849-861
[3]   Validation of CFD model for simulation of multi-pipe earth-to-air heat exchangers (EAHEs) flow performance [J].
Amanowicz, Lukasz ;
Wojtkowiak, Janusz .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 :44-49
[4]   The Green Structure for Outdoor Places in Dry, Hot Regions and Seasons-Providing Human Thermal Comfort in Sustainable Cities [J].
Bandurski, Karol ;
Bandurska, Hanna ;
Kazimierczak-Grygiel, Ewa ;
Koczyk, Halina .
ENERGIES, 2020, 13 (11)
[5]   Assessment of thermo modernization using the global cost method [J].
Basinska, Malgorzata ;
Koczyk, Halina ;
Kosmowski, Andrzej .
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 :2040-2045
[6]   Sensitivity analysis in determining the optimum energy for residential buildings in Polish conditions [J].
Basinska, Malgorzata ;
Koczyk, Halina ;
Szczechowiak, Edward .
ENERGY AND BUILDINGS, 2015, 107 :307-318
[7]   An experimental study and computational validation of waste heat recovery from a lab scale ceramic kiln using a vertical multi-pass heat pipe heat exchanger [J].
Brough, Daniel ;
Mezquita, Ana ;
Ferrer, Salvador ;
Segarra, Carmen ;
Chauhan, Amisha ;
Almahmoud, Sulaiman ;
Khordehgah, Navid ;
Ahmad, Lujean ;
Middleton, David ;
Sewell, H. Isaac ;
Jouhara, Hussam .
ENERGY, 2020, 208
[8]   Experimental and numerical study on the application of low-temperature radiant floor heating system with capillary tube: Thermal performance analysis [J].
Cho, Jinkyun ;
Park, Beungyong ;
Lim, Taesub .
APPLIED THERMAL ENGINEERING, 2019, 163
[9]   On the influence of local and zonal hydraulic balancing of heating system on energy savings in existing buildings - Long term experimental research [J].
Cholewa, Tomasz ;
Balen, Igor ;
Siuta-Olcha, Alicja .
ENERGY AND BUILDINGS, 2018, 179 :156-164
[10]   Actual energy savings from the use of thermostatic radiator valves in residential buildings - Long term field evaluation [J].
Cholewa, Tomasz ;
Siuta-Olcha, Alicja ;
Balaras, Constantinos A. .
ENERGY AND BUILDINGS, 2017, 151 :487-493