DESIGN AND EVALUATION OF UPPER-ARM MOUSE USING INERTIAL SENSOR FOR HUMAN-COMPUTER INTERACTION

被引:0
|
作者
Widodo, Romy Budhi [1 ]
Haryasena, Agustinus Bohaswara [1 ]
Setiawan, Hendry [1 ]
Irawan, Paulus Lucky Tirma [1 ]
Subianto, Mochamad [1 ]
Wada, Chikamune [2 ]
机构
[1] Univ Ma Chung, Informat Engn, Ma Chung Human Machine Interact Res Ctr, Jalan Villa Puncak Tidar N-1, Malang 65151, Indonesia
[2] Kyushu Inst Technol, Grad Sch Life Sci & Syst Engn, Fukuoka 8080196, Japan
来源
JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY | 2020年 / 15卷 / 06期
关键词
Bend sensor; Electromyograph; Upper-arm mouse; IMU; ISO/TS; 9241-411;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pointing devices commonly used today, including the modern computer mouse, can only be operated manually. For people with physical impairments, usage can be problematic due to a limited ability to operate such devices. Therefore, this study was inspired to conduct research on designing and evaluating an appropriate mouse-substitution system for individuals who are physically impaired. The design of the system uses an inertial measurement unit (IMU) that is a fusion of a gyroscope and an accelerometer sensor in which the sensor is attached to a user's upper arm to recognise physical gestures. Any gestures performed by the upper arm are then mapped and used to manipulate mouse cursor movements on computer devices. The design of the "clicking" method uses both an electromyograph (EMG) sensor and a bend sensor. This study evaluates two input devices; one is a combination of an IMU and an EMG sensor, and the other is an input device that is a combination of an IMU and a bend sensor. Fitts' Law formula and the ISO/TS 9241-411: Ergonomics of human-system interaction standard were used to evaluate quantitative performance and level of comfort. The quantitative results show that the average throughput (TP) of the first input device (2.30 bps) differs greatly, statistically, in comparison to the second input device (1.75 bps). Similarly, the average movement time (tm) revealed that there is a statistically significant difference between the first input device (1.98 s) and the second input device (2.67 s). The qualitative results show that the comfort levels of the first input device are superior to those of the second input device. It concludes that the combination of IMU and EMG as a pointing and clicking apparatus revealed better performance than the combination of IMU and bend sensor.
引用
收藏
页码:3673 / 3690
页数:18
相关论文
共 50 条
  • [1] Human-Computer Interaction: Process and Principles of Human-Computer Interface Design
    Chao, Gong
    2009 INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING, PROCEEDINGS, 2009, : 230 - 233
  • [2] Interaction design: Beyond human-computer interaction
    Hansen, Heidi
    TECHNICAL COMMUNICATION, 2008, 55 (03) : 289 - 290
  • [3] Design and Evaluation of Human-Computer Rhythmic Interaction in a Tutoring System
    Jylha, Antti
    Ekman, Inger
    Erkut, Cumhur
    Tahiroglu, Koray
    COMPUTER MUSIC JOURNAL, 2011, 35 (02) : 36 - 48
  • [4] Design of a Capacitive Tactile Sensor Array System for Human-Computer Interaction
    Fei, Fei
    Jia, Zhenkun
    Wu, Changcheng
    Lu, Xiong
    Li, Zhi
    SENSORS, 2024, 24 (20)
  • [5] Human-Computer Interaction Design in Product Design
    Yang, XianYi
    Chen, Guo
    PROCEEDINGS OF THE FIRST INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND COMPUTER SCIENCE, VOL II, 2009, : 437 - 439
  • [6] On Study of Human-Computer Interaction Design
    Wang PeiHuan
    Yang XianYi
    Chen Guo
    PROCEEDINGS OF THE 9TH CONFERENCE ON MAN-MACHINE-ENVIRONMENT SYSTEM ENGINEERING, 2009, : 145 - 148
  • [7] Human-computer interaction A robotic arm actuated by the thought
    Guiguen, Anthony
    BIOFUTUR, 2012, (334) : 17 - 17
  • [8] Design and Evaluation of a Personalized Cancer Treatment System using Human-Computer Interaction Techniques
    Martinez, Alexandra
    Mora, Rodrigo
    Lopez, Gustavo
    Bolanos, Constantino
    Alvarado, Daniel
    Solano, Andres
    Lopez, Mariana
    Quiros, Steve
    Baez, Andres
    NEW ADVANCES IN INFORMATION SYSTEMS AND TECHNOLOGIES, VOL 1, 2016, 444 : 717 - 727
  • [9] Human-Computer Interaction: The Usability Test Methods and Design Principles in the Human-Computer Interface Design
    Gong Chao
    2009 2ND IEEE INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND INFORMATION TECHNOLOGY, VOL 3, 2009, : 283 - 285
  • [10] Inertial sensors and muscle electrical signals in human-computer interaction
    Ancans, Armands
    Rozentals, Artis
    Nesenbergs, Krisjanis
    Greitans, Modris
    2017 6TH INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY AND ACCESSIBILITY (ICTA), 2017,