Sequential injection redox or acid-base titration for determination of ascorbic acid or acetic acid

被引:54
作者
Lenghor, N
Jakmunee, J [1 ]
Vilen, M
Sara, R
Christian, GD
Grudpan, K
机构
[1] Chiang Mai Univ, Inst Sci & Technol Res & Dev, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
[2] Abo Akad Univ, Turku Ctr Biotechnol, FIN-20521 Turku, Finland
[3] Turku Univ, FIN-20521 Turku, Finland
[4] Univ Washington, Ctr Proc Analyt Chem, Dept Chem, Seattle, WA 98195 USA
关键词
sequential injection; titration; spectrophotometry; ascorbic acid; acetic acid;
D O I
10.1016/S0039-9140(02)00444-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l(-1) was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l(-1) ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid-base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2-8% w v(-1) of acetic acid with a relative standard deviation of 4.8% (5.0% w v(-1) acetic acid, n = 11) was obtained. Sample throughputs of 60 h(-1) were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1139 / 1144
页数:6
相关论文
共 10 条
[1]   Two-parameter determination in vinegar by a flow injection-pervaporation system [J].
González-Rodríguez, J ;
Pérez-Juan, P ;
de Castro, MDL .
ANALYST, 2001, 126 (07) :1177-1181
[2]   Flow injection spectrophotometric or conductometric determination of ascorbic acid in a vitamin C tablet using permanganate or ammonia [J].
Grudpan, K ;
Kamfoo, K ;
Jakmunee, J .
TALANTA, 1999, 49 (05) :1023-1026
[3]  
Grudpan K, 2000, LAB ROBOTICS AUTOMAT, V12, P129, DOI 10.1002/1098-2728(2000)12:3<129::AID-LRA2>3.0.CO
[4]  
2-P
[5]   A monosegmented flow titration for the spectrophotometric determination of total acidity in vinegar [J].
Honorato, RS ;
Araújo, MCU ;
Veras, G ;
Zagatto, EAG ;
Lapa, RAS ;
Lima, JLFC .
ANALYTICAL SCIENCES, 1999, 15 (07) :665-668
[6]   Titration of strong and weak acids by sequential injection analysis technique [J].
Maskula, S ;
Nyman, J ;
Ivaska, A .
TALANTA, 2000, 52 (01) :91-99
[7]   SEQUENTIAL INJECTION - A NEW CONCEPT FOR CHEMICAL SENSORS, PROCESS ANALYSIS AND LABORATORY ASSAYS [J].
RUZICKA, J ;
MARSHALL, GD .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :329-343
[8]   Sequential injection technique for automated titration: Spectrophotometric assay of vitamin C in pharmaceutical products using cerium(IV) in sulfuric acid [J].
Sultan, SM ;
Hassan, YAM ;
Ibrahim, KEE .
ANALYST, 1999, 124 (06) :917-921
[9]   Flow injection determination methods of ascorbic acid [J].
Yebra-Biurrun, MC .
TALANTA, 2000, 52 (03) :367-383
[10]  
[No title captured]