Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation

被引:40
|
作者
Liu, Jiying [1 ,2 ]
Dalgo, Daniel Alejandro [2 ]
Zhu, Shengwei [1 ]
Li, Hui [3 ]
Zhang, Linhua [3 ]
Srebric, Jelena [2 ]
机构
[1] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Shandong, Peoples R China
[2] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[3] Shandong Jianzhu Univ, Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
computational fluid dynamics (CFD); ductless personalized ventilation (DPV); displacement ventilation (DV); radiant floor cooling system (RFCS); INDOOR THERMAL COMFORT; AIR-CONDITIONING SYSTEM; ENERGY PERFORMANCE; CFD; CONJUNCTION; ROOMS; TEMPERATURE; EFFICIENCY; QUALITY; SAVINGS;
D O I
10.1007/s12273-019-0521-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study conducted the numerical simulation to evaluate the performance of a ductless personalized ventilation (DPV) combined with radiant floor cooling system (RFCS) and displacement ventilation (DV) system. In the non-DPV cases, DV supplies air at temperature of 16 degrees C and 20 degrees C, respectively with a flow rate of 2.4 ACH. In the cases with DPV, DPV supplies personalized air, which is drawn at the height of 0.1 m or 0.2 m above the floor, to the face of a seated occupant at flow rates of 3 L/s, 5 L/s and 7 L/s, respectively. The horizontal distance of 0.3 m is designed between DPV air supply opening and occupant face at the height of 1.2m. For all the cases, the floor cooling temperature is set to 20 degrees C. The vertical air temperature difference at 1.1 m and 0.1 m (Delta T1.1-0.1), the contaminant removal effectiveness (epsilon) and the draft rate at the occupant face (DRface) are mainly used as evaluation indices to quantify the ventilation effectiveness and thermal comfort effect. According to the results, DPV remarkably decreases Delta T1.1-0.1 with a maximum reduction of 1.79 degrees C compared to non-DPV case. DPV significantly influences the temperature adjacent to the face at the breathing zone, with a maximum reduction of 4.44 degrees C from non-DPV case to DPV case. DPV cases also effectively improve epsilon at breathing region compared to the non-DPV case. The DRface ranges from 9.01% to 21.33% when different flow rates of DPV are used. In summary, the case using DPV flow rate of 5 L/s and at intake height of 0.1 m presented relatively better ventilation effectiveness and thermal comfort environment around the occupant.
引用
收藏
页码:905 / 919
页数:15
相关论文
共 50 条
  • [1] Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation
    Jiying Liu
    Daniel Alejandro Dalgo
    Shengwei Zhu
    Hui Li
    Linhua Zhang
    Jelena Srebric
    Building Simulation, 2019, 12 : 905 - 919
  • [2] Analysis of feasibility of floor radiant cooling system combined with displacement ventilation
    Li, DY
    Ren, YL
    Wang, ZJ
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 634 - 637
  • [3] Performance evaluation of ductless personalized ventilation combined with impinging jet ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Wang, Faming
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [4] Performance of "ductless" personalized ventilation in conjunction with displacement ventilation: Impact of intake height
    Halvonova, Barbora
    Melikov, Arsen K.
    BUILDING AND ENVIRONMENT, 2010, 45 (04) : 996 - 1005
  • [5] Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System
    Xia, Xue-ying
    Zhang, Xu
    LOW-CARBON CITY AND NEW-TYPE URBANIZATION, 2015, : 307 - 315
  • [6] Performance of Ductless Personalized Ventilation in Conjunction with Displacement Ventilation: Impact of Workstations Layout and Partitions
    Halvonova, Barbora
    Melikov, Arsen K.
    HVAC&R RESEARCH, 2010, 16 (01): : 75 - 94
  • [7] Performance of ductless personalized ventilation in conjunction with displacement ventilation: Physical environment and human response
    Dalewski, Mariusz
    Melikov, Arsen K.
    Vesely, Michal
    BUILDING AND ENVIRONMENT, 2014, 81 : 354 - 364
  • [8] Thermal comfort and ventilation effectiveness in an office room with radiant floor cooling and displacement ventilation
    Krajcik, Michal
    Tomasi, Roberta
    Simone, Angela
    Olesen, Bjarne W.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (03) : 317 - 327
  • [9] The Comparison and Analysis of Humidity Environment between Floor and Ceiling Radiant Cooling Systems that Combined with Displacement Ventilation
    Sun, Kai
    Zhou, Chuan-hui
    PROCEEDINGS OF THE 2015 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS, 2015, 40 : 184 - 189
  • [10] Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation
    Song, Doosam
    Kim, Taeyeon
    Song, Suwon
    Hwang, Suckho
    Leigh, Seung-Bok
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1299 - 1311