Ablation of pulmonary vein foci for the treatment of atrial fibrillation - Percutaneous electroanatomical guided approach

被引:5
|
作者
Adragao, P [1 ]
Cavaco, D [1 ]
Aguiar, C [1 ]
Palos, J [1 ]
Morgado, F [1 ]
Ribeiras, R [1 ]
Abecasis, M [1 ]
Neves, J [1 ]
Bonhorst, D [1 ]
Seabra-Gomes, R [1 ]
机构
[1] Hosp Santa Cruz, Dept Cardiol, P-2795 Carnaxide, Portugal
来源
EUROPACE | 2002年 / 4卷 / 04期
关键词
atrial fibrillation; catheter ablation; electroanatomic mapping; electrophysiology;
D O I
10.1053/eupc.2002.0257
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the usefulness of three-dimensional (3D) electroanatomical mapping of the pulmonary veins (PV) for guiding radiofrequency (RF) ablation of focal atrial fibrillation (AF) in a single session and to correlate the electrophysiological results with the six month clinical outcome. Methods and Results Sixteen consecutive patients with idiopathic paroxysmal AF (more than 1 episode/month) were studied. A non-fluoroscopic mapping system was used to generate 3D electroanatomic maps of the left atrium and deliver RF energy. In patients with frequent ectopies, mapping was performed using the 'hot-cold' approach (looking for the earliest electrogram in the 3D reconstruction). In patients with infrequent/no ectopies, double/ multiple potentials recorded at the PV were tagged. Pacing at these sites to test for inducibility of ectopy or atrial fibrillation was used to define PV foci. The therapeutic endpoint was defined as suppression of premature beats, dissociation of PV potentials and inability to induce AF. Twenty-five foci were identified (multiple foci in 38%). In the 4 pts with frequent ectopies, Group A, these were suppressed by 4 +/- 4.7 applications. In the 12 wpts with infrequent/no ectopies, Group B, an average 4.7 +/- 1.8 applications were delivered per focus; the endpoint was achieved in eight of the patients (13 of 21 foci). By 180 days follow-up, 11 patients were free of symptoms and in sinus rhythm, two had paroxysmal AF episodes and 3 have symptomatic ectopies and are receiving antiarrhythmic drugs. The overall success rate at six months was thus 69%, 100% for group A and 58% for group B. Conclusion Electroanatomic guided RF ablation of paroxysmal AF was highly successful in patients with frequent ectopies. The use of electroanatomical mapping for precise anatomical localization of multiple potentials and for guiding the PV ostia isolation allowed successful RF ablation in 50% of pts with infrequent/no ectopies. (C) 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 50 条
  • [41] Safety and efficacy of circumferential pulmonary vein catheter ablation of atrial fibrillation
    Vasamreddy, CR
    Dalal, D
    Eldadah, Z
    Dickfeld, T
    Jayam, VK
    Henrickson, C
    Meininger, G
    Dong, J
    Lickfett, L
    Berger, R
    Calkins, H
    HEART RHYTHM, 2005, 2 (01) : 42 - 48
  • [42] Pulmonary vein activity: a step towards personalizing atrial fibrillation ablation
    Del Monte, Alvise
    Baykaner, Tina
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (04) : 691 - 692
  • [43] The Anatomical Basis of Pulmonary Vein Reconnection After Ablation for Atrial Fibrillation
    McGarry, Thomas J.
    Narayan, Sanjiv M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (10) : 939 - 941
  • [44] Pulmonary vein stenosis complicating catheter ablation of focal atrial fibrillation
    Scanavacca, MI
    Kajita, LJ
    Vieira, M
    Sosa, EA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (06) : 677 - 681
  • [45] Efficacy of circumferential pulmonary vein ablation of atrial fibrillation in endurance athletes
    Calvo, Naiara
    Mont, Lluis
    Tamborero, David
    Berruezo, Antonio
    Viola, Graziana
    Guasch, Eduard
    Nadal, Merce
    Andreu, David
    Vidal, Barbara
    Sitges, Marta
    Brugada, Josep
    EUROPACE, 2010, 12 (01): : 30 - 36
  • [46] Pulmonary Vein Stenosis: A Complication of Atrial Fibrillation Ablation Treated with Stenting
    Mishra, Akshay
    Deen, Vince
    Slaughter, Richard
    Walters, Darren L.
    HEART LUNG AND CIRCULATION, 2010, 19 (02) : 97 - 99
  • [47] Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Garrigue, S
    Takahashi, A
    Lavergne, T
    Hocini, M
    Peng, JT
    Roudaut, R
    Clementy, J
    CIRCULATION, 2000, 101 (12) : 1409 - 1417
  • [48] Substrate Ablation Without Pulmonary Vein Isolation A Reasonable Proposition for Atrial Fibrillation Ablation?
    Hummel, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (03) : 322 - 324
  • [49] Cost effectiveness of focal impulse and rotor modulation guided ablation added to pulmonary vein isolation for atrial fibrillation
    Baykaner, Tina
    Duff, Steve
    Hasegawa, James T.
    Mafilios, Michael S.
    Turakhia, Mintu P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (04) : 526 - 536
  • [50] Pulmonary vein signal interpretation during cryoballoon ablation for atrial fibrillation
    Andrade, Jason G.
    Dubuc, Marc
    Collet, Daina
    Khairy, Paul
    Macle, Laurent
    HEART RHYTHM, 2015, 12 (06) : 1387 - 1394