A novel and sensitive method for ethinylestradiol quantification in human plasma by high-performance liquid chromatography coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometry: Application to a comparative pharmacokinetics study

被引:15
作者
Borges, Ney Carter [1 ,2 ]
Astigarraga, Rafael Barrientos [4 ]
Sverdloff, Carlos Eduardo [1 ,3 ]
Galvinas, Paulo Rabelo [4 ]
da Silva, Washington Moreira [4 ]
Rezende, Vinicius Marcondes [1 ]
Moreno, Ronilson Agnaldo [1 ,3 ]
机构
[1] Synchrophar Assessoria & Desenvolvimento Projetos, BR-13015025 Campinas, SP, Brazil
[2] Univ Estadual Campinas, Fac Med Sci, Dept Internal Med, BR-13083970 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Fac Med Sci, Dept Pharmacol, BR-13083970 Campinas, SP, Brazil
[4] Magabi Pesquisas Clin & Farmaceut, BR-04795100 Jurubatuba, SP, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 29期
关键词
Ethinylestradiol; Bioequivalence; Plasma; Pharmacokinetics; APPI; Mass spectrometry; ETHINYL ESTRADIOL; ELECTROSPRAY-IONIZATION; URINARY METABOLITES; CHEMICAL-IONIZATION; CYPROTERONE-ACETATE; ESTROGENIC STEROIDS; WASTE-WATER; ETHYNYLESTRADIOL; NORETHINDRONE; WOMEN;
D O I
10.1016/j.jchromb.2009.08.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present Study, a novel, fast, sensitive and robust method to quantify ethinylestradiol in human plasma using 17 alpha-ethinylestradiol-d4 as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction (LLE) using diethyl ether-hexane followed by online solid phase extraction (SPE) using online C18 cartridges. Extracted samples were analyzed by high-performance liquid chromatography coupled to atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 mu m analytical column. The method had a chromatographic run time of 2.50 min and a linear calibration Curve over the range 5-500 pg ml(-1) (r(2) > 0.9992). The lowest concentration quantified was 5 pg ml(-1), demonstrating acceptable accuracy and precision. The intra-assay precisions ranged from 2.1 to 14.6%. while inter-assay precisions ranged from 4.4 to 11.4%. The intra-assay accuracies ranged from 94.6 to 103.8%, while the inter-assay accuracies ranged from 98.9 to 101.6%. The recovery of ethinylestradiol was determined as part of the assay validation process and was 73.1 and 79.0% for the concentrations 15 and 375 pg ml(-1). respectively. Short-term stability showed that ethinylestradiol was stable in plasma for at least 19 h at room temperature or for at least 385 days when stored at -20 degrees C. In the study of bioequivalence conducted in Brazil, healthy Volunteers received two ethinylestradiol 0.035 mg tablet formulations using an open, randomized, two-period crossover design with a 2-week washout interval. Since the 90% confidence interval for C-max and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the two ethinylestradiol formulations are bioequivalent with respect to both the rate and the extent of absorption. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3601 / 3609
页数:9
相关论文
共 33 条
[1]   INVESTIGATION OF THE PHARMACOKINETICS OF ETHYNYLESTRADIOL IN WOMEN USING RADIOIMMUNOASSAY [J].
BACK, DJ ;
BRECKENRIDGE, AM ;
CRAWFORD, FE ;
MACIVER, M ;
ORME, MLE ;
ROWE, PH ;
WATTS, MJ .
CONTRACEPTION, 1979, 20 (03) :263-273
[2]   THE GUT WALL METABOLISM OF ETHINYLESTRADIOL AND ITS CONTRIBUTION TO THE PRE-SYSTEMIC METABOLISM OF ETHINYLESTRADIOL IN HUMANS [J].
BACK, DJ ;
BRECKENRIDGE, AM ;
MACIVER, M ;
ORME, M ;
PURBA, HS ;
ROWE, PH ;
TAYLOR, I .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 13 (03) :325-330
[3]   The effect of food on the bioavailability of norethindrone and ethinyl estradiol from norethindrone acetate/ethinyl estradiol tablets intended for continuous hormone replacement therapy [J].
Boyd, RA ;
Zegarac, EA ;
Eldon, MA .
JOURNAL OF CLINICAL PHARMACOLOGY, 2003, 43 (01) :52-58
[4]   Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discovery [J].
Cai, YX ;
Kingery, D ;
McConnell, O ;
Bach, AC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (12) :1717-1724
[5]   Determination of estrogenic compounds in wastewater using liquid chromatography-tandem mass spectrometry with electrospray and atmospheric pressure photoionization following desalting extraction [J].
Chen, Hsin-Chang ;
Kuo, Han-Wen ;
Ding, Wang-Hsien .
CHEMOSPHERE, 2009, 74 (04) :508-514
[6]   Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up [J].
Christiaens, B ;
Fillet, A ;
Chiap, P ;
Rbeida, O ;
Ceccato, A ;
Streel, B ;
De Graeve, J ;
Crommen, J ;
Hubert, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) :105-110
[7]   Determination of estrogens and progestogens by mass spectrometric techniques (GC/MS, LC/MS and LC/MS/MS) [J].
Díaz-Cruz, MS ;
de Alda, MJL ;
López, R ;
Barceló, D .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (09) :917-923
[8]   Measurement of endogenous estrogens: analytical challenges and recent advances [J].
Giese, RW .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :401-412
[9]  
GUENGERICH FP, 1990, LIFE SCI, V47, P1981
[10]  
INNHOFFEN HH, 1938, NATURWISSENSCHAFTEN, V26, P96