Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

被引:1
作者
Farina, Edoardo [1 ,2 ]
Piersimoni, Pierluigi [3 ]
Riccardi, Cristina [1 ,2 ]
Rimoldi, Adele [1 ,2 ]
Tamborini, Aurora [1 ,2 ]
Ciocca, Mario [4 ]
机构
[1] Univ Pavia, Via Bassi 6, I-27100 Pavia, Italy
[2] INFN Sect Pavia, I-27100 Pavia, Italy
[3] Loma Linda Univ, Div Radiat Res, Loma Linda, CA 92354 USA
[4] CNAO Fdn, Med Phys Unit, I-27100 Pavia, Italy
来源
2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA) | 2015年
关键词
Geant4; simulation; Ocular melanoma; Beam active scanning technique; RADIOTHERAPY;
D O I
10.1109/ANIMMA.2015.7465562
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eve-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons.
引用
收藏
页数:6
相关论文
共 12 条
  • [1] Radiotherapy with beams of carbon ions
    Amaldi, U
    Kraft, G
    [J]. REPORTS ON PROGRESS IN PHYSICS, 2005, 68 (08) : 1861 - 1882
  • [2] Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification
    Borca, Valeria Casanova
    Pasquino, Massimo
    Russo, Giuliana
    Grosso, Pierangelo
    Cante, Domenico
    Sciacero, Piera
    Girelli, Giuseppe
    La Porta, Maria Rosa
    Tofani, Santi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 158 - 171
  • [3] Monte Carlo simulations of ripple filters designed for proton and carbon ion beams in hadrontherapy with actives canning technique
    Bourhaleb, F.
    Attili, A.
    Cirio, R.
    Cirrone, P.
    Marchetto, F.
    Donetti, M.
    Garella, M. A.
    Giordanengo, S.
    Givehchi, N.
    Iliescu, S.
    La Rosa, A.
    Pardo, J.
    Pecka, A.
    Peroni, C.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [4] A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN
    Cirrone, GAP
    Cuttone, G
    Lojacono, PA
    Lo Nigro, S
    Mongelli, V
    Patti, IV
    Privitera, G
    Raffaele, L
    Rifuggiato, D
    Sabini, MG
    Salamone, V
    Spatola, C
    Valastro, LM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 860 - 865
  • [5] The CNAO dose delivery system for modulated scanning ion beam radiotherapy
    Giordanengo, S.
    Garella, M. A.
    Marchetto, F.
    Bourhaleb, F.
    Ciocca, M.
    Mirandola, A.
    Monaco, V.
    Hosseini, M. A.
    Peroni, C.
    Sacchi, R.
    Cirio, R.
    Donetti, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 263 - 275
  • [6] Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties
    Molinelli, S.
    Mairani, A.
    Mirandola, A.
    Freixas, G. Vilches
    Tessonnier, T.
    Giordanengo, S.
    Parodi, K.
    Ciocca, M.
    Orecchia, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (11) : 3837 - 3847
  • [7] Optimization of a general-purpose, actively scanned proton beamline for ocular treatments: Geant4 simulations
    Piersimoni, Pierluigi
    Rimoldi, Adele
    Riccardi, Cristina
    Pirola, Michele
    Molinelli, Silvia
    Ciocca, Mario
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 261 - 278
  • [8] Geant4 studies of the CNAO facility system for hadrontherapy treatment of uveal melanomas
    Rimoldi, A.
    Piersimoni, P.
    Pirola, M.
    Riccardi, C.
    [J]. 20TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2013), PARTS 1-6, 2014, 513
  • [9] Rimoldi A, 2013, IEEE NUCL SCI CONF R
  • [10] The National Centre for Oncological Hadrontherapy (CNAO): Status and perspectives
    Rossi, Sandro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (04): : 333 - 351