Direct monitoring of ochratoxin A in cheese with solid-phase microextraction coupled to liquid chromatography-tandem mass spectrometry

被引:45
|
作者
Zhang, Xu [1 ]
Cudjoe, Erasmus [1 ]
Vuckovic, Dajana [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
Ochratoxin A; SPME; In situ sampling; Cheese; Mycotoxin; CYCLOPIAZONIC ACID; WINE; CALIBRATION; STANDARDS; CLEANUP; FOODS;
D O I
10.1016/j.chroma.2009.03.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An in situ application of solid-phase microextraction (SPME) as a sampling and sample preparation method coupled to HPLC-MS/MS for direct monitoring of ochratoxin A (OTA) distribution at different locations in a single cheese piece is proposed to be suited to the acidic analyte the extraction phase (carbon-tape SPME fiber) was acidified With aqueous solution Of HCl at pH 2. instead of the traditional sample pre-treatment with acids before SPME sampling For calibration, kinetic on-fiber-standardization Was used. which allowed the use of short sampling time (20 min) and accurate (quantification of the OTA in the semi-solid cheese sample. In addition. the traditional kinetic calibration that Used deuterated compounds as standards was extended to we a non-deuterated analogue ochraroxin B (OTB) as the standard of the analyte OTA, which Was supported by both theoretical discussion and experimental verification Finally. the minaturized SPMF fiber was adopted so that the concentration distribution of OTA in a small-sized cheese piece Could he directly probed The detection limit of the resulting SPME method in semi-solid gel was 15 ng/mL and the linear range was 35-500 ng/mL. The SPME-LC-MS/MS method showed good precision(RSI) similar to 10%) and accuracy (relative recovery. 93%) in the gel model. The direct cheese analysis showed comparable accuracy and precision to the established liquid extraction. As a result, the developed in mu SPME-LC-MS/MS method was sensitive. simple, accurate and applicable for the analysis of complicated lipid-rich samples such as cheese. (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:7505 / 7509
页数:5
相关论文
共 50 条
  • [41] Rapid Analysis of 27 Volatile Sulfur Compounds in Wine by Headspace Solid-Phase Microextraction Gas Chromatography Tandem Mass Spectrometry
    Slaghenaufi, Davide
    Tonidandel, Loris
    Moser, Sergio
    Villegas, Tomas Roman
    Larcher, Roberto
    FOOD ANALYTICAL METHODS, 2017, 10 (11) : 3706 - 3715
  • [42] Determination of phase-partitioning tracer candidates in production waters from oilfields based on solid-phase microextraction followed by gas chromatography-tandem mass spectrometry
    Silva, Mario
    Bjornstad, Tor
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1629
  • [44] Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples
    Carmen Salgado-Petinal
    Maria Garcia-Chao
    Maria Llompart
    Carmen Garcia-Jares
    Rafael Cela
    Analytical and Bioanalytical Chemistry, 2006, 385 : 637 - 644
  • [45] Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples
    Salgado-Petinal, Carmen
    Garcia-Chao, Maria
    Llompart, Maria
    Garcia-Jares, Carmen
    Cela, Rafael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) : 637 - 644
  • [46] Determination of ochratoxin A in beer by immunoaffinity cleanup and liquid chromatography with tandem mass spectrometry
    Omote, M.
    Kitagawa, Y.
    Mochizuki, N.
    JOURNAL OF THE AMERICAN SOCIETY OF BREWING CHEMISTS, 2008, 66 (02) : 59 - 62
  • [47] Disposable solid-phase microextraction fiber coupled with gas chromatography-mass spectrometry for complex matrix analysis
    Xu, Jianqiao
    He, Shuming
    Jiang, Ruifen
    Zhu, Fang
    Ruan, Jingwen
    Liu, Hong
    Luan, Tiangang
    Ouyang, Gangfeng
    ANALYTICAL METHODS, 2014, 6 (13) : 4895 - 4900
  • [48] On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples
    Chafer-Pericas, C.
    Herraez-Hernandez, R.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (02) : 159 - 171
  • [49] Study of kinetic desorption rate constant in fish muscle and agarose gel model using solid phase microextraction coupled with liquid chromatography with tandem mass spectrometry
    Togunde, Oluranti Paul
    Oakes, Ken
    Servos, Mark
    Pawliszyn, Janusz
    ANALYTICA CHIMICA ACTA, 2012, 742 : 2 - 9
  • [50] Simple approach for the determination of brominated flame retardants in environmental solid samples based on solvent extraction and solid-phase microextraction followed by gas chromatography-tandem mass spectrometry
    Salgado-Petinal, Carmen
    Llompart, Maria
    Garcia-Jares, Carmen
    Garcia-Chao, Maria
    Cela, Rafael
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) : 139 - 147