Inductance calibration in the frequency range from 50 Hz to 1 MHz at PTB

被引:9
|
作者
Hanke, R [1 ]
Kölling, A [1 ]
Melcher, J [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1109/CPEM.2002.1034782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inductance calibrations at PTB are carried out with a Maxwell-Wien bridge. This bridge has the advantage that the first order bridge equation (1) is independent of frequency which means that the bridge has the potential to be operated in a large frequency range. However, the actual frequency range, from power frequencies up to 1 MHz, requires an investigation of higher order effects.
引用
收藏
页码:186 / 187
页数:2
相关论文
共 50 条
  • [1] Dielectric properties of skeletal muscle during ischemia in the frequency range from 50 hz to 200 MHz
    Schäfer, M
    Kirlum, HJ
    Schlegel, C
    Gebhard, MM
    ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 59 - 64
  • [2] Bioimpedance spectroscopy for cell characterization in the 50Hz-5MHz frequency range
    Margo, Cedric
    Prado, Juan
    Kouider, Mourad
    Rouane, Amar
    Nadi, Mustapha
    PRIME 2006: 2ND CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONIC AND ELECTRONICS, PROCEEDINGS, 2006, : 441 - +
  • [3] Ohmic Heating of Peaches in the Wide Range of Frequencies (50 Hz to 1 MHz)
    Shynkaryk, Mykola V.
    Ji, Taehyun
    Alvarez, Valente B.
    Sastry, Sudhir K.
    JOURNAL OF FOOD SCIENCE, 2010, 75 (07) : E493 - E500
  • [4] Development and evaluation of primary calibration methods in underwater acoustics in a frequency range from 1 Hz to 100 Hz
    Biber, Alper
    Corakci, Ata C.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [5] Calibration of Ultrasonic Hydrophone Probes in the Frequency Range from 250 kHz to 1 MHz
    Umchid, Sumet
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [6] A calculable pistonphone for the absolute calibration of hydrophones in the frequency range from 0.5 Hz to 250 Hz
    Malcher, Freya
    Ford, Ben
    Barham, Richard
    Robinson, Stephen
    Ward, Jake
    Wang, Lian
    Bridges, Angus
    Yacoot, Andrew
    Cheong, Sei-Him
    Rodrigues, Dominique
    Barrera-Figueroa, Salvador
    METROLOGIA, 2024, 61 (02)
  • [7] NRC-PTB intercomparison of voltage transformer calibration systems for high voltage at 60 Hz, 50 Hz, and 16.66 Hz
    So, E
    Latzel, HG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 419 - 421
  • [8] COMPLEX BIOELECTRIC IMPEDANCE MEASUREMENT SYSTEM FOR THE FREQUENCY-RANGE FROM 5 HZ TO 1 MHZ
    ACKMANN, JJ
    ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (02) : 135 - 146
  • [10] Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz
    Umchid, S.
    Gopinath, R.
    Srinivasan, K.
    Lewin, P. A.
    Daryoush, A. S.
    Bansal, L.
    El-Sherif, M.
    ULTRASONICS, 2009, 49 (03) : 306 - 311