Shifting the paradigm in gas chromatography mass spectrometry pesticide analysis using high resolution accurate mass spectrometry

被引:31
作者
Ucles, S. [1 ]
Ucles, A. [1 ]
Lozano, A. [1 ]
Martinez Bueno, M. J. [1 ]
Fernandez-Alba, A. R. [1 ]
机构
[1] Univ Almeria, European Union Reference Lab Pesticide Residues F, Agrifood Campus Int Excellence ceiA3, Dept Chem & Phys, Almeria 04120, Spain
关键词
HRAMS; Q Exactive-Orbitrap; Pesticide residues; Gas chromatography; Sensitivity; PERFORMANCE LIQUID-CHROMATOGRAPHY; VEGETABLES; FRUITS; VALIDATION; MS;
D O I
10.1016/j.chroma.2017.04.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the last 10 years, the majority of the pesticide food control laboratories moved from GC MS to GC MS/MS as the preferred analytical technique to address GC amenable compounds. The main reason for this change was the negative impact on the single stage GC MS analysis caused by the interference from coeluting matrix compounds. The new development of gas chromatography coupled to high resolution accurate mass spectrometry (GC-HRAMS) provides opportunities to overcome such matrix interferences as a result of its much higher selectivity; allowing laboratories to carry out full-scan analysis covering the most exigent analytical performance criteria. The aim of this work is the evaluation of the main analytical performance parameters for the multiresidue screening of pesticide residues by a gas chromatography-Orbitrap (TM) mass spectrometer in fruits and vegetables. Electron ionization and full-scan high resolution mass spectrometry was selected for this evaluation. Mass resolving power, selectivity, sensitivity, analyte identification and database generation are discussed in light of the analysis of various commodities and a large scope of pesticides. The selected operational conditions provided optimal mass accuracy, within +/- 1 mDa and achieved LOQs of 10 mu g/kg or lower for practically all the selected pesticides and commodities. Applicability for quantitative residue analysis was verified by the validation of the 210 pesticides in four matrices (tomato, apple, leek and orange). The performance of the GC-El-full scan Orbitrap HRAMS developed method was confirmed with the analysis of 102 real samples providing good results. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 13 条
  • [1] Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables
    Cao Xinyue
    Pang Guofang
    Jin Linghe
    Kang Jian
    Hu Xueyan
    Chang Qiaoying
    Wang Minglin
    Fan Chunlin
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (04) : 389 - 396
  • [2] Reliability of veterinary drug residue confirmation: High resolution mass spectrometry versus tandem mass spectrometry
    Kaufmann, A.
    Butcher, P.
    Maden, K.
    Walker, S.
    Widmer, M.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 856 : 54 - 67
  • [3] Quantitative and confirmative performance of liquid chromatography coupled to high-resolution mass spectrometry compared to tandem mass spectrometry
    Kaufmann, Anton
    Butcher, Patrick
    Maden, Kathryn
    Walker, Stephan
    Widmer, Miryam
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (07) : 979 - 992
  • [4] Full Scan MS in Comprehensive Qualitative and Quantitative Residue Analysis in Food and Feed Matrices: How Much Resolving Power is Required?
    Kellmann, Markus
    Muenster, Helmut
    Zomer, Paul
    Mol, Hans
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) : 1464 - 1476
  • [5] Lee YJ, 2012, MASS SPECTROM LETT, V3, P29
  • [6] Official Journal of the European Union, 2007, OFFICIAL J EUROPEAN
  • [7] Rajski L, 2016, COMP ANAL C, V71, P119, DOI 10.1016/bs.coac.2016.02.001
  • [8] Large pesticide multiresidue screening method by liquid chromatography-Orbitrap mass spectrometry in full scan mode applied to fruit and vegetables
    Rajski, Lukasz
    del Mar Gomez-Ramos, Maria
    Fernandez-Alba, Amadeo R.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 : 119 - 127
  • [9] Validation of a multiclass multiresidue method and monitoring results for 210 pesticides in fruits and vegetables by gas chromatography-triple quadrupole mass spectrometry
    Ucles, Samanta
    Belmonte, Noelia
    Mezcua, Milagros
    Martinez, Ana B.
    Martinez-Bueno, M. Jesus
    Gamon, Miguel
    Fernandez-Alba, Amadeo R.
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2014, 49 (08) : 557 - 568
  • [10] Construction and application of a mass spectral and retention time index database generated from plant GC/EI-TOF-MS metabolite profiles
    Wagner, C
    Sefkow, M
    Kopka, J
    [J]. PHYTOCHEMISTRY, 2003, 62 (06) : 887 - 900