Development and Validation of RP-HPLC Method for the Simultaneous Determination of Levamisole HCl and Oxyclozanide and its Application in the Assay of Veterinary Bolus Formulations

被引:1
作者
Seid, Kemal Hussien [1 ,2 ]
Berhanu, Tarekegn [3 ,4 ]
Asres, Kaleab [1 ]
Ashenef, Ayenew [1 ]
机构
[1] Addis Ababa Univ, Coll Hlth Sci, Sch Pharm, Dept Pharmaceut Chem & Pharmacognosy, POB 1176, Addis Ababa, Ethiopia
[2] Ethiopian Food & Drug Author EFDA, Food Med & Hlth Care Adm & Control Author Ethiopi, Food & Drug Qual Control Lab, POB 5681, Addis Ababa, Ethiopia
[3] Fed Minist Agr, Pesticides Residue Anal Lab, Addis Ababa, Ethiopia
[4] Addis Ababa Sci & Technol Univ, Dept Ind Chem, POB 16417, Addis Ababa, Ethiopia
关键词
Analytical method development; bolus formulations; RP-HPLC; levamisole; oxyclozanide; ABSORPTION SPECTROMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHY; ULTRAVIOLET; TISSUES; MILK; HYDROCHLORIDE; PROPRANOLOL; RESIDUES; PINDOLOL; DRUG;
D O I
10.2174/1573412916666200211101633
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: A reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous analysis of two drugs, levamisole hydrochloride (LH) and oxyclozanide (OX), in co-formulation for veterinary use. Materials and Methods: The new HPLC method was validated as per the ICH and other guidelines. A C18 column was used with a gradient program; eluent A was an equal mixture of methanol and acetonitrile, and eluent B included a 25 mM phosphate buffer at pH 7.0 containing 30 mM sodium decanesulfonate and triethylamine (50:50:1 v/v) with pH adjusted to 7.0 using H3PO4 [51:49 v/v] .The detection wavelength was set at 220 nm. For the final gradient program, the retention times were 8.2(for LH) and 13.6(for OX) minutes, respectively, at a flow rate of 1 ml/min over 20 minutes run time. Results: The method was precise, specific and robust. The correlation coefficient, R-2 was 0.9998 and 0.9999 for LH and OX, respectively in the range of 5 - 280 mu g/mL. The percent y-intercepts and percent residual standard deviations were 1.6%/0.4% and 1.4%/1.0% for LH and OX, respectively. The LOD and LOQ of the method were 0.21 mu g/mL and 0.62 mu g/mL for LH and 0.06 mu g/mL and 0.18 mu g/mL for OX. The method has an average accuracy of 100.5% for LH and 101.1% for OX when tested on veterinary bolus formulations, and the samples could be stored under typical lab conditions for about 7 days without significant degradation. Conclusion: This HPLC method is suitable for assaying levamisole hydrochloride and oxyclozanide simultaneously from veterinary formulations.
引用
收藏
页码:654 / 664
页数:11
相关论文
共 50 条
  • [21] Development and Validation of New RP-HPLC Method for the Determination of Dexrazoxane
    Rao, M. V. Basaveswara
    Prasanthi, V.
    Rao, G. Venkata
    Raman, B. V.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 74 (06) : 588 - 591
  • [22] Development and Validation of RP-HPLC Method for Simultaneous Estimation of Glibenclamide and Thymoquinone in Rat Plasma and Its Application to Pharmacokinetics
    Ahmad, A.
    Khan, R. M. A.
    Alkharfy, K. M.
    ACTA CHROMATOGRAPHICA, 2015, 27 (03) : 435 - 448
  • [23] Simultaneous RP-HPLC determination of sparfloxacin and dexamethasone in pharmaceutical formulations
    Razzaq, Syed Naeem
    Ashfaq, Muhammad
    Mariam, Irfana
    Khan, Islam Ullah
    Razzaq, Syed Saleem
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 49 (02) : 301 - 309
  • [24] Development and application of stability indicating RP-HPLC method for the determination of Me Cobalamin in pharmaceutical formulations
    Ansari, Tariq Mahmood
    Raza, Asad
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (08) : 1221 - 1229
  • [25] Use of chemometrics for development and validation of an RP-HPLC method for simultaneous determination of haloperidol and related compounds
    Petkovska, Rumenka
    Dimitrovska, Aneta
    ACTA PHARMACEUTICA, 2008, 58 (03) : 243 - 256
  • [26] Development of RP-HPLC method for simultaneous determination of docetaxel and curcumin in rat plasma: Validation and stability
    Kim, Dong Wuk
    Yousaf, Abid Mehmood
    Li, Dong Xun
    Kim, Jong Oh
    Yong, Chul Soon
    Cho, Kwan Hyung
    Choi, Han-Gon
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 12 (01) : 105 - 113
  • [27] METHOD DEVELOPMENT AND VALIDATION OF SIMULTANEOUS DETERMINATION OF HYDROCHLOROTHIAZIDE AND LOSARTAN IN TABLET DOSAGE FORM BY RP-HPLC
    Mohammed, Nidhal M. Sher
    Abdo, Hasan R.
    Hassan, Hassan M.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2019, 10 (01): : 227 - 231
  • [28] RP-HPLC Method Development and Its Validation for Quantitative Determination of Rimonabant in Human Plasma
    Bankey, Shravan
    Tapadiya, Ganesh
    Lamale, Jasvant
    Jain, Deepti
    Saboo, Shweta
    Khadabadi, S. S.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2012, 2012
  • [29] RP-HPLC Method Development and Validation of Tapentadol Hydrochloride in Bulk and Pharmaceutical Formulations
    Sangeetha, G.
    Manickam, M. Swamivel
    Kumar, P. Sanil
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (11) : 7 - 16
  • [30] DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF TIZANIDINE HCL AND MELOXICAM IN BILAYER MUCOADHESIVE BUCCAL FILMS
    Zaman, Muhammad
    Hanif, Muhammad
    Amjad, Muhammad Wahab
    Murtaza, Hassan
    Raja, Maria Abdul Ghafoor
    Kashif, Muhammad
    ACTA POLONIAE PHARMACEUTICA, 2018, 75 (04): : 851 - 859