Diagnostic accuracy of low-dose and ultra-low-dose CT in detection of chest pathology: a systematic review

被引:40
|
作者
Taekker, Maria [1 ,2 ]
Kristjansdottir, Bjorg [1 ,2 ]
Graumann, Ole [1 ,2 ]
Laursen, Christian B. [3 ,4 ]
Pietersen, Pia, I [3 ,5 ]
机构
[1] Univ Southern Denmark, Res & Innovat Unit Radiol, Kloevervaenget 10,Entrance 112,2nd Floor, DK-5000 Odense C, Denmark
[2] Odense Univ Hosp, Dept Radiol, Kloevervaenget 47, DK-5000 Odense C, Denmark
[3] Odense Univ Hosp, Dept Resp Med, Kloevervaenget 2,Entrance 87-88, DK-5000 Odense C, Denmark
[4] Univ Southern Denmark, Fac Hlth Sci, Dept Clin Res, Campusvej 55, DK-5230 Odense, Denmark
[5] Odense Univ Hosp, Reg Ctr Tech Simulat, Reg Southern Denmark, JB Winslows Vej 4, DK-5000 Odense C, Denmark
关键词
Ultra-low-dose CT; Low-dose CT; Chest pathology; Diagnostic accuracy; Systematic review; NODULE DETECTION PERFORMANCE; COMPUTED-TOMOGRAPHY CT; ITERATIVE RECONSTRUCTION; LUNG-CANCER; PULMONARY NODULES; STANDARD; SIZE; CAPABILITY; AGREEMENT; REDUCTION;
D O I
10.1016/j.clinimag.2020.12.041
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Studies have evaluated imaging modalities with a lower radiation dose than standard-dose CT (SD-CT) for chest examination. This systematic review aimed to summarize evidence on diagnostic accuracy of these modalities ? low-dose and ultra-low-dose CT (LD- and ULD-CT) ? for chest pathology. Method: Ovid-MEDLINE, Ovid-EMBASE and the Cochrane Library were systematically searched April 29th?30th, 2019 and screened by two reviewers. Studies on diagnostic accuracy were included if they defined their index tests as ?LD-CT?, ?Reduced-dose CT? or ?ULD-CT? and had SD-CT as reference standard. Risk of bias was evaluated on study level using the Quality Assessment of Diagnostic Accuracy Studies-2. A narrative synthesis was conducted to compare the diagnostic accuracy measurements. Results: Of the 4257 studies identified, 18 were eligible for inclusion. SD-CT (3.17 ? 1.47 mSv) was used as reference standard in all studies to evaluate diagnostic accuracy of LD- (1.22 ? 0.34 mSv) and ULD-CT (0.22 ? 0.05 mSv), respectively. LD-CT had high sensitivities for detection of bronchiectasis (82?96%), honeycomb (75?100%), and varying sensitivities for nodules (63?99%) and ground glass opacities (GGO) (77?91%). ULD-CT had high sensitivities for GGO (93?100%), pneumothorax (100%), consolidations (90?100%), and varying sensitivities for nodules (60?100%) and emphysema (65?90%). Conclusion: The included studies found LD-CT to have high diagnostic accuracy in detection of honeycombing and bronchiectasis and ULD-CT to have high diagnostic accuracy for pneumothorax, consolidations and GGO. Summarizing evidence on diagnostic accuracy of LD- and ULD-CT for other chest pathology was not possible due to varying outcome measures, lack of precision estimates and heterogeneous study design and methodology.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [1] Combined Low-dose Simulation and Deep Learning for CT Denoising: Application in Ultra-low-dose Chest CT
    Ahn, Chulkyun
    Heo, Changyong
    Kim, Jong Hyo
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [2] Diagnostic accuracy of ultra-low-dose chest computed tomography in an emergency department
    Taekker, Maria
    Kristjansdottir, Bjorg
    Andersen, Michael B.
    Fransen, Maja L.
    Greisen, Pernille W.
    Laursen, Christian B.
    Mussmann, Bo
    Posth, Stefan
    Graumann, Ole
    ACTA RADIOLOGICA, 2022, 63 (03) : 336 - 344
  • [3] Diagnostic accuracy of ultra-low-dose CT colonography for the detection of colorectal polyps: a feasibility study
    Yasuda, Takaaki
    Honda, Tetsuro
    Utano, Kenichi
    Kato, Takashi
    Togashi, Kazutomo
    Yamaguchi, Shota
    Yasaka, Takahiro
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (08) : 831 - 839
  • [4] Diagnostic accuracy of ultra-low-dose CT colonography for the detection of colorectal polyps: a feasibility study
    Takaaki Yasuda
    Tetsuro Honda
    Kenichi Utano
    Takashi Kato
    Kazutomo Togashi
    Shota Yamaguchi
    Takahiro Yasaka
    Japanese Journal of Radiology, 2022, 40 : 831 - 839
  • [5] Diagnostic accuracy of ultra-low-dose CT for torsion measurement of the lower limb
    Gabriel Keller
    Saif Afat
    Marc-Daniel Ahrend
    Fabian Springer
    European Radiology, 2021, 31 : 3574 - 3581
  • [6] Diagnostic accuracy of ultra-low-dose CT for torsion measurement of the lower limb
    Keller, Gabriel
    Afat, Saif
    Ahrend, Marc-Daniel
    Springer, Fabian
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3574 - 3581
  • [7] Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature
    Rob, S.
    Bryant, T.
    Wilson, I.
    Somani, B. K.
    CLINICAL RADIOLOGY, 2017, 72 (01) : 11 - 15
  • [8] Ultra low-dose helical CT of the chest
    Nitta, N
    Takahashi, M
    Murata, K
    Morita, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 383 - 385
  • [9] URO - low-dose vs. ultra-low-dose CT in the diagnosis of urolithiasis
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (01): : 18 - 19
  • [10] Impact of Morphotype on Image Quality and Diagnostic Performance of Ultra-Low-Dose Chest CT
    Ortlieb, Anne-Claire
    Labani, Aissam
    Severac, Francois
    Jeung, Mi-Young
    Roy, Catherine
    Ohana, Mickael
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)