摘要
Coregistration of functional brain images across many subjects offers several experimental advantages and is widely used for studies in humans. Voxel-based coregistration methods require a high-quality 3-D template image, preferably one that corresponds to a published atlas. Template images are available for human, but we could not find an appropriate template for neuroimaging studies in baboon. Here we describe the formation of a T1-weighted structural MR template image and a PET blood flow template, derived from 9 and 7 baboons, respectively. Custom software aligns individual MR images to the MRI template; human supervision is needed only to initially estimate any gross rotational misalignment. In these aligned individual images, internal subcortical fiducial points correspond closely to a photomicrographic baboon atlas with an average error of 1.53 mm. Cortical test points showed a mean error of 1.99 min compared to the mean location for each point. Alignment of individual PET blood flow images directly to the PET template was compared to a two-step alignment process via each subject's MR image. The two transformations were identical within 0.41 mm, 0.54 degrees, and 1.0% (translation, rotation, and linear stretch; mean). These quantities provide a check on the validity of the alignment software as well as of the template images. The baboon structural AIR and blood flow PET templates are available on the Internet (purl.org/net/kbmd/b2k) and can be used as targets for any image registration software. (C) 2001 Academic Press.
引用
收藏
页码:736 / 743
页数:8
相关论文
共 41 条
[1]  
ANDERSSON JLR, 1995, J NUCL MED, V36, P1307
[2]  
[Anonymous], ATLAS STEREOTAXIQUE
[3]  
[Anonymous], J CEREB BLOOD FLOW M
[4]  
[Anonymous], 1968, STEREOTAXIC ATLAS BR
[5]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[6]  
2-G
[7]   Baboon basal ganglia stereotaxy using internal MRI landmarks: Validation and application to PET imaging [J].
Black, KJ ;
Gado, MH ;
Videen, TO ;
Perlmutter, JS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :881-886
[8]   A metric for testing the accuracy of cross-modality image registration: Validation and application [J].
Black, KJ ;
Videen, TO ;
Perlmutter, JS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) :855-861
[9]   Dopamine D1 agonist activates temporal lobe structures in primates [J].
Black, KJ ;
Hershey, T ;
Gado, MH ;
Perlmutter, JS .
JOURNAL OF NEUROPHYSIOLOGY, 2000, 84 (01) :549-557
[10]  
Black KJ, 1997, J NEUROSCI, V17, P3168