Kirschner wire (K-wire) fixation of fractures and dislocations of the hand and wrist is a common procedure. Of the 590 K-wire fixations performed on 236 patients, 36 (15.2%) experienced complications which included osteomyelitis, tendon rupture, nerve lesion, pin tract infection, pin loosening or migration. There were no deep soft-tissue pin infections or pyarthrosis. Technical failure, mainly when the procedure was performed by residents, and poor patient compliance were the major causes of complications. K-wire fixation is a simple but demanding procedure that cannot be left to an inexperienced resident. Elimination of technical failure, supervision in the operating room, close monitoring, prompt treatment upon discovery of a complication, and improvement of patient compliance can reduce the rate of complications.
引用
收藏
页码:527 / 530
页数:4
相关论文
共 10 条
[1]   COMPARISON OF INTERNAL-FIXATION TECHNIQUES IN METACARPAL FRACTURES [J].
BLACK, D ;
MANN, RJ ;
CONSTINE, R ;
DANIELS, AU .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (04) :466-472
[2]  
BOTTE MJ, 1992, CLIN ORTHOP RELAT R, P194
[3]  
DEHNE E, 1964, J Trauma, V4, P96, DOI 10.1097/00005373-196401000-00008
[4]   TENDON-RUPTURE AS A COMPLICATION OF SCREW FIXATION IN FRACTURES IN THE HAND - CASE-REPORT [J].
FAMBROUGH, RA ;
GREEN, DP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (05) :781-782
[5]   MECHANICAL STABILITY OF INTERNAL-FIXATION OF FRACTURED PHALANGES [J].
FYFE, IS ;
MASON, S .
HAND, 1979, 11 (01) :50-54
[6]  
Green S A, 1990, Instr Course Lect, V39, P219
[7]   Cardiac arrhythmia caused by a Kirschner wire inside the heart - An unusual complication of finger osteosynthesis [J].
Haapaniemi, TAT ;
Hermansson, US .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (03) :402-404
[8]  
SHAPIRO DB, 1994, HAND CLIN, V10, P1
[9]   KIRSCHNER WIRE PLACEMENT IN THE EMERGENCY ROOM - IS THERE A RISK [J].
STARKER, I ;
EATON, RG .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1995, 20B (04) :535-538
[10]  
STERN PJ, 1987, CLIN ORTHOP RELAT R, P59