Development of a 32-channel ASIC for an X-ray APD detector onboard the ISS

被引:2
|
作者
Arimoto, Makoto [1 ,2 ]
Harita, Shohei [2 ]
Sugita, Satoshi [2 ]
Yatsu, Yoichi [2 ]
Kawai, Nobuyuki [2 ]
Ikeda, Hirokazu [3 ]
Tomida, Hiroshi [3 ]
Isobe, Naoki [3 ]
Ueno, Shiro [4 ]
Mihara, Tatehiro [5 ]
Serino, Motoko [5 ]
Kohmura, Takayoshi [6 ]
Sakamoto, Takanori [7 ]
Yoshida, Atsumasa [7 ]
Tsunemi, Hiroshi [8 ]
Hatori, Satoshi [9 ]
Kume, Kyo [9 ]
Hasegawa, Takashi [9 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, 3-4-1 Ohkubo, Tokyo 1698555, Japan
[2] Tokyo Inst Technol, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
[3] ISAS, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2298510, Japan
[4] Japan Aerosp Explorat Agcy JAXA, ISAS, ISS Sci Project Off, 2-1-1 Sengen, Tsukuba, Ibaraki 3058505, Japan
[5] RIKEN, MAXI Team, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[6] Tokyo Univ Sci, Dept Phys, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[7] Aoyama Gakuin Univ, Dept Phys & Math, Coll Sci & Engn, Chuo Ku, 5-10-1 Fuchinobe, Sagamihara, Kanagawa 2525258, Japan
[8] Osaka Univ, Dept Earth & Space Sci, 1-1 Machikaneyama Cho, Toyonaka, Osaka 5600043, Japan
[9] Wakasa Wan Energy Res Ctr, 64-52-1 Nagatani, Tsuruga, Fukui 9140192, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2018年 / 882卷
关键词
ASIC; Low-noise; X-rays; APD; Radiation tolerance;
D O I
10.1016/j.nima.2017.09.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 mu m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e(-) + 1.5 e(-) /pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 degrees C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [1] A 32-Channel Readout ASIC for X-Ray Spectrometry and Tracking in the GAPS Experiment
    Manghisoni, Massimo
    Ghislotti, Luca
    Lazzaroni, Paolo
    Re, Valerio
    Riceputi, Elisa
    Ratti, Lodovico
    Fabris, Lorenzo
    Boezio, Mirko
    Zampa, Gianluigi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (01) : 96 - 105
  • [2] 32-channel ROIC for X-ray Imaging System
    Liu, Dan
    Gao, Feng
    Hao, Liguang
    Liao, Jianxin
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2017, : 843 - 846
  • [3] Development of the Hard X-ray Monitor onboard WF-MAXI
    Arimoto, Makoto
    Yatsu, Yoichi
    Kawai, Nobuyuki
    Ikeda, Hirokazu
    Harayama, Atsushi
    Takeda, Shin'ichiro
    Takahashi, Tadayuki
    Tomida, Hiroshi
    Ueno, Shiro
    Kimura, Masashi
    Mihara, Tatehiro
    Serino, Motoko
    Tsunemi, Hiroshi
    Yoshida, Atsumasa
    Sakamoto, Takanori
    Kohmura, Takayoshi
    Negoro, Hitoshi
    Ueda, Yoshihiro
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [4] Development of the analog ASIC for multi-channel readout X-ray CCD camera
    Nakajima, Hiroshi
    Matsuura, Daisuke
    Idehara, Toshihiro
    Anabuki, Naohisa
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Katayama, Haruyoshi
    Kitamura, Hisashi
    Uchihori, Yukio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 632 (01): : 128 - 132
  • [5] X-ray imaging with a silicon microstrip detector coupled to the RX64 ASIC
    Baldazzi, G
    Bollini, D
    Rodriguez, AEC
    Dabrowski, W
    Garcia, AD
    Gambaccini, M
    Giubellino, P
    Gombia, M
    Grybos, P
    Idzik, M
    Marzari-Chiesa, A
    Zetina, LMM
    Prino, F
    Ramello, L
    Sitta, M
    Swientek, K
    Taibi, A
    Tuffanelli, A
    Wheadon, R
    Wiacek, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 315 - 320
  • [6] Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution
    Thil, Ch.
    Baron, A. Q. R.
    Fajardo, P.
    Fischer, P.
    Graafsma, H.
    Rueffer, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 461 - 464
  • [7] An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments
    周杨帆
    李秋菊
    刘鹏
    樊磊
    徐伟
    陶冶
    李贞杰
    Chinese Physics C, 2017, (06) : 138 - 145
  • [8] An ultrafast front-end ASIC for APD array detectors in X-ray time-resolved experiments
    Zhou, Yang-Fan
    Li, Qiu-Ju
    Liu, Peng
    Fan, Lei
    Xu, Wei
    Tao, Ye
    Li, Zhen-Jie
    CHINESE PHYSICS C, 2017, 41 (06)
  • [9] A silicon strip detector coupled to the RX64 ASIC for X-ray diagnostic imaging
    Baldazzi, G
    Bollini, D
    Rodriguez, AEC
    Dabrowski, W
    Garcia, AD
    Gambaccini, M
    Giubellino, P
    Gombia, M
    Grybos, P
    Idzik, M
    Marzari-Chiesa, A
    Montano, LM
    Prino, F
    Ramello, L
    Sitta, M
    Swientek, K
    Taibi, A
    Tuffanelli, A
    Wheadon, R
    Wiacek, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 514 (1-3): : 206 - 214
  • [10] Multi-channel charge readout ASIC for X-ray detection
    Liu H.
    Xu L.
    Tian T.
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2021, 48 (04): : 97 - 102and112