Echocardiographic Assessment of Right Ventricular Volumes after Surgical Repair of Tetralogy of Fallot: Clinical Validation of a New Echocardiographic Method

被引:45
作者
Dragulescu, Andreea [1 ]
Grosse-Wortmann, Lars [1 ,2 ]
Fackoury, Cheryl [1 ]
Riffle, Sonja [3 ]
Waiss, Mary [3 ]
Jaeggi, Edgar [1 ]
Yoo, Shi-Joon [1 ,2 ]
Friedberg, Mark K. [1 ]
Mertens, Luc [1 ]
机构
[1] Hosp Sick Children, Labatt Family Heart Ctr, Div Cardiol, Dept Paediat, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[3] Ventripoint Inc, Seattle, WA USA
关键词
Echocardiography; Cardiac volume; Tetralogy of Fallot; Magnetic resonance imaging; PULMONARY VALVE-REPLACEMENT; 3-DIMENSIONAL ECHOCARDIOGRAPHY; CORRECTED TETRALOGY; DISEASE; OUTCOMES; ADULTS; SIZE;
D O I
10.1016/j.echo.2011.08.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Assessment of right ventricular (RV) volumes and function is important in patients after tetralogy of Fallot (TOF) repair. Currently, cardiac magnetic resonance imaging (MRI) is considered the clinical reference method for RV volume and function measurements. Three-dimensional (3D) knowledge-based reconstruction derived from two-dimensional echocardiographic imaging with magnetic tracking is a novel approach to RV volumetrics. The aim of this study was to assess the feasibility and reliability of this novel echocardiographic technique in patients after TOF repair. The accuracy of the method was assessed by comparison with measurements obtained by cardiac MRI. Methods: Thirty patients (mean age, 13.7 +/- 2.8 years) after TOF repair, referred for cardiac MRI, were included. Immediately after MRI, echocardiographic image acquisition was performed using a standard ultrasound scanner linked to a Ventripoint Medical Systems unit. Echocardiographic and MRI measurements were performed offline. Parameters analyzed were end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction. Intraobserver, interobserver, and intertechnique variability was assessed using Pearson's correlation analysis, coefficients of variation, and Bland-Altman analysis. Results: Echocardiographic two-dimensionally based 3D reconstruction was highly feasible, with low intraobserver and interobserver variability for EDV and slightly higher variability for ESV and ejection fraction. The 3D reconstruction values for EDV, ESV, and ejection fraction were correlated highly with MRI values, with low coefficients of variation. The agreement between both methods was high. Three-dimensional reconstruction slightly underestimated RV volumes, by 2.5% for EDV and 4.6% for ESV compared with MRI volumes. Conclusions: In patients after TOF repair, echocardiographic 3D reconstruction is highly feasible, with good reproducibility for measurements of RV EDV. There is good agreement with MRI measurements, with a small underestimation of RV volumes. The use of this method in clinical practice warrants further investigation. (J Am Soc Echocardiogr 2011; 24: 1191-8.)
引用
收藏
页码:1191 / 1198
页数:8
相关论文
共 21 条
  • [1] ESC Guidelines for the management of grown-up congenital heart disease (new version 2010)
    Baumgartner, Helmut
    Bonhoeffer, Philipp
    De Groot, Natasja M. S.
    de Haan, Fokko
    Deanfield, John Erik
    Galie, Nazzareno
    Gatzoulis, Michael A.
    Gohlke-Baerwolf, Christa
    Kaemmerer, Harald
    Kilner, Philip
    Meijboom, Folkert
    Mulder, Barbara J. M.
    Oechslin, Erwin
    Oliver, Jose M.
    Serraf, Alain
    Szatmari, Andras
    Thaulow, Erik
    Vouhe, Pascal R.
    Walma, Edmond
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (23) : 2915 - 2957
  • [2] Late pulmonary valve replacement after repair of tetralogy of Fallot
    Discigil, B
    Dearani, JA
    Puga, FJ
    Schaff, HV
    Hagler, DJ
    Warnes, CA
    Danielson, GK
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02) : 344 - 351
  • [3] Echocardiography for Assessment of Right Ventricular Volumes Revisited: A Cardiac Magnetic Resonance Comparison Study in Adults with Repaired Tetralogy of Fallot
    Greutmann, Matthias
    Tobler, Daniel
    Biaggi, Patric
    Mah, May Ling
    Crean, Andrew
    Oechslin, Erwin N.
    Silversides, Candice K.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 905 - 911
  • [4] Three-Dimensional Echocardiographic Assessment of Right Ventricular Volume and Function in Adult Patients With Congenital Heart Disease: Comparison With Magnetic Resonance Imaging
    Grewal, Jasmine
    Majdalany, David
    Syed, Imran
    Pellikka, Patricia
    Warnes, Carole A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (02) : 127 - 133
  • [5] Right ventricular function in cardiovascular disease, part I - Anatomy, physiology, aging, and functional assessment of the right ventricle
    Haddad, Francois
    Hunt, Sharon A.
    Rosenthal, David N.
    Murphy, Daniel J.
    [J]. CIRCULATION, 2008, 117 (11) : 1436 - 1448
  • [6] Right ventricular function in cardiovascular disease, Part II - Pathophysiology, clinical importance, and management of right ventricular failure
    Haddad, Francois
    Doyle, Ramona
    Murphy, Daniel J.
    Hunt, Sharon A.
    [J]. CIRCULATION, 2008, 117 (13) : 1717 - 1731
  • [7] COMPARISON OF ECHOCARDIOGRAPHIC METHODS WITH MAGNETIC-RESONANCE-IMAGING FOR ASSESSMENT OF RIGHT-VENTRICULAR FUNCTION IN CHILDREN
    HELBING, WA
    BOSCH, HG
    MALIEPAARD, C
    REBERGEN, SA
    VANDERGEEST, RJ
    HANSEN, B
    OTTENKAMP, J
    REIBER, JHC
    DEROOS, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08) : 589 - 594
  • [8] Late risk of outcomes for adults with repaired tetralogy of Fallot from an inception cohort spanning four decades
    Hickey, Edward J.
    Veldtman, Gruschen
    Bradley, Timothy J.
    Gengsakul, Aungkana
    Manlhiot, Cedric
    William, William G.
    Webb, Gary D.
    McCrindle, Brian W.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (01) : 156 - 164
  • [9] Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation
    Hubka, M
    Bolson, EL
    McDonald, JA
    Martin, RW
    Munt, B
    Sheehan, FH
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (02): : 111 - 118
  • [10] Right ventricle three-dimensional echography in corrected tetralogy of fallot: accuracy and variability
    Iriart, Xavier
    Montaudon, Michel
    Lafitte, Stephane
    Chabaneix, Julie
    Reant, Patricia
    Balbach, Thomas
    Houle, Helene
    Laurent, Francois
    Thambo, Jean-Benoit
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (06): : 784 - 792