Development of a method for automated and stable myocardial perfusion measurement using coronary X-ray angiography images

被引:5
作者
Sakaguchi, Takuya [1 ,2 ]
Ichihara, Takashi [3 ]
Natsume, Takahiro [3 ]
Yao, Jingwu [4 ]
Yousuf, Omair [5 ]
Trost, Jeffrey C. [5 ]
Lima, Joao A. C. [5 ]
George, Richard T. [5 ]
机构
[1] Toshiba Med Syst Corp, Otawara, Tochigi 3248550, Japan
[2] Tokyo Inst Technol, Tokyo 152, Japan
[3] Fujita Hlth Univ, Fac Radiol Technol, Sch Hlth Sci, Toyoake, Aichi 4701192, Japan
[4] Toshiba Med Res Inst USA, Vernon Hills, IL 60061 USA
[5] Johns Hopkins Univ, Div Cardiol, Dept Med, Sch Med, Baltimore, MD 21205 USA
关键词
Perfusion; Coronary angiography; Model analysis; Patlak plot; IMPULSE-RESPONSE ANALYSIS; TRANSIT-TIME MEASUREMENT; FLOW; INFARCTION; QUANTIFICATION; ANGIOPLASTY; REPERFUSION; MRI;
D O I
10.1007/s10554-015-0658-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to develop a method for automatic and stable determination of the optimal time range for fitting with a Patlak plot model in order to measure myocardial perfusion using coronary X-ray angiography images. A conventional two-compartment model is used to measure perfusion, and the slope of the Patlak plot is calculated to obtain a perfusion image. The model holds for only a few seconds while the contrast agent flows from artery to myocardium. Therefore, a specific time range should be determined for fitting with the model. To determine this time range, automation is needed for routine examinations. The optimal time range was determined to minimize the standard error between data points and their least-squares regression straight line in the Patlak plot. A total of 28 datasets were tested in seven porcine models. The new method successfully detected the time range when contrast agent flowed from artery to myocardium. The mean cross correlation in the linear regression analysis (R-2) was 0.996 +/- A 0.004. The mean length of the optimal time range was 3.61 +/- A 1.29 frames (2.18 +/- A 1.40 s). This newly developed method can automatically determine the optimal time range for fitting with the model.
引用
收藏
页码:905 / 914
页数:10
相关论文
共 23 条
[1]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[2]   DIGITAL SUBTRACTION ANGIOGRAPHIC IMAGING OF CORONARY FLOW RESERVE [J].
CUSMA, JT ;
TOGGART, EJ ;
FOLTS, JD ;
PEPPLER, WW ;
HANGIANDREOU, NJ ;
LEE, CS ;
MISTRETTA, CA .
CIRCULATION, 1987, 75 (02) :461-472
[3]   DIGITAL ANGIOGRAPHIC IMPULSE-RESPONSE ANALYSIS OF REGIONAL MYOCARDIAL PERFUSION - ESTIMATION OF CORONARY FLOW, FLOW RESERVE, AND DISTRIBUTION VOLUME BY COMPARTMENTAL TRANSIT-TIME MEASUREMENT IN A CANINE MODEL [J].
EIGLER, NL ;
SCHUHLEN, H ;
WHITING, JS ;
PFAFF, JM ;
ZEIHER, A ;
GU, S .
CIRCULATION RESEARCH, 1991, 68 (03) :870-880
[4]   DIGITAL ANGIOGRAPHIC IMPULSE-RESPONSE ANALYSIS OF REGIONAL MYOCARDIAL PERFUSION - LINEARITY, REPRODUCIBILITY, ACCURACY, AND COMPARISON WITH CONVENTIONAL INDICATOR DILUTION CURVE PARAMETERS IN PHANTOM AND CANINE MODELS [J].
EIGLER, NL ;
PFAFF, JM ;
ZEIHER, A ;
WHITING, JS ;
FORRESTER, JS .
CIRCULATION RESEARCH, 1989, 64 (05) :853-866
[5]   Relationship of TIMI myocardial perfusion grade to mortality after administration of thrombolytic drugs [J].
Gibson, CM ;
Cannon, CP ;
Murphy, SA ;
Ryan, KA ;
Mesley, R ;
Marble, SJ ;
McCabe, CH ;
Van de Werf, F ;
Braunwald, E .
CIRCULATION, 2000, 101 (02) :125-130
[6]   Coronary and myocardial angiography -: Angiographic assessment of both epicardial and myocardial perfusion [J].
Gibson, CM ;
Schömig, A .
CIRCULATION, 2004, 109 (25) :3096-3105
[7]   Myocardial perfusion characterization from contrast angiography spectral distribution [J].
Gil, Debora ;
Rodriguez-Leor, Oriol ;
Radeva, Petia ;
Mauri, Josepa .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (05) :641-649
[8]   Glomerular filtration rate measured by using triphasic helical CT with a two-point Patlak plot technique [J].
Hackstein, N ;
Wiegand, C ;
Rau, WS ;
Langheinrich, AC .
RADIOLOGY, 2004, 230 (01) :221-226
[9]   Angiographic assessment of reperfusion in acute myocardial infarction by myocardial blush grade [J].
Henriques, JPS ;
Zijlstra, F ;
van 't Hof, AWJ ;
de Boer, MJ ;
Dambrink, JHE ;
Gosselink, M ;
Hoorntje, JCA ;
Suryapranata, H .
CIRCULATION, 2003, 107 (16) :2115-2119
[10]  
Ichihara T, 2010, IEEE NUCL SCI S MED, DOI [10.1109/NSSMIC.2010.5874200, DOI 10.1109/NSSMIC.2010.5874200]