Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications

被引:55
作者
Jannis, D.
Hofer, C.
Gao, C.
Xie, X.
Beche, A.
Pennycook, T. J.
Verbeeck, J. [1 ]
机构
[1] Univ Antwerp, EMAT, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
基金
欧盟地平线“2020”;
关键词
Scanning transmission electron microscopy; 4D STEM; Low dose; Event based detection; PHASE-CONTRAST; ELECTRON;
D O I
10.1016/j.ultramic.2021.113423
中图分类号
TH742 [显微镜];
学科分类号
摘要
Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging.
引用
收藏
页数:9
相关论文
共 61 条
[41]   Efficient phase contrast imaging in STEM using a pixelated detector. Part 1: Experimental demonstration at atomic resolution [J].
Pennycook, Timothy J. ;
Lupini, Andrew R. ;
Yang, Hao ;
Murfitt, Matthew F. ;
Jones, Lewys ;
Nellist, Peter D. .
ULTRAMICROSCOPY, 2015, 151 :160-167
[42]   X-ray and gamma imaging with Medipix and Timepix detectors in medical research [J].
Procz, S. ;
Avila, C. ;
Fey, J. ;
Roque, G. ;
Schuetz, M. ;
Hamann, E. .
RADIATION MEASUREMENTS, 2019, 127
[43]   EXPERIMENTAL TESTS ON DOUBLE-RESOLUTION COHERENT IMAGING VIA STEM [J].
RODENBURG, JM ;
MCCALLUM, BC ;
NELLIST, PD .
ULTRAMICROSCOPY, 1993, 48 (03) :304-314
[44]   THE THEORY OF SUPERRESOLUTION ELECTRON-MICROSCOPY VIA WIGNER-DISTRIBUTION DECONVOLUTION [J].
RODENBURG, JM ;
BATES, RHT .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1992, 339 (1655) :521-553
[45]   The Editorial [J].
Rosenfeld, Anatoly ;
Silari, Marco ;
Campbell, Michael .
RADIATION MEASUREMENTS, 2020, 139
[46]   A pnCCD-based, fast direct single electron imaging camera for TEM and STEM [J].
Ryll, H. ;
Simson, M. ;
Hartmann, R. ;
Holl, P. ;
Huth, M. ;
Ihle, S. ;
Kondo, Y. ;
Kotula, P. ;
Liebel, A. ;
Mueller-Caspary, K. ;
Rosenauer, A. ;
Sagawa, R. ;
Schmidt, J. ;
Soltau, H. ;
Strueder, L. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[47]   Dynamic scan control in STEM: spiral scans [J].
Sang, Xiahan ;
Lupini, Andrew R. ;
Unocic, Raymond R. ;
Chi, Miaofang ;
Borisevich, Albina Y. ;
Kalinin, Sergei V. ;
Endeve, Eirik ;
Archibald, Richard K. ;
Jesse, Stephen .
ADVANCED STRUCTURAL AND CHEMICAL IMAGING, 2016, 2
[48]   Image registration of low signal-to-noise cryo-STEM data [J].
Savitzky, Benjamin H. ;
El Baggari, Ismail ;
Clement, Colin B. ;
Waite, Emily ;
Goodge, Berit H. ;
Baek, David J. ;
Sheckelton, John P. ;
Pasco, Christopher ;
Nair, Hari ;
Schreiber, Nathaniel J. ;
Hoffman, Jason ;
Admasu, Alemayehu S. ;
Kim, Jaewook ;
Cheong, Sang-Wook ;
Bhattacharya, Anand ;
Schlom, Darrell G. ;
McQueen, Tyrel M. ;
Hovden, Robert ;
Kourkoutis, Lena F. .
ULTRAMICROSCOPY, 2018, 191 :56-65
[49]   Atomic Resolution Defocused Electron Ptychography at Low Dose with a Fast, Direct Electron Detector [J].
Song, Jiamei ;
Allen, Christopher S. ;
Gao, Si ;
Huang, Chen ;
Sawada, Hidetaka ;
Pan, Xiaoqing ;
Warner, Jamie ;
Wang, Peng ;
Kirkland, Angus, I .
SCIENTIFIC REPORTS, 2019, 9 (1)
[50]   Timepix3: Temperature influence on X-ray measurements in counting mode with Si sensor [J].
Urban, Martin ;
Doubravova, Daniela .
RADIATION MEASUREMENTS, 2021, 141