Comparison of real time and malachite-green based loop-mediated isothermal amplification assays for the detection ofPlasmodium vivaxandP.falciparum

被引:18
作者
Barazorda, Keare A. [1 ,2 ]
Salas, Carole J. [1 ]
Bishop, Danett K. [1 ]
Lucchi, Naomi [3 ]
Valdivia, Hugo O. [1 ]
机构
[1] US Naval Med Res Unit 6 NAMRU 6, Dept Parasitol, Lima, Peru
[2] NGO Prisma, Lima, Peru
[3] Ctr Dis Control & Prevent, Div Parasit Dis & Malaria, Malaria Branch, Ctr Global Hlth, Atlanta, GA USA
来源
PLOS ONE | 2020年 / 15卷 / 06期
关键词
MALARIA; DIAGNOSIS; THAILAND; VIVAX;
D O I
10.1371/journal.pone.0234263
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The current context of malaria elimination requires urgent development and implementation of highly sensitive and specific methods for prompt detection and treatment of malaria parasites. Such methods should overcome current delays in diagnosis, allow the detection of low-density infections and address the difficulties in accessing remote endemic communities. In this study, we assessed the performance of the RealAmp and malachite-green loop mediated isothermal amplification (MG-LAMP) methodologies, using microscopy and conventional nested-PCR as reference techniques. Both LAMP techniques were performed for Plasmodium genus,P.falciparum, andP.vivaxidentification using 136 whole blood samples collected from three communities located in the Peruvian Amazon basin. Turnaround time and costs of performing the LAMP assays were estimated and compared to that of microscopy and nested-PCR. Using nested-PCR as reference standard, we calculated the sensitivity, specificity and 95% confidence interval (CI) for all methods. RealAmp had a sensitivity of 92% (95% CI: 85-96.5%) and specificity of 100% (95% CI: 89.1-100%) for species detection; sensitivity and specificity of MG-LAMP were 94% (95% CI: 87.5-97.8%) and 100% (89.1-100%), respectively. Whereas microscopy showed 88.1% sensitivity (95% CI: 80.2-93.7%) and 100% specificity (95%: 89.1-100%). The turnaround time and costs of performing the LAMP assays were lower compared to those associated with nested-PCR but higher than those associated with microscopy. The two LAMP assays were shown to be more sensitive and simple to implement than microscopy. Both LAMP methodologies could be used as large-scale screening tests, but the MG-LAMP assay uses a simple, portable heat-block while the RealAmp requires a RealAmp machine or a real-time PCR machine. This makes the MG-LAMP an appropriate choice for malaria surveillance studies in endemic sites. Use of LAMP tests in active case detection ofPlasmodiumparasites could help to detect positive malaria cases early.
引用
收藏
页数:11
相关论文
共 23 条
  • [1] [Anonymous], WORLD MALARIA REPORT
  • [2] Epidemiology of Disappearing Plasmodium vivax Malaria: A Case Study in Rural Amazonia
    Barbosa, Susana
    Gozze, Amanda B.
    Lima, Nathalia F.
    Batista, Camilla L.
    Bastos, Melissa da Silva
    Nicolete, Vanessa C.
    Fontoura, Pablo S.
    Goncalves, Raquel M.
    Viana, Susana Ariane S.
    Menezes, Maria Jose
    Scopel, Kezia Katiani G.
    Cavasini, Carlos E.
    Malafronte, Rosely dos Santos
    da Silva-Nunes, Monica
    Vinetz, Joseph M.
    Castro, Marcia C.
    Ferreira, Marcelo U.
    [J]. PLOS NEGLECTED TROPICAL DISEASES, 2014, 8 (08):
  • [3] CDC (Centro Nacional de Epidemiologia PyCdE, 2018, INC MAL DISTR
  • [4] Expert Panel on Neurologic Imaging, 2017, J AM COLL RADIOL, V14, pS550
  • [5] A Large Proportion of P. falciparum Isolates in the Amazon Region of Peru Lack pfhrp2 and pfhrp3: Implications for Malaria Rapid Diagnostic Tests
    Gamboa, Dionicia
    Ho, Mei-Fong
    Bendezu, Jorge
    Torres, Katherine
    Chiodini, Peter L.
    Barnwell, John W.
    Incardona, Sandra
    Perkins, Mark
    Bell, David
    McCarthy, James
    Cheng, Qin
    [J]. PLOS ONE, 2010, 5 (01):
  • [6] Plasmodium vivax and mixed infections are associated with severe malaria in children:: A prospective cohort study from Papua New Guinea
    Genton, Blaise
    D'Acremont, Valerie
    Rare, Lawrence
    Baea, Kay
    Reeder, John C.
    Alpers, Michael P.
    Mueller, Ivo
    [J]. PLOS MEDICINE, 2008, 5 (06) : 881 - 889
  • [7] Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue
    Goto, Motoki
    Honda, Eiichi
    Ogura, Atsuo
    Nomoto, Akio
    Hanaki, Ken-Ichi
    [J]. BIOTECHNIQUES, 2009, 46 (03) : 167 - +
  • [8] Malaria Diagnosis across the International Centers of Excellence for Malaria Research: Platforms, Performance, and Standardization
    Kobayashi, Tamaki
    Gamboa, Dionicia
    Ndiaye, Daouda
    Cui, Liwang
    Sutton, Patrick L.
    Vinetz, Joseph M.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (03) : 99 - 109
  • [9] Field evaluation of malaria malachite green loop-mediated isothermal amplification in health posts in Roraima state, Brazil
    Kudyba, Heather M.
    Louzada, Jaime
    Ljolje, Dragan
    Kudyba, Karl A.
    Muralidharan, Vasant
    Oliveira-Ferreira, Joseli
    Lucchi, Naomi W.
    [J]. MALARIA JOURNAL, 2019, 18 (1)
  • [10] Expanding the malaria molecular diagnostic options: opportunities and challenges for loop-mediated isothermal amplification tests for malaria control and elimination
    Lucchi, Naomi W.
    Ndiaye, Daouda
    Britton, Sumudu
    Udhayakumar, Venkatachalam
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2018, 18 (02) : 195 - 203