Comparative study of melting and solidification processes in different configurations of shell and tube high temperature latent heat storage system

被引:33
作者
Riahi, Soheila [1 ]
Saman, Wasim Y. [1 ]
Bruno, Frank [1 ]
Belusko, Martin [1 ]
Tay, N. H. S. [2 ]
机构
[1] Univ Australia, Barbara Hardy Inst, Mawson Lakes, SA 5095, Australia
[2] Newcastle Univ Singapore, Sch Mech & Syst Engn, SIT Bldg & Nanyang Polytech, Singapore 567739, Singapore
关键词
Modeling phase change; Latent heat storage; Parallel flow; Melting; Solidification; Counter flow; THERMAL-ENERGY STORAGE; PHASE-CHANGE-MATERIAL; NATURAL-CONVECTION; NUMERICAL-ANALYSIS; POWER-PLANT; PERFORMANCE; DESIGN; FINS; SIMULATION; PCMS;
D O I
10.1016/j.solener.2017.04.061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of parallel and counter flow configurations of a shell and tube heat exchanger used as a latent heat thermal storage system was investigated. The comparative analysis of the melting and solidification processes (charging and discharging) in the vertical and horizontal orientations of counter and parallel flow was included in this study to make the results conclusive for the purpose of design of the storage system to be used in a concentrated solar power (CSP) plant. In this analyses, taking into account natural convection, numerical calculations were performed using ANSYS Fluent. The vertical parallel flow configuration shows 12% higher effectiveness compared to the counter flow for the charging and discharging processes. A higher rate of phase change occurs for both the charging and discharging processes in a parallel flow configuration, as a higher fraction of phase change material (PCM) is exposed to the heat transfer fluid inlet temperature compared to the counter flow. However, a lower temperature gradient and nearly constant effectiveness for a longer period of time are observed in the counter flow arrangement due to the higher rate of natural convection. An interesting result is the higher rate of natural convection in the horizontal orientation compared to the vertical one due to the Benard convection phenomenon, despite the fact that Ra is higher in the vertical orientations (10(10) >10(7)). The horizontal counter flow and parallel flow configurations show on average 10% higher effectiveness for the charging process which is constant for a longer period during the process compared to the vertical configurations whereas the horizontal arrangement during the discharging process improves the effectiveness by about 2% due to the minor role of natural convection. The horizontal configurations provide a more uniform phase change process with the lowest peak temperatures (in the melting processes) and temperature gradient which are correlated with the highest second law efficiency and exergy recovery. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 374
页数:12
相关论文
共 43 条
[1]  
[Anonymous], 2015, SOL ENERGY
[2]  
[Anonymous], 2015, ANSYS FLUENT 15 0 US
[3]  
[Anonymous], 2015, DESIGNMODELER US GUI
[4]   Numerical and experimental study of melting in a spherical shell [J].
Assis, E. ;
Katsman, L. ;
Ziskind, G. ;
Letan, R. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (9-10) :1790-1804
[5]   Numerical and Experimental Study of Solidification in a Spherical Shell [J].
Assis, E. ;
Ziskind, G. ;
Letan, R. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2009, 131 (02) :1-5
[6]   Numerical evaluation of a triple concentric-tube latent heat thermal energy storage [J].
Basal, Birol ;
Unal, Ahmet .
SOLAR ENERGY, 2013, 92 :196-205
[7]  
Bejan A, 2008, DESIGN CONSTRUCTAL T, P249
[8]  
Bejan A., 2008, DESIGN CONSTRUCTAL T, P215
[9]  
Bejan A., 2013, Convection Heat Transfer, V4, P233
[10]   Enhanced performances of macro-encapsulated phase change materials (PCMs) by intensification of the internal effective thermal conductivity [J].
Calvet, Nicolas ;
Py, Xavier ;
Olives, Regis ;
Bedecarrats, Jean-Pierre ;
Dumas, Jean-Pierre ;
Jay, Frederic .
ENERGY, 2013, 55 :956-964