An automated quasi-continuous capillary refill timing device

被引:27
作者
Blaxter, L. L. [1 ]
Morris, D. E. [1 ]
Crowe, J. A. [1 ]
Henry, C. [2 ]
Hill, S. [2 ]
Sharkey, D. [2 ]
Vyas, H. [2 ]
Hayes-Gill, B. R. [1 ]
机构
[1] Univ Nottingham, Fac Engn, Elect Syst & Opt Res Div, Nottingham NG7 2RD, England
[2] Queens Med Ctr, Acad Child Hlth, Sch Med, Nottingham NG7 2UH, England
基金
英国医学研究理事会;
关键词
capillary refill time; automation; sensor; monitoring; TIME; TEMPERATURE; SYSTEM;
D O I
10.1088/0967-3334/37/1/83
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n = 30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5 degrees C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies.
引用
收藏
页码:83 / 99
页数:17
相关论文
共 27 条
[1]   Impact of patient and environmental factors on capillary refill time in adults [J].
Anderson, Bronwyn ;
Kelly, Anne-Maree ;
Kerr, Debra ;
Clooney, Megan ;
Jolley, Damien .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (01) :62-65
[2]  
[Anonymous], 2010, U NOTTINGHAM CODE RE
[3]  
BARAFF LJ, 1993, PEDIATRICS, V92, P723
[4]  
Bezzerides V, 2010, US Patent App, Patent No. [13/ 518,452, 13518452]
[5]   ADVERSE LIGHTING CONDITION EFFECTS ON THE ASSESSMENT OF CAPILLARY REFILL [J].
BROWN, LH ;
PRASAD, NH ;
WHITLEY, TW .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1994, 12 (01) :46-47
[6]   TRAUMA SCORE [J].
CHAMPION, HR ;
SACCO, WJ ;
CARNAZZO, AJ ;
COPES, W ;
FOUTY, WJ .
CRITICAL CARE MEDICINE, 1981, 9 (09) :672-676
[7]   LIGHT EMITTING DIODE SKIN REFLECTANCE OXIMETER [J].
COHEN, A ;
WADSWORTH, N .
MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (03) :385-+
[8]   STUDIES ON GANGRENE FOLLOWING COLD INJURY .6. CAPILLARY BLOOD FLOW AFTER COLD INJURY, THE EFFECTS OF RAPID WARMING, AND SYMPATHETIC BLOCK [J].
CRISMON, JM ;
FUHRMAN, FA .
JOURNAL OF CLINICAL INVESTIGATION, 1947, 26 (03) :468-475
[9]   The pediatric early warning system score: A severity of illness score to predict urgent medical need in hospitalized children [J].
Duncan, Heather ;
Hutchison, James ;
Parshuram, Christopher S. .
JOURNAL OF CRITICAL CARE, 2006, 21 (03) :271-278
[10]   THE VALIDITY AND PRACTICALITY OF SUN-REACTIVE SKIN TYPE-I THROUGH TYPE-VI [J].
FITZPATRICK, TB .
ARCHIVES OF DERMATOLOGY, 1988, 124 (06) :869-871