A clinical study for the durability of oxygenators on cardiopulmonary support

被引:0
|
作者
Usui, A
Murakami, F
Ooshima, H
Tomita, Y
Yoshida, K
Hibi, M
Kawamura, M
Muras, M
机构
[1] OWARI PREFECTURAL HOSP,CARDIOVASC CTR SURG,ICHINOMIYA,JAPAN
[2] NAGOYA UNIV,SCH MED,DEPT THORAC SURG,NAGOYA,AICHI 466,JAPAN
关键词
oxygenator; cardiopulmonary support; percutaneous cardiopulmonary support;
D O I
10.1111/j.1525-1594.1997.tb03740.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiopulmonary support (CPS) requires durability of the oxygenator. The life span of the oxygenator is affected by various clinical factors, including patient condition, perfusion condition, and equipment usage. Predictors for the durability of oxygenators were evaluated clinically in this study. Thirty-two patients, who had undergone CPS during the last 3 years in our institute were assigned to this study. Fifty oxygenators had been used (Capiox SX in 19, CB Maxima in 23, and AL-6000 in 8). Significant predictors for the durability of oxygenators were evaluated by nonparametric survival analysis and proportional hazards regression analysis. Univariate regression analysis revealed 6 significant predictors for the life span of oxygenators. These were the oxygenator type, type of centrifugal pump, acidosis with blood pH less than 7.35, base excess less than -5, blood glutamic-oxaloacetic transaminase (GOT) levels greater than 1,000 IU, and blood lactate dehydrogenase (LDH) levels greater than 3,000 IU. After multivariate analysis, there remained only 2 significant predictors. An oxygenator used with a noncoated CPS system (Capiox SX with Capiox EBS) proved to have a significantly shorter life span than one used with a heparin-coated system (CB Maxima or AL-6000 with CB BP-80) (hazards ratio, 3.588, p = 0.0065). Patient conditions, which revealed acidosis with less than -5 of base excess, significantly shortened the life of the oxygenator (hazards ratio, 3.595, p = 0.0188).
引用
收藏
页码:772 / 778
页数:7
相关论文
共 50 条
  • [1] Heparin coating extends the durability of oxygenators used for cardiopulmonary support
    Usui, A
    Hiroura, M
    Kawamura, M
    ARTIFICIAL ORGANS, 1999, 23 (09) : 840 - 844
  • [2] Clinical experience of percutaneous cardiopulmonary support
    Sasako, Y
    Nakatani, T
    Nonogi, H
    Miyazaki, S
    Kito, Y
    Takano, H
    Kawashima, Y
    ARTIFICIAL ORGANS, 1996, 20 (06) : 733 - 736
  • [3] Clinical evaluation of contemporary oxygenators
    Stanzel, Roger D. P.
    Henderson, Mark
    PERFUSION-UK, 2016, 31 (01): : 15 - 25
  • [4] The effects of single and dual reservoired oxygenators on inflammatory response in cardiopulmonary bypass
    Calisal, Mehmet Alper
    Bugra, Onursal
    Simsek, Erdal
    Erdem, Kemalettin
    Daglar, Bahadir
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 21 (02): : 305 - 312
  • [5] PERCUTANEOUS CARDIOPULMONARY SUPPORT (PCPS)
    URBANEK, P
    BOCK, H
    VICOL, C
    CARDIOLOGY, 1994, 84 (03) : 216 - 221
  • [6] Clinical evaluation of five commercially available adult oxygenators in terms of pressure drop during normothermic and hypothermic cardiopulmonary bypass
    Ji, Bingyang
    Wang, Hongyue
    Miao, Na
    Xing, Jialin
    Liu, Wei
    Liu, Ruifang
    Long, Cun
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (05) : 310 - 316
  • [7] Humoral immune response and coated or uncoated oxygenators during cardiopulmonary bypass surgery
    Karakisi, Sedat Ozan
    Kunt, Ayse Gul
    Bozok, Sahin
    Cankaya, Idil
    Kocakulak, Mustafa
    Musabak, Ugur
    Sargon, Mustafa Fevzi
    Ergene, Saban
    Ilhan, Gokhan
    Karamustafa, Hakan
    Tufekci, Nebiye
    Sener, Erol
    CARDIOVASCULAR JOURNAL OF AFRICA, 2016, 27 (04) : 242 - 245
  • [8] Impact of Distinct Oxygenators on Pulsatile Energy Indicators in an Adult Cardiopulmonary Bypass Model
    Griep, Lonneke M.
    van Barneveld, Laurentius J. M.
    Simons, Antoine P.
    Boer, Christa
    Weerwind, Patrick W.
    ARTIFICIAL ORGANS, 2017, 41 (02) : E15 - E25
  • [9] Clinical experiences of percutaneous cardiopulmonary support: Its effectiveness and limit
    Orime, Y
    Shiono, M
    Hata, H
    Yagi, S
    Tsukamoto, S
    Okumura, H
    Nakata, K
    Kimura, S
    Sezai, A
    Sezai, Y
    ARTIFICIAL ORGANS, 1998, 22 (06) : 498 - 501
  • [10] Refurbishment of Extracorporeal Life Support Oxygenators in the Context of In Vitro Testing
    Strudthoff, Lasse J.
    Hesselmann, Felix
    Clauser, Johanna C.
    Arens, Jutta
    ASAIO JOURNAL, 2023, 69 (10) : 924 - 931