Performance of a Fully Automatic Lesion Detection System for Breast DCE-MRI

被引:46
作者
Vignati, Anna [1 ]
Giannini, Valentina [1 ,2 ]
De Luca, Massimo [1 ]
Morra, Lia [3 ]
Persano, Diego [3 ]
Carbonaro, Luca A. [4 ,5 ]
Bertotto, Ilaria [1 ]
Martincich, Laura [1 ]
Regge, Daniele [1 ]
Bert, Alberto [3 ]
Sardanelli, Francesco [4 ,5 ]
机构
[1] IRCC Inst Canc Res & Treatment, Dept Radiol, Candiolo, Italy
[2] Politecn Torino, Dept Elect, Turin, Italy
[3] im3D SpA, Turin, Italy
[4] Univ Milan, Dipartimento Sci Med Chirurg, Milan, Italy
[5] IRCCS Policlin San Donato, Milan, Italy
关键词
computer aided detection (CAD); breast cancer; DCE-MRI; automatic detection; fat-saturation; DIFFERENTIAL-DIAGNOSIS; DYNAMIC MRI; SEGMENTATION; THRESHOLDS;
D O I
10.1002/jmri.22680
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To describe and test a new fully automatic lesion detection system for breast DCE-MRI. Materials and Methods: Studies were collected from two institutions adopting different DCE-MRI sequences, one with and the other one without fat-saturation. The detection pipeline consists of (i) breast segmentation, to identify breast size and location; (ii) registration, to correct for patient movements; (iii) lesion detection, to extract contrast-enhanced regions using a new normalization technique based on the contrast-uptake of mammary vessels; (iv) false positive (FP) reduction, to exclude contrast-enhanced regions other than lesions. Detection rate (number of system-detected malignant and benign lesions over the total number of lesions) and sensitivity (system-detected malignant lesions over the total number of malignant lesions) were assessed. The number of FPs was also assessed. Results: Forty-eight studies with 12 benign and 53 malignant lesions were evaluated. Median lesion diameter was 6 mm (range, 5-15 mm) for benign and 26 mm (range, 575 mm) for malignant lesions. Detection rate was 58/65 (89%; 95% confidence interval [CI] 79%-95%) and sensitivity was 52/53 (98%; 95% CI 90%-99%). Mammary median FPs per breast was 4 (1st-3rd quartiles 3-7.25). Conclusion: The system showed promising results on MR datasets obtained from different scanners producing fat-sat or non-fat-sat images with variable temporal and spatial resolution and could potentially be used for early diagnosis and staging of breast cancer to reduce reading time and to improve lesion detection. Further evaluation is needed before it may be used in clinical practice.
引用
收藏
页码:1341 / 1351
页数:11
相关论文
共 37 条
[1]  
American College of Radiology (ACR), 2008, ACR PRACT GUID PERF
[2]  
Antiga L., 2007, INSIGHT J JUL
[3]  
Bankman I.N., 2006, RECENT ADV BREAST IM, P723
[4]   Cancer incidence and mortality in Europe, 2004 [J].
Boyle, P ;
Ferlay, J .
ANNALS OF ONCOLOGY, 2005, 16 (03) :481-488
[5]  
Broyden C.G., 1970, IMA J APPL MATH, V6, P76, DOI [10.1093/imamat/6.1.76, DOI 10.1093/IMAMAT/6.1.76]
[6]   Handling a High Relaxivity Contrast Material for Dynamic Breast MR Imaging Using Higher Thresholds for the Initial Enhancement [J].
Carbonaro, Luca A. ;
Verardi, Nicola ;
Di Leo, Giovanni ;
Sardanelli, Francesco .
INVESTIGATIVE RADIOLOGY, 2010, 45 (03) :114-120
[7]  
Chakraborti K., 2005, Indian Journal of Radiology and Imaging, V15, P381, DOI DOI 10.4103/0971-3026.29160
[8]   Differential Diagnosis of Breast Lesions 5 mm or Less: Is There a Role for Magnetic Resonance Imaging? [J].
Dietzel, Matthias ;
Baltzer, Pascal A. ;
Vag, Tibor ;
Groeschel, Tobias ;
Gajda, Mieczyslaw ;
Camara, Oumar ;
Kaiser, Werner A. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (03) :456-464
[9]   Breast MR segmentation and lesion detection with cellular neural networks and 3D template matching [J].
Ertas, Goekhan ;
Guelcuer, H. Oezcan ;
Osman, Onur ;
Ucan, Osman N. ;
Tunaci, Mehtap ;
Dursun, Memduh .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (01) :116-126
[10]   MR imaging and proton spectroscopy of the breast: How to select the images useful to convey the diagnostic message [J].
Fausto A. ;
Magaldi A. ;
Babaei Paskeh B. ;
Menicagli L. ;
Lupo E.N. ;
Sardanelli F. .
La radiologia medica, 2007, 112 (7) :1060-1068